There is a pressing need in international security policy to better understand the future landscape of radiological and nuclear (RN) dangers and how best to target resources to affect their reduction. The highly dynamic nature of the global geopolitical, social and technological environments means that ther e are many potential forces that might influence the magnitude of current RN dangers, especially those emanating from non-state actors like terrorists. These include: the spread of radical ideology, the growth of civilian nuclear energy in politically unstable regions of the world, the potential for increased nuclear proliferation in those regions, the continued dissemination of WMD information in open sources, and advances in technology that may facilitate VNSA violent non-state actor (VNSA) RN programs. Therefore, this study’s main purpose is to provide an overview of the high level future drivers of RN terrorism as they pertain to the motives and intentions1 of known and potential adversaries. A central approach of this study is to ask the question: Why have there not been more attempts to engage in RN terrorism and, particularly in the case of radiological terrorism, why have those attempts that have been made not been more successful? Once the probable factors that have curtailed the RN terrorist threat thus far have been identified, the study will consider whether there are extant and emerging drivers that might bring about changes in these mitigating factors over the next 10 years. Finally, the study attempts to assess the future dangers of RN terrorism based on these potential changes and what policy approaches can be implemented to reduce the threat, particularly the role of deterrence and dissuasion.
Mylar® polymer is a bi-axially oriented polyethylene terephthalate (PET) polymer film used widely as a dielectric, specifically in capacitors. The dielectric characteristics of Mylar have been well studied and documented over the years; however, many of the mechanisms responsible for dielectric breakdown and failure are not understood for modified versions of the material. Previous studies on Mylar confirm that factors such as temperature, humidity, and voltage ramp rates can also have a significant effect on the dielectric properties and measurement of the dielectric properties. This study seeks to determine how dielectric properties, including permittivity, dielectric loss, and breakdown strength, are affected by doping of the polymer. To do this, two types of Mylar films, virgin film and film doped with a small-molecule electron-acceptor, are tested. Both types of materials are tested under a variety of environmental and experimental conditions, including testing at elevated temperatures, varying relative humidity, and varying ramp rates in dielectric breakdown testing. Analysis of permittivity, dielectric loss, and breakdown strength will be presented comparing virgin and doped Mylar to gain insight into the effects of doping with electron-acceptor molecules on dielectric properties under these varying environmental and test conditions.
This work will focus on the characterization of NTOF detectors fielded on ICF experiments conducted at the Z-experimental facility with emphasis on the MagLif and gas puff campaigns. Three experiments have been proposed. The first experiment will characterize the response of the PMT with respect to the amplitude and width of signals produced by single neutron events. A second experiment will characterize the neutron transit time through the scintillator and the third is to characterize the pulse amplitude for a very specific range of neutron induced charged particle interactions within the scintillator. These experiments will cover incident neutron energies relevant to D-D and D-T fusion reactions. These measurements will be taken as a function of detector bias to cover the entire dynamic range of the detector. Throughout the characterization process, the development of a predictive capability is desired. A new post processing code has been proposed that will calculate a neutron time-of-flight spectrum in units of MeVee. This code will couple the experimentally obtained values and the results obtained with the Monte Carlo code MCNP6. The motivation of this code is to correct for geometry issues when transferring the calibration results from a light lab setting to the Zenvironment. This capability will be used to develop a hypothetical design of LOS270 such that more favorable neutron measurements, requiring less correction, can be made in the future.
