Optical and x-ray characterization of the Daedalus ultrafast x-ray imager

Review of Scientific Instruments

Looker, Quinn M.; Kimmel, Mark W.; Yang, Chi; Porter, John L.

The Daedalus ultrafast x-ray imager is the latest generation in Sandia’s hybrid CMOS detector family. With three frames along an identical line of sight, 1 ns minimum integration time, a higher full well than Icarus, and added features, Daedalus brings exciting new capabilities to diagnostic applications in inertial confinement fusion and high energy density science. In this work, we present measurements of time response, dynamic range, spatial uniformity, pixel cross-talk, and absolute x-ray sensitivity using pulsed optical and x-ray sources. We report a measured 1.5 Me− full well, pixel sensitivity at 9.58 × 10−7 V/e−, and an estimate of spatial uniformity at ∼5% across the sensor array.

More Details

Demonstration of improved laser preheat with a cryogenically cooled magnetized liner inertial fusion platform

Review of Scientific Instruments

Harvey-Thompson, Adam J.; Geissel, Matthias G.; Crabtree, Jerry A.; Weis, Matthew R.; Gomez, Matthew R.; Fein, Jeffrey R.; Laros, James H.; Ampleford, David A.; Awe, Thomas J.; Chandler, Gordon A.; Hansen, Stephanie B.; Jennings, Christopher A.; Knapp, Patrick K.; Kimmel, Mark W.; Mangan, Michael M.; Peterson, Kyle J.; Porter, John L.; Rochau, G.A.; Ruiz, Daniel E.; Hanson, Joseph C.; Harding, Eric H.; Perea, L.; Robertson, Grafton K.; Shores, Jonathon S.; Slutz, Stephen A.; Smith, G.E.; Speas, Christopher S.; Yager-Elorriaga, David A.; York, Adam Y.

We report on progress implementing and testing cryogenically cooled platforms for Magnetized Liner Inertial Fusion (MagLIF) experiments. Two cryogenically cooled experimental platforms were developed: an integrated platform fielded on the Z pulsed power generator that combines magnetization, laser preheat, and pulsed-power-driven fuel compression and a laser-only platform in a separate chamber that enables measurements of the laser preheat energy using shadowgraphy measurements. The laser-only experiments suggest that ∼89% ± 10% of the incident energy is coupled to the fuel in cooled targets across the energy range tested, significantly higher than previous warm experiments that achieved at most 67% coupling and in line with simulation predictions. The laser preheat configuration was applied to a cryogenically cooled integrated experiment that used a novel cryostat configuration that cooled the MagLIF liner from both ends. The integrated experiment, z3576, coupled 2.32 ± 0.25 kJ preheat energy to the fuel, the highest to-date, demonstrated excellent temperature control and nominal current delivery, and produced one of the highest pressure stagnations as determined by a Bayesian analysis of the data.

More Details

Helium as a Surrogate for Deuterium in LPI Studies

Laser and Particle Beams

Geissel, Matthias G.; Harvey-Thompson, Adam J.; Weis, Matthew R.; Fein, Jeffrey R.; Bliss, David E.; Kimmel, Mark W.; Shores, Jonathon S.; Smith, Ian C.; Jennings, Christopher A.; Porter, John L.; Rambo, Patrick K.; Ampleford, David A.; Hansen, Aaron

Helium or neopentane can be used as surrogate gas fill for deuterium (D2) or deuterium-tritium (DT) in laser-plasma interaction studies. Surrogates are convenient to avoid flammability hazards or the integration of cryogenics in an experiment. To test the degree of equivalency between deuterium and helium, experiments were conducted in the Pecos target chamber at Sandia National Laboratories. Observables such as laser propagation and signatures of laser-plasma instabilities (LPI) were recorded for multiple laser and target configurations. It was found that some observables can differ significantly despite the apparent similarity of the gases with respect to molecular charge and weight. While a qualitative behaviour of the interaction may very well be studied by finding a suitable compromise of laser absorption, electron density, and LPI cross sections, a quantitative investigation of expected values for deuterium fills at high laser intensities is not likely to succeed with surrogate gases.

