A colinear Second-Harmonic Orthogonal Polarized (SHOP) interferometer diagnostic capable of making electron areal density measurements of plasmas formed in Magnetically Insulated Transmission Lines (MITLs) has been developed.
In magnetized liner inertial fusion (MagLIF), a cylindrical liner filled with fusion fuel is imploded with the goal of producing a one-dimensional plasma column at thermonuclear conditions. However, structures attributed to three-dimensional effects are observed in self-emission x-ray images. Despite this, the impact of many experimental inputs on the column morphology has not been characterized. We demonstrate the use of a linear regression analysis to explore correlations between morphology and a wide variety of experimental inputs across 57 MagLIF experiments. Results indicate the possibility of several unexplored effects. For example, we demonstrate that increasing the initial magnetic field correlates with improved stability. Although intuitively expected, this has never been quantitatively assessed in integrated MagLIF experiments. We also demonstrate that azimuthal drive asymmetries resulting from the geometry of the “current return can” appear to measurably impact the morphology. In conjunction with several counterintuitive null results, we expect the observed correlations will encourage further experimental, theoretical, and simulation-based studies. Finally, we note that the method used in this work is general and may be applied to explore not only correlations between input conditions and morphology but also with other experimentally measured quantities.
Auto-magnetizing (AutoMag) liners are cylindrical tubes that employ helical current flow to produce strong internal axial magnetic fields prior to radial implosion on ~100 ns timescales. AutoMag liners have demonstrated strong uncompressed axial magnetic field production (>100 T) and remarkable implosion uniformity during experiments on the 20 MA Z accelerator. However, both axial field production and implosion morphology require further optimization to support the use of AutoMag targets in magnetized liner inertial fusion (MagLIF) experiments. Data from experiments studying the initiation and evolution of dielectric flashover in AutoMag targets on the Mykonos accelerator have enabled the advancement of magnetohydrodynamic (MHD) modeling protocols used to simulate AutoMag liner implosions. Implementing these protocols using ALEGRA has improved the comparison of simulations to radiographic data. Specifically, both the liner in-flight aspect ratio and the observed width of the encapsulant-filled helical gaps during implosion in ALEGRA simulations agree more closely with radiography data compared to previous GORGON simulations. Although simulations fail to precisely reproduce the measured internal axial magnetic field production, improved agreement with radiography data inspired the evaluation of potential design improvements with newly developed modeling protocols. Three-dimensional MHD simulation studies focused on improving AutoMag target designs, specifically seeking to optimize the axial magnetic field production and enhance the cylindrical implosion uniformity for MagLIF. Importantly, by eliminating the driver current prepulse and reducing the initial inter-helix gap widths in AutoMag liners, simulations indicate that the optimal 30–50 T range of precompressed axial magnetic field for MagLIF on Z can be accomplished concurrently with improved cylindrical implosion uniformity.
Experimental measurements of low density plasmas forming in Magnetically Insulated Transmission Line (MITL) regions are desired to improve our understanding of current loss and power flow. Therefore, a new optical interferometer diagnostic was commissioned via this LDRD project. To measure the expected 1013 - 1017 cm-3 electron densities inside the 0.5 - 6 mm Anode-Cathode (A-K) gaps, a colinear SHOP interferometer diagnostic was constructed. The diagnostic was initially fielded on the University of New Mexico (UNM) Helicon-Cathode (HelCat) plasma device which provided a highly repeatable and well understood plasma source for which the colinear SHOP interferometer’s functionality could be verified and measured. Utilizing the highly repeatable plasma source and shot averaging, the interferometer was able to achieve an areal density sensitivity of 1×1014 cm-2. This work at UNM lead to a Review of Scientific Instruments (RSI) publication [20], DOI:10.1063/5.0101687. After the diagnostic’s capability was proven at UNM, the colinear SHOP interferometer was commissioned for use on the Sandia National Laboratories (SNL) Mykonos accelerator. Here, it provided the first temporal areal density measurements of plasma formation in a parallel plate MITL. The diagnostic was able to achieve a single shot (no multi-shot averaging like at UNM) areal density sensitivity of 1×1015 cm-2 along a ~ 2mm probing path length, which provided adequate capability to conduct fundamental physics research of MITL plasma formation. CHICAGO and ALEGRA simulations support the diagnostics experimental findings. More experimental and computational work will continue, likely leading to another publication(s). The smaller scale Mykonos accelerator work has also provided justification that the colinear SHOP interferometer is a capable diagnostic for measuring plasma areal densities in the inner MITL and convolute regions of larger TW-class accelerators like SNL’s Z machine.