This report describes the development of ultra-short pulse laser (USPL) induced terahertz (THz) radiation to image electronic plasmas during electrical breakdown. The technique uses three pulses from two USPLs to (1) trigger the breakdown, (2) create a 2 picosecond (ps, 10 -12 s), THz pulse to illuminate the breakdown, and (3) record the THz image of the breakdown. During this three year internal research program, sub-picosecond jitter timing for the lasers, THz generation, high bandwidth (BW) diagnostics, and THz image acquisition was demonstrated. High intensity THz radiation was optically-induced in a pulse-charged gallium arsenide photoconductive switch. The radiation was collected, transported, concentrated, and co-propagated through an electro-optic crystal with an 800 nm USPL pulse whose polarization was rotated due to the spatially varying electric field of the THz image. The polarization modulated USPL pulse was then passed through a polarizer and the resulting spatially varying intensity was detected in a high resolution digital camera. Single shot images had a signal to noise of %7E3:1. Signal to noise was improved to %7E30:1 with several experimental techniques and by averaging the THz images from %7E4000 laser pulses internally and externally with the camera and the acquisition system (40 pulses per readout). THz shadows of metallic films and objects were also recorded with this system to demonstrate free-carrier absorption of the THz radiation and improve image contrast and resolution. These 2 ps THz pulses were created and resolved with 100 femtosecond (fs, 10 -15 s) long USPL pulses. Thus this technology has the capability to time-resolve extremely fast repetitive or single shot phenomena, such as those that occur during the initiation of electrical breakdown. The goal of imaging electrical breakdown was not reached during this three year project. However, plans to achieve this goal as part of a follow-on project are described in this document. Further modifications to improve the THz image contrast and resolution are proposed, and after they are made, images of photo-induced carriers in gallium arsenide and silicon will be acquired to evaluate image sensitivity versus carrier density. Finally electrical breakdown will be induced with the first USPL pulse, illuminated with THz radiation produced with the second USPL pulse and recorded with the third USPL pulse.
The temporal evolution of spectral lines from microplasma devices (MD) was studied, including impurity transitions. Long-wavelength emission diminishes more rapidly than deep UV with decreasing pulse width and RF operation. Thus, switching from DC to short pulsed or RF operation, UV emissions can be suppressed, allowing for real-time tuning of the ionization energy of a microplasma photo-ionization source, which is useful for chemical and atomic physics. Scaling allows MD to operate near atmospheric pressure where excimer states are efficiently created and emit down to 65 nm; laser emissions fall off below 200 nm, making MD light sources attractive for deep UV use. A first fully-kinetic three-dimensional model was developed that explicitly calculates electron-energy distribution function. This, and non-continuum effects, were studied with the model and how they are impacted by geometry and transient or DC operation. Finally, a global non-dimensional model was developed to help explain general trends MD physics.
Sandia's Dakota software (available at http://dakota.sandia.gov) supports science and engineering transformation through advanced exploration of simulations. Specifically it manages and analyzes ensembles of simulations to provide broader and deeper perspective for analysts and decision makers. This enables them to enhance understanding of risk, improve products, and assess simulation credibility.
Water is the backbone of our economy - safe and adequate supplies of water are vital for agriculture, industry, recreation, and human consumption. While our supply of water today is largely safe and adequate, we as a nation face increasing water supply challenges in the form of extended droughts, demand growth due to population increase, more stringent health-based regulation, and competing demands from a variety of users. To meet these challenges in the coming decades, water treatment technologies, including desalination, will contribute substantially to ensuring a safe, sustainable, affordable, and adequate water supply for the United States. This overview documents Sandia National Laboratories' (SNL, or Sandia) Water Treatment Program which focused on the development and demonstration of advanced water purification technologies as part of the larger Sandia Water Initiative. Projects under the Water Treatment Program include: (1) the development of desalination research roadmaps (2) our efforts to accelerate the commercialization of new desalination and water treatment technologies (known as the 'Jump-Start Program),' (3) long range (high risk, early stage) desalination research (known as the 'Long Range Research Program'), (4) treatment research projects under the Joint Water Reuse & Desalination Task Force, (5) the Arsenic Water Technology Partnership Program, (6) water treatment projects funded under the New Mexico Small Business Administration, (7) water treatment projects for the National Energy Technology Laboratory (NETL) and the National Renewable Energy Laboratory (NREL), (8) Sandia- developed contaminant-selective treatment technologies, and finally (9) current Laboratory Directed Research and Development (LDRD) funded desalination projects.
Containment/Surveillance (C/S) measures are critical to any verification regime in order to maintain Continuity of Knowledge (CoK). The Ceramic Seal project is research into the next generation technologies to advance C/S, in particular improving security and efficiency. The Ceramic Seal is a small form factor loop seal with improved tamper-indication including a frangible seal body, tamper planes, external coatings, and electronic monitoring of the seal body integrity. It improves efficiency through a self-securing wire and in-situ verification with a handheld reader. Sandia National Laboratories (SNL) and Savannah River National Laboratory (SRNL), under sponsorship from the U.S. National Nuclear Security Administration (NNSA) Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D), have previously designed and have now fabricated and tested Ceramic Seals. Tests have occurred at both SNL and SRNL, with different types of tests occurring at each facility. This interim report will describe the Ceramic Seal prototype, the design and development of a handheld standalone reader and an interface to a data acquisition system, fabrication of the seals, and results of initial testing.