More Details

Maximization of Laser Coupling with Cryogenic Targets

Geissel, Matthias G.; Hansen, Aaron; Harvey-Thompson, Adam J.; Weis, Matthew R.; Crabtree, Jerry A.; Ampleford, David A.; Beckwith, Kristian B.; Fein, Jeffrey R.; Gomez, Matthew R.; Hanson, Joseph C.; Jennings, Christopher A.; Kimmel, Mark W.; Maurer, A.; Rambo, Patrick K.; Shores, Jonathon S.; Smith, Ian C.; Speas, Robert J.; Speas, Christopher S.; Porter, John L.

Abstract not provided.

A study of sacrificial mirrors for use prior to a laser wakefield accelerator driven by the Z-Petawatt laser

Galloway, Benjamin R.; Rambo, Patrick K.; Geissel, Matthias G.; Kimmel, Mark W.; Kellogg, Jeffrey W.; Elle, Jennifer; Garrett, Travis; Porter, John L.; Rochau, G.A.

Many experiments at Sandia’s Z Pulsed Power Facility require x-ray backlighting diagnostics to understand experiment performance. Due to limitations in present-day source/detection modalities, most x-ray diagnostics at Z are restricted to photon energies <20 keV, ultimately limiting the density, amount, and atomic number of targets diagnosable in experiments. These limitations force the use of low-Z materials like Beryllium, and they prevent acquisition of important backlighting data for materials/densities that are opaque to soft x-rays and where background emission from the Z load and transmission lines overwhelm diagnostics. In this LDRD project, we have investigated the design and development of a laser wakefield acceleration platform driven by the Z-Petawatt laser – a platform that would enable the generation of a pulsed, collimated beam of high energy x-rays up to 100 keV. Geometrical considerations for implementation on the Z Machine require the use of sacrificial mirrors, which have been tested in offline experiments in the Chama target chamber in building 983. Our results suggest the use of sacrificial mirrors would not necessarily inhibit the laser wakefield x-ray process, particularly with the benefits stemming from planned laser upgrades. These conclusions support the continuation of laser wakefield source research and the development of the necessary infrastructure to deliver the Z-Petawatt laser to the Z center section along the appropriate lines of sight. Ultimately, this new capability will provide unprecedented views through dense states of matter, enabling the use of previously incompatible target materials/designs, and uncovering a new set of observables accessible through diffraction and spectroscopy in the hard x-ray regime. These will amplify the data return on precious Z shots and enhance Sandia’s ability to investigate fundamental physics in support of national security.

More Details

Z-Petawatt Laser Highlights for FY21

Rambo, Patrick K.; Galloway, B.R.; Geissel, Matthias G.; Kimmel, Mark W.; Porter, John L.

We’re happy to report that the full-aperture upgrade project, started in FY18, is now complete and short-pulse target experiments are underway. The table below lists the present performance level of ZPW. Additional laser improvements are in progress to increase the laser energy and pulse contrast along with implementing a correction for achromatic aberrations to reduce the focused spot size and pulse width.

More Details

Magnetic field effects on laser energy deposition and filamentation in magneto-inertial fusion relevant plasmas

Physics of Plasmas

Lewis, S.M.; Weis, Matthew R.; Speas, Christopher S.; Kimmel, Mark W.; Bengtson, R.D.; Breizman, B.; Geissel, Matthias G.; Gomez, Matthew R.; Harvey-Thompson, Adam J.; Kellogg, Jeffrey W.; Long, Joel L.; Quevedo, H.J.; Rambo, Patrick K.; Riley, N.R.; Schwarz, Jens S.; Shores, Jonathon S.; Stahoviak, J.; Ampleford, David A.; Porter, John L.; Ditmire, T.; Looker, Quinn M.; Struve, Kenneth W.