Electrothermal instability plays an important role in applications of current-driven metal, creating striations (which seed the magneto-Rayleigh-Taylor instability) and filaments (which provide a more rapid path to plasma formation). However, the initial formation of both structures is not well understood. Simulations show for the first time how a commonly occurring isolated defect transforms into the larger striation and filament, through a feedback loop connecting current and electrical conductivity. Simulations have been experimentally validated using defect-driven self-emission patterns.
Using three-dimensional (3D) magnetohydrodynamic simulations, we study how a pit on a metal surface evolves when driven by intense electrical current density j. Redistribution of j around the pit initiates a feedback loop: j both reacts to and alters the electrical conductivity σ, through Joule heating and hydrodynamic expansion, so that j and σ are constantly in flux. Thus, the pit transforms into larger striation and filament structures predicted by the electrothermal instability theory. Both structures are important in applications of current-driven metal: Here, the striation constitutes a density perturbation that can seed the magneto-Rayleigh-Taylor instability, while the filament provides a more rapid path to plasma formation, through 3D j redistribution. Simulations predict distinctive self-emission patterns, thus allowing for experimental observation and comparison.
We report on progress implementing and testing cryogenically cooled platforms for Magnetized Liner Inertial Fusion (MagLIF) experiments. Two cryogenically cooled experimental platforms were developed: an integrated platform fielded on the Z pulsed power generator that combines magnetization, laser preheat, and pulsed-power-driven fuel compression and a laser-only platform in a separate chamber that enables measurements of the laser preheat energy using shadowgraphy measurements. The laser-only experiments suggest that ∼89% ± 10% of the incident energy is coupled to the fuel in cooled targets across the energy range tested, significantly higher than previous warm experiments that achieved at most 67% coupling and in line with simulation predictions. The laser preheat configuration was applied to a cryogenically cooled integrated experiment that used a novel cryostat configuration that cooled the MagLIF liner from both ends. The integrated experiment, z3576, coupled 2.32 ± 0.25 kJ preheat energy to the fuel, the highest to-date, demonstrated excellent temperature control and nominal current delivery, and produced one of the highest pressure stagnations as determined by a Bayesian analysis of the data.
Plasma formation from intensely ohmically heated conductors is known to be highly non-uniform, as local overheating can be driven by micron-scale imperfections. Detailed understanding of plasma formation is required to predict the performance of magnetically driven physics targets and magnetically-insulated transmission lines (MITLs). Previous LDRD-supported work (projects 178661 and 200269) developed the electrothermal instability (ETI) platform, on the Mykonos facility, to gather high-resolution images of the self-emission from the non-uniform ohmic heating of z-pinch rods. Experiments studying highly inhomogeneous alloyed aluminum captured complex heating topography. To enable detailed comparison with magnetohydrodynamic (MHD) simulation, 99.999% pure aluminum rods in a z-pinch configuration were diamond-turned to ~10nm surface roughness and then further machined to include well-characterized micron-scale "engineered" defects (ED) on the rod's surface (T.J. Awe, et al., Phys. Plasmas 28, 072104 (2021)). In this project, the engineered defect hardware and diagnostic platform were used to study ETI evolution and non-uniform plasma formation from stainless steel targets. The experimental objective was to clearly determine what, if any, role manufacturing, preparation, or alloy differences have in encouraging nonuniform heating and plasma formation from high-current density stainless steel. Data may identify improvements that may be implemented in the fabrication/preparation of electrodes used on the Z machine. Preliminary data shows that difference in manufacturer has no observed effect on ETI evolution, stainless alloy 304L heated more uniformly than alloy 310 at similar current densities, and that stainless steel undergoes the same evolutionary ETI stages as ultra-pure aluminum, with increased emission tied to areas of elevated surface roughness.
