Low Thermal Budget PMOS in Low Temperature Epitaxial Silicon
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
On October 1, 2022, sound level measurements were taken at various locations throughout Kirtland Air Force Base (KAFB) and Southeastern Albuquerque. The purpose was to support sound propagation modeling predictions and sound regulations for public exposure during the detonation of an approximately 300-pound energetic experiment. Ground Zero was located on Range 7 of Sandia Thunder Range (06647). A total of 8 measurement locations were identified (e.g., 5 on KAFB and 3 in the Southeastern Albuquerque neighborhoods).
Elastomeric rubbers serve a vital role as sealing materials in the hydrogen storage and transport infrastructure. With applications including O-rings and hose-liners, these components are exposed to pressurized hydrogen at a range of temperatures, cycling rates, and pressure extremes. Cyclic (de)pressurization is known to degrade these materials through the process of cavitation. This readily visible failure mode occurs as a fracture or rupture of the material and is due to the oversaturated gas localizing to form gas bubbles. Computational modeling in the Hydrogen Materials Compatibility Program (H-Mat), co-led by Sandia National Laboratories and Pacific Northwest National Laboratory, employs multi-scale simulation efforts to build a predictive understanding of hydrogen-induced damage in materials. Modeling efforts within the project aim to provide insight into how to formulate materials that are less sensitive to high-pressure hydrogen-induced failure. In this document, we summarize results from atomistic molecular dynamics simulations, which make predictive assessments of the effects of compositional variations in the commonly used elastomer, ethylene propylene diene monomer (EPDM).
Abstract not provided.
Abstract not provided.
Abstract not provided.
Microgrids require reliable communication systems for equipment control, power delivery optimization, and operational visibility. To maintain secure communications, Microgrid Operational Technology (OT) networks must be defensible and cyber-resilient. The communication network must be carefully architected with appropriate cyber-hardening technologies to provide security defenders the data, analytics, and response capabilities to quickly mitigate malicious and accidental cyberattacks. In this work, we outline several best practices and technologies that can support microgrid operations (e.g., intrusion detection and monitoring systems, response tools, etc.). Then we apply these recommendations to the New Jersey TRANSITGRID use case to demonstrate how they would be deployed in practice.
Abstract not provided.
Renewable Energy
Photovoltaic (PV) performance is affected by reversible and irreversible losses. These can typically be mitigated through responsive and proactive operations and maintenance (O&M) activities. However, to generate profit, the cost of O&M must be lower than the value of the recovered electricity. This value depends both on the amount of recovered energy and on the electricity prices, which can vary significantly over time in spot markets. The present work investigates the impact of the electricity price variability on the PV profitability and on the related O&M activities in Italy, Portugal, and Spain. It is found that the PV revenues varied by 1.6 × to 1.8 × within the investigated countries in the last 5 years. Moreover, forecasts predict higher average prices in the current decade compared to the previous one. These will increase the future PV revenues by up to 60% by 2030 compared to their 2015–2020 mean values. These higher revenues will make more funds available for better maintenance and for higher quality components, potentially leading to even higher energy yield and profits. Linearly growing or constant price assumptions cannot fully reproduce these expected price trends. Furthermore, significant price fluctuations can lead to unexpected scenarios and alter the predictions.
Grid operating security studies are typically employed to establish operating boundaries, ensuring secure and stable operation for a range of operation under NERC guidelines. However, if these boundaries are severely violated, existing system security margins will be largely unknown, as would be a secure incremental dispatch path to higher security margins while continuing to serve load. As an alternative to the use of complex optimizations over dynamic conditions, this work employs the use of machine learning to identify a sequence of secure state transitions which place the grid in a higher degree of operating security with greater static and dynamic stability margins. Several reinforcement learning solution methods were developed using deep learning neural networks, including Deep Q-learning, Mu-Zero, and the continuous algorithms Proximal Reinforcement Learning, and Advantage Actor Critic Learning. The work is demonstrated on a power grid with three control dimensions but can be scaled in size and dimensionality, which is the subject of ongoing research.
A collection of x-ray computed tomography scans of candy.
Abstract not provided.
Abstract not provided.
Abstract not provided.
This manual describes the use of the Xyce™ Parallel Electronic Simulator. Xyce™ has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: (1) Capability to solve extremely large circuit problems by supporting large-scale parallel computing platforms (up to thousands of processors). This includes support for most popular parallel and serial computers. (2) A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one to develop new types of analysis without requiring the implementation of analysis-specific device models. (3) Device models that are specifically tailored to meet Sandia's needs, including some radiation-aware devices (for Sandia users only). (4) Object-oriented code design and implementation using modern coding practices. Xyce™ is a parallel code in the most general sense of the phrase—a message passing parallel implementation—which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel eficiency is achieved as the number of processors grows.
This manual describes the installation and use of the Xyce™ XDM Netlist Translator. XDM simplifies the translation of netlists generated by commercial circuit simulator tools into Xyce-compatible netlists. XDM currently supports translation from PSpice, HSPICE, and Spectre netlists into Xyce™ netlists.
One detonation test was monitored for impulse noise at Thunder Range on November 6, 2020. The TNT equivalency for this shot was 100 lbs. Ground zero for this test was located at an open area of Range 7. The Armag, where MOW were remotely located, was just south of the east end of the TR shock tube The purpose of this sampling event was to characterize the noise attenuation provided by the Armag which will be used as the primary firing location in a future test series. To determine attenuation provided by the Armag, one sound level monitor was placed inside and a second monitor was placed outside the hardened structure at the same distance from ground zero. The Armag was located 1300 feet from ground zero. Essential personnel performing these tests were remotely located inside the Armag and wore hearing protection with a minimum NRR of 23. Members of the Workforce (MOW) who are exposed to noise levels above 140 dBC, regardless of hearing protection worn, are required to be enrolled into the SNL Hearing Conservation Program which includes audiometric testing, online training (HCP100) and wearing hearing protection.
Abstract not provided.
Abstract not provided.