We report on experimental measurements of how an externally imposed magnetic field affects plasma heating by kJ-class, nanosecond laser pulses. The experiments reported here took place in gas cells analogous to magnetized liner inertial fusion targets. We observed significant changes in laser propagation and energy deposition scale lengths when a 12T external magnetic field was imposed in the gas cell. We find evidence that the axial magnetic field reduces radial electron thermal transport, narrows the width of the heated plasma, and increases the axial plasma length. Reduced thermal conductivity increases radial thermal gradients. This enhances radial hydrodynamic expansion and subsequent thermal self-focusing. Our experiments and supporting 3D simulations in helium demonstrate that magnetization leads to higher thermal gradients, higher peak temperatures, more rapid blast wave development, and beam focusing with an applied field of 12T.

More Details

Investigating the energy balance in MagLIF preheat experiments

Harvey-Thompson, Adam J.; Geissel, Matthias G.; Crabtree, Jerry A.; Ampleford, David A.; Awe, Thomas J.; Beckwith, Kristian B.; Fein, Jeffrey R.; Gomez, Matthew R.; Hanson, Joseph C.; Jennings, Christopher A.; Kimmel, Mark W.; Maurer, A.; Shores, Jonathon S.; Smith, Ian C.; Speas, Robert J.; Speas, Christopher S.; York, Adam Y.; Porter, John L.; Paguio, Reny; Smith, Gary

Abstract not provided.

Lasergate: a windowless gas target for enhanced laser preheat in MagLIF

Galloway, B.R.; Slutz, Stephen A.; Kimmel, Mark W.; Rambo, Patrick K.; Schwarz, Jens S.; Geissel, Matthias G.; Harvey-Thompson, Adam J.; Weis, Matthew R.; Jennings, Christopher A.; Field, Ella S.; Kletecka, Damon E.; Looker, Quinn M.; Colombo, Anthony P.; Edens, Aaron E.; Smith, Ian C.; Shores, Jonathon S.; Speas, Christopher S.; Speas, Robert J.; Spann, Andrew; Sin, Justin; Gautier, Sophie; Sauget, Vincent; Treadwell, Paul; Rochau, G.A.; Porter, John L.

Abstract not provided.

Lasergate: A windowless gas target for enhanced laser preheat in magnetized liner inertial fusion

Physics of Plasmas

Galloway, B.R.; Slutz, Stephen A.; Kimmel, Mark W.; Rambo, Patrick K.; Schwarz, Jens S.; Geissel, Matthias G.; Harvey-Thompson, Adam J.; Weis, Matthew R.; Jennings, Christopher A.; Field, Ella S.; Kletecka, Damon E.; Looker, Quinn M.; Colombo, Anthony P.; Edens, Aaron E.; Smith, Ian C.; Shores, Jonathon S.; Speas, Christopher S.; Speas, Robert J.; Spann, A.P.; Sin, J.; Gautier, S.; Sauget, V.; Treadwell, P.A.; Rochau, G.A.; Porter, John L.

At the Z Facility at Sandia National Laboratories, the magnetized liner inertial fusion (MagLIF) program aims to study the inertial confinement fusion in deuterium-filled gas cells by implementing a three-step process on the fuel: premagnetization, laser preheat, and Z-pinch compression. In the laser preheat stage, the Z-Beamlet laser focuses through a thin polyimide window to enter the gas cell and heat the fusion fuel. However, it is known that the presence of the few μm thick window reduces the amount of laser energy that enters the gas and causes window material to mix into the fuel. These effects are detrimental to achieving fusion; therefore, a windowless target is desired. The Lasergate concept is designed to accomplish this by "cutting"the window and allowing the interior gas pressure to push the window material out of the beam path just before the heating laser arrives. In this work, we present the proof-of-principle experiments to evaluate a laser-cutting approach to Lasergate and explore the subsequent window and gas dynamics. Further, an experimental comparison of gas preheat with and without Lasergate gives clear indications of an energy deposition advantage using the Lasergate concept, as well as other observed and hypothesized benefits. While Lasergate was conceived with MagLIF in mind, the method is applicable to any laser or diagnostic application requiring direct line of sight to the interior of gas cell targets.