Here we present a new analysis methodology that allows for the self-consistent integration of multiple diagnostics including nuclear measurements, x-ray imaging, and x-ray power detectors to determine the primary stagnation parameters, such as temperature, pressure, stagnation volume, and mix fraction in magnetized liner inertial fusion (MagLIF) experiments. The analysis uses a simplified model of the stagnation plasma in conjunction with a Bayesian inference framework to determine the most probable configuration that describes the experimental observations while simultaneously revealing the principal uncertainties in the analysis. We validate the approach by using a range of tests including analytic and three-dimensional MHD models. An ensemble of MagLIF experiments is analyzed, and the generalized Lawson criterion χ is estimated for all experiments.
Auto-magnetizing (AutoMag) liners are cylindrical tubes composed of discrete metallic helices encapsulated in insulating material; when driven with a ∼2 MA, ∼100-ns prepulse on the 20 MA, 100-ns rise time Z accelerator, AutoMag targets produced >150 T internal axial magnetic fields [Shipley et al., Phys. Plasmas 26, 052705 (2019)]. Once the current rise rate of the pulsed power driver reaches sufficient magnitude, the induced electric fields in the liner cause dielectric breakdown of the insulator material and, with sufficient current, the cylindrical target radially implodes. The dielectric breakdown process of the insulating material in AutoMag liners has been studied in experiments on the 500-900 kA, ∼100-ns rise time Mykonos accelerator. Multi-frame gated imaging enabled the first time-resolved observations of photoemission from dynamically evolving plasma distributions during the breakdown process in AutoMag targets. Using magnetohydrodynamic simulations, we calculate the induced electric field distribution and provide a detailed comparison to the experimental data. We find that breakdown in AutoMag targets does not primarily depend on the induced electric field in the gaps between conductive helices as previously thought. Finally, to better control the dielectric breakdown time, a 12-32 mJ, 170 ps ultraviolet (λ = 266 nm) laser was implemented to irradiate the outer surface of AutoMag targets to promote breakdown in a controlled manner at a lower internal axial field. The laser had an observable effect on the time of breakdown and subsequent plasma evolution, indicating that pulsed UV lasers can be used to control breakdown timing in AutoMag.
We present an overview of the magneto-inertial fusion (MIF) concept MagLIF (Magnetized Liner Inertial Fusion) pursued at Sandia National Laboratories and review some of the most prominent results since the initial experiments in 2013. In MagLIF, a centimeter-scale beryllium tube or "liner" is filled with a fusion fuel, axially pre-magnetized, laser pre-heated, and finally imploded using up to 20 MA from the Z machine. All of these elements are necessary to generate a thermonuclear plasma: laser preheating raises the initial temperature of the fuel, the electrical current implodes the liner and quasi-adiabatically compresses the fuel via the Lorentz force, and the axial magnetic field limits thermal conduction from the hot plasma to the cold liner walls during the implosion. MagLIF is the first MIF concept to demonstrate fusion relevant temperatures, significant fusion production (>10^13 primary DD neutron yield), and magnetic trapping of charged fusion particles. On a 60 MA next-generation pulsed-power machine, two-dimensional simulations suggest that MagLIF has the potential to generate multi-MJ yields with significant self-heating, a long-term goal of the US Stockpile Stewardship Program. At currents exceeding 65 MA, the high gains required for fusion energy could be achievable.
Magnetized Liner Inertial Fusion (MagLIF) [Slutz et al., Phys. Plasmas 17, 056303 (2010)] experiments driven by the Z machine produce >1013 deuterium-deuterium fusion reactions [Gomez et al., Phys. Rev. Lett. 125, 155002 (2020)]. Simulations indicate high yields and gains (1000) with increased current and deuterium-tritium layers for burn propagation [Slutz et al., Phys. Plasmas 23, 022702 (2016)]. Such a coating also isolates the metal liner from the gaseous fuel, which should reduce mixing of liner material into the fuel. However, the vapor density at the triple point is only 0.3 kg/m3, which is not high enough for MagLIF operation. We present two solutions to this problem. First, a fuel wetted low-density plastic foam can be used to form a layer on the inside of the liner. The desired vapor density can be obtained by controlling the temperature. This does however introduce carbon into the layer which will enhance radiation losses. Simulations indicate that this wetted foam layer can significantly contribute to the fusion yield when the foam density is less than 35 kg/m3. Second, we show that a pure frozen fuel layer can first be formed on the inside of the liner and then low temperature gaseous fuel can be introduced just before the implosion without melting a significant amount of the ice layer. This approach is the most promising for MagLIF to produce high yield and gain.