This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users' Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce . This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users' Guide [1] . The information herein is subject to change without notice. Copyright c 2002-2016 Sandia Corporation. All rights reserved. Acknowledgements The BSIM Group at the University of California, Berkeley developed the BSIM3, BSIM4, BSIM6, BSIM-CMG and BSIM-SOI models. The BSIM3 is Copyright c 1999, Regents of the University of California. The BSIM4 is Copyright c 2006, Regents of the University of California. The BSIM6 is Copyright c 2015, Regents of the University of California. The BSIM-CMG is Copyright c 2012 and 2016, Regents of the University of California. The BSIM-SOI is Copyright c 1990, Regents of the University of California. All rights reserved. The Mextram model has been developed by NXP Semiconductors until 2007, Delft University of Technology from 2007 to 2014, and Auburn University since April 2015. Copyrights c of Mextram are with Delft University of Technology, NXP Semiconductors and Auburn University. The MIT VS Model Research Group developed the MIT Virtual Source (MVS) model. Copyright c 2013 Massachusetts Institute of Technology (MIT). The EKV3 MOSFET model was developed by the EKV Team of the Electronics Laboratory-TUC of the Technical University of Crete. Trademarks Xyce TM Electronic Simulator and Xyce TM are trademarks of Sandia Corporation. Orcad, Orcad Capture, PSpice and Probe are registered trademarks of Cadence Design Systems, Inc. Microsoft, Windows and Windows 7 are registered trademarks of Microsoft Corporation. Medici, DaVinci and Taurus are registered trademarks of Synopsys Corporation. Amtec and TecPlot are trademarks of Amtec Engineering, Inc. All other trademarks are property of their respective owners. Contacts World Wide Web http://xyce.sandia.gov https://info.sandia.gov/xyce (Sandia only) Email xyce@sandia.gov (outside Sandia) xyce-sandia@sandia.gov (Sandia only) Bug Reports (Sandia only) http://joseki-vm.sandia.gov/bugzilla http://morannon.sandia.gov/bugzilla
This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been de- signed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: Capability to solve extremely large circuit problems by supporting large-scale parallel com- puting platforms (up to thousands of processors). This includes support for most popular parallel and serial computers. A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one to develop new types of analysis without requiring the implementation of analysis-specific device models. Device models that are specifically tailored to meet Sandia's needs, including some radiation- aware devices (for Sandia users only). Object-oriented code design and implementation using modern coding practices. Xyce is a parallel code in the most general sense of the phrase -- a message passing parallel implementation -- which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows. The information herein is subject to change without notice. Copyright c 2002-2016 Sandia Corporation. All rights reserved. Acknowledgements The BSIM Group at the University of California, Berkeley developed the BSIM3, BSIM4, BSIM6, BSIM-CMG and BSIM-SOI models. The BSIM3 is Copyright c 1999, Regents of the University of California. The BSIM4 is Copyright c 2006, Regents of the University of California. The BSIM6 is Copyright c 2015, Regents of the University of California. The BSIM-CMG is Copyright c 2012 and 2016, Regents of the University of California. The BSIM-SOI is Copyright c 1990, Regents of the University of California. All rights reserved. The Mextram model has been developed by NXP Semiconductors until 2007, Delft University of Technology from 2007 to 2014, and Auburn University since April 2015. Copyrights c of Mextram are with Delft University of Technology, NXP Semiconductors and Auburn University. The MIT VS Model Research Group developed the MIT Virtual Source (MVS) model. Copyright c 2013 Massachusetts Institute of Technology (MIT). The EKV3 MOSFET model was developed by the EKV Team of the Electronics Laboratory-TUC of the Technical University of Crete. Trademarks Xyce TM Electronic Simulator and Xyce TM are trademarks of Sandia Corporation. Orcad, Orcad Capture, PSpice and Probe are registered trademarks of Cadence Design Systems, Inc. Microsoft, Windows and Windows 7 are registered trademarks of Microsoft Corporation. Medici, DaVinci and Taurus are registered trademarks of Synopsys Corporation. Amtec and TecPlot are trademarks of Amtec Engineering, Inc. All other trademarks are property of their respective owners. Contacts World Wide Web http://xyce.sandia.gov https://info.sandia.gov/xyce (Sandia only) Email xyce@sandia.gov (outside Sandia) xyce-sandia@sandia.gov (Sandia only) Bug Reports (Sandia only) http://joseki-vm.sandia.gov/bugzilla http://morannon.sandia.gov/bugzilla
The objective of this memo is to present a brief report of the progress achieved during FY2016 on the investigation of ductile failure in the 2013 Sandia Fracture Challenge specimen. The experimental investigation was conducted with both the original steel A286 material used in the fracture challenge as well as with Al 7075-T651. The new results include further microscopy work for the steel A286 specimens, failure criterion verification for both materials and the implementation of a finite element model containing `material imperfections' to simulate the limit load in the response of the steel A286 specimens. Funding used to conduct the work presented here was provided by the ASC V&V program on validation of shear failure (Benjamin Reedlunn, PI) and from Sandia's LDRD program.