More Details

Increased preheat energy to MagLIF targets with cryogenic cooling

Harvey-Thompson, Adam J.; Geissel, Matthias G.; Crabtree, Jerry A.; Weis, Matthew R.; Gomez, Matthew R.; Fein, Jeffrey R.; Ampleford, David A.; Awe, Thomas J.; Chandler, Gordon A.; Galloway, B.R.; Hansen, Stephanie B.; Hanson, Jeffrey J.; Harding, Eric H.; Jennings, Christopher A.; Kimmel, Mark W.; Knapp, Patrick K.; Lamppa, Derek C.; Laros, James H.; Mangan, Michael M.; Maurer, A.; Perea, L.; Peterson, Kara J.; Porter, John L.; Rambo, Patrick K.; Robertson, Grafton K.; Rochau, G.A.; Ruiz, Daniel E.; Shores, Jonathon S.; Slutz, Stephen A.; Smith, Ian C.; Speas, Christopher S.; Yager-Elorriaga, David A.; York, Adam Y.; Paguio, R.R.; Smith, G.E.

Abstract not provided.

Evaluation of a fiber-coupled x-ray diffraction detector for dynamic compression experiments

Ao, Tommy A.; Smith, Anthony S.; Geissel, Matthias G.; Kimmel, Mark W.; Gard, Paul D.; Schollmeier, Marius

The long-term x-ray diffraction (XRD) detector scheme compatible with Z-containment experiments will involve conversion of the diffracted x-rays to optical light, which will be transported away from the Z-Dynamic Materials Properties (DMP) load and detected on a fast-gated camera. In this so-called DIffraction SCintillator Optic (DISCO) scheme , the scintillator is coupled to a long, coherent imaging fiber bundle using a custom lens system with high numerical aperture. In addition, the DISCO diagnostic incorporates time-gating to allow measurement only during the short time window of the x-ray pulse in which XRD occurs, thereby significantly reducing unwanted background generated by the Z-DMP load. Dynamic compression experiments were performed at the Chama target chamber to evaluate the DISCO diagnostic . Specifically, a Zr sample was laser-shocked with the Chaco laser while the Z-Beamlet (ZBL) laser was used to generate x-rays, which enabled time-gated 6.7-keV XRD patterns from the compressed Zr sample to be obtained.

More Details

Update on MagLIF preheat experiments

Harvey-Thompson, Adam J.; Geissel, Matthias G.; Weis, Matthew R.; Galloway, B.R.; Fein, Jeffrey R.; Awe, Thomas J.; Crabtree, Jerry A.; Ampleford, David A.; Bliss, David E.; Glinsky, Michael E.; Gomez, Matthew R.; Hanson, Joseph C.; Harding, Eric H.; Jennings, Christopher A.; Kimmel, Mark W.; Perea, L.; Peterson, Kyle J.; Porter, James D.; Rambo, Patrick K.; Robertson, Grafton K.; Ruiz, Daniel E.; Schwarz, Jens S.; Shores, Jonathon S.; Slutz, Stephen A.; Smith, Ian C.; York, Adam Y.; Paguio, R.R.; Smith, G.E.; Maudlin, M.; Pollock, B.

Abstract not provided.

X-ray characterization of the Icarus ultrafast x-ray imager

Review of Scientific Instruments

Looker, Quinn M.; Colombo, Anthony P.; Kimmel, Mark W.; Porter, John L.

Ultrafast x-ray imagers developed at Sandia National Laboratories are a transformative diagnostic tool in inertial confinement fusion and high energy density physics experiments. The nanosecond time scales on which these devices operate are a regime with little precedent, and applicable characterization procedures are still developing. This paper presents pulsed x-ray characterization of the Icarus imager under a variety of illumination levels and timing modes. Results are presented for linearity of response, absolute sensitivity, variation of response with gate width, and image quality.

More Details
Results 1–25 of 134