We present experimental results from the first systematic study of performance scaling with drive parameters for a magnetoinertial fusion concept. In magnetized liner inertial fusion experiments, the burn-averaged ion temperature doubles to 3.1 keV and the primary deuterium-deuterium neutron yield increases by more than an order of magnitude to 1.1×1013 (2 kJ deuterium-tritium equivalent) through a simultaneous increase in the applied magnetic field (from 10.4 to 15.9 T), laser preheat energy (from 0.46 to 1.2 kJ), and current coupling (from 16 to 20 MA). Individual parametric scans of the initial magnetic field and laser preheat energy show the expected trends, demonstrating the importance of magnetic insulation and the impact of the Nernst effect for this concept. A drive-current scan shows that present experiments operate close to the point where implosion stability is a limiting factor in performance, demonstrating the need to raise fuel pressure as drive current is increased. Simulations that capture these experimental trends indicate that another order of magnitude increase in yield on the Z facility is possible with additional increases of input parameters.
Using the analogy between hydrodynamic and electrical current flow, we study how electrical current density j redistributes and amplifies due to two commonly encountered inhomogeneities in metals. First, we consider flow around a spherical resistive inclusion and find significant j amplification, independent of inclusion size. Hence, even μm-scale inclusions can affect performance in applications by creating localized regions of enhanced Joule heating. Next, we investigate j redistribution due to surface roughness, idealized as a sinusoidal perturbation with amplitude A and wavelength λ. Theory predicts that j amplification is determined by the ratio A/λ, so that even "smooth"surface finishes (i.e., small A) can generate significant amplification, if λ is correspondingly small. We compare theory with magnetohydrodynamic simulation to illustrate both the utility and limitations of the steady-state theory.
The electrothermal instability (ETI) is driven by Joule heating and arises from the dependence of resistivity on temperature. ETI may drive azimuthally correlated surface density variations which seed magneto Rayleigh-Taylor (MRT) instability growth. Liner implosion studies suggest that dielectric surface coatings reduce the amplitude of ETI driven perturbations. Furthermore, previous fundamental physics studies suggest that non-metallic inclusions within the metal can seed ETI growth. In this project, we aimed to (1) determine how dielectric coatings modify ETI growth by varying the coating thickness and the surface structure of the underlying metal, and (2) study overheating from engineered defects—designed lattices of micron-scale pits. Engineered pits divert current density and drive local overheating in a way that can be compared with 3DMHD simulations. All experiments were executed on the Sandia Mykonos Facility. Facility and diagnostic investments enabled high quality data to be gathered in support of project deliverables.
In the first auto-magnetizing liner implosion experiments on the Z Facility, precompressed internal axial fields near 150 T were measured and 7.2-keV radiography indicated a high level of cylindrical uniformity of the imploding liner's inner surface. An auto-magnetizing (AutoMag) liner is made of discrete metallic helical conductors encapsulated in insulating material. Here, the liner generates internal axial magnetic field as a 1–2 MA, 100–200 ns current prepulse flows through the helical conductors. After the prepulse, the fast-rising main current pulse causes the insulating material between the metallic helices to break down ceasing axial field production. After breakdown, the helical liner, nonuniform in both density and electrical conductivity, implodes in 100 ns. In-flight radiography data demonstrate that while the inner wall maintains cylindrical uniformity, multiple new helically oriented structures are self-generated within the outer liner material layers during the implosion; this was not predicted by simulations. Furthermore, liner stagnation was delayed compared to simulation predictions. An analytical implosion model is compared with experimental data and preshot simulations to explore how changes in the premagnetization field strength and drive current affect the liner implosion trajectory. Both the measurement of >100 T internal axial field production and the demonstration of cylindrical uniformity of the imploding liner's inner wall are encouraging for promoting the use of AutoMag liners in future MagLIF experiments.