We applied modeling and simulation to examine the real-world tradeoffs between developingcountry public-health improvement and the need to improve the identification, tracking, and security of agents with bio-weapons potential. Traditionally, the international community has applied facility-focused strategies for improving biosecurity and biosafety. This work examines how system-level assessments and improvements can foster biosecurity and biosafety. We modeled medical laboratory resources and capabilities to identify scenarios where biosurveillance goals are transparently aligned with public health needs, and resource are distributed in a way that maximizes their ability to serve patients while minimizing security a nd safety risks. Our modeling platform simulates key processes involved in healthcare system operation, such as sample collection, transport, and analysis at medical laboratories. The research reported here extends the prior art by provided two key compone nts for comparative performance assessment: a model of patient interaction dynamics, and the capability to perform uncertainty quantification. In addition, we have outlined a process for incorporating quantitative biosecurity and biosafety risk measures. Two test problems were used to exercise these research products examine (a) Systemic effects of technological innovation and (b) Right -sizing of laboratory networks.
In the California Industrial General Permit (IGP) 2014-0057-DWQ for storm water monitoring, effective July 1, 2015, there are 21 contaminants that have been assigned NAL (Numeric Action Level) values, both annual and instantaneous. For annual NALs, an exceedance occurs when the average of all analytical results from all samples taken at a facility during a reporting year for a given parameter exceeds an annual NAL value listed in Table 2 of the General Permit. For instantaneous maximum NALs, an exceedance occurs when two or more analytical results from samples taken for any parameter within a reporting year exceed the instantaneous maximum NAL value (for TSS and O&G), or are outside of the instantaneous maximum NAL range (for pH) listed in Table 2. Table 2 is attached here for your review.
Whole cell biosensors (WCBs) utilize an organism’s natural ability to sense and respond to the environment. Through implementation of two different protein engineering methods, I seek to develop a WCB for the detection of important chemical signatures in the environment. I will reengineer the ligand binding profile of proteins known to alter transcription of genes, and I will engineer signal transduction in proteins already known to bind relevant compounds. In both cases, detection of compounds of interest will lead to the production of a measurable fluorescent signal within the organism. These approaches will provide the groundwork for the development of novel chemical sensing technologies that provide a cheap and efficient alternative to traditional methods for detection of compounds.
The Anomalous Environment Recorder (AE Recorder) provides a robust data recording capability for multiple high-shock applications including earth penetrators. The AE Recorder, packaged as a 2.4" di ameter cylinder 3" tall, acquires 12 accelerometer, 2 auxiliary, and 6 discrete signal channels at 250k samples / second. Recording depth is 213 seconds plus 75ms of pre-trigger data. The mechanical, electrical, and firmware are described as well as support electro nics designed for the first use of the recorder.
Our team has developed a new approach to entangling neutral atoms with a Rydberg-dressed interaction. Entangling neutral atoms is an essential key of quantum technologies such as quantum computation, many-body quantum simulation, and high-precision atomic sensors . The demonstrated Rydberg-dressed protocol involves adiabatically imposing a light shift on the ground state by coupling an excited Rydberg state with a tuned laser field. Using this technique, we have demonstrated a strong and tunable dipole - dipole interaction between two individually trapped atoms with energy shifts of order 1 MHz, which has been challenging to achieve in other protocols . During this program, we experimentally demonstrated Bell-state entanglement and the isomorphism to the Jaynes - Cumming model of a Rydberg-dressed two-atom system. Our theoretical calculations of a CPHASE quantum logic gate and arbitrary Dicke state quantum control in this system encourage further work.