Coupling MOS Quantum Dot and Phosphorous Donor Qubit Systems
Abstract not provided.
Abstract not provided.
Neutron sensing is critical in civilian, military, industrial, biological, medical, basic research, and environmental applications. Conventional neutron sensors are limited by size, weight, cost, portability, and helium supply. Here the microfabrication of Gd conversion material-based heterojunction diodes is described for detecting thermal neutrons using electrical signals produced by internal conversion electrons (ICE). Films with negligible stress were produced at the tensile-compressive crossover point, enabling Gd coatings of any desired thickness by controlling the radiofrequency sputtering power and using the zero-point near p(Ar) of 50 mTorr at 100 W. Post-deposition Gd oxidation-induced spallation was eliminated by growing a residual stress-free 50 nm neodymium-doped aluminum cap layer atop Gd. Resultant coatings were stable for at least six years demonstrating excellent product shelf life. Depositing Gd on the diode surface eliminated air gap, leading to improved efficiency and facilitating monolithic microfabrication. The conversion electron spectrum was dominated by ICE with energies of 72, 132, and 174 keV. Results are reported on neutron reflection and moderation by polyethylene for enhanced sensitivity and γ- and X-ray elimination for improved specificity. Optimal Gd thickness was 10.4 μm with 300 μm thick partially depleted diode of 300 mm2 active surface area. Fast detection within 10 minutes at a neutron source-to-diode distance of 11.7 cm was achieved using this configuration. All ICE energies along with γ-ray and Kα X-ray were modeled to emphasize correlations between experiment and theory and to calculate efficiencies. Semiconductor thermal neutron detectors offer advantages for field-sensing of radioactive neutron sources.
Abstract not provided.
Abstract not provided.
Review of Scientific Instruments
We report on the development of a highly miniaturized vacuum package for use in an atomic clock utilizing trapped ytterbium-171 ions. The vacuum package is approximately 1 cm3 in size and contains a linear quadrupole RF Paul ion trap, miniature neutral Yb sources, and a non-evaporable getter pump. We describe the fabrication process for making the Yb sources and assembling the vacuum package. To prepare the vacuum package for ion trapping, it was evacuated, baked at a high temperature, and then back filled with a helium buffer gas. Once appropriate vacuum conditions were achieved in the package, it was sealed with a copper pinch-off and was subsequently pumped only by the non-evaporable getter. We demonstrated ion trapping in this vacuum package and the operation of an atomic clock, stabilizing a local oscillator to the 12.6 GHz hyperfine transition of 171Y b+. The fractional frequency stability of the clock was measured to be 2 × 10-11/τ1/2.
Abstract not provided.
Abstract not provided.
There is a need in many fields, such as nuclear medicine, non-proliferation, energy exploration, national security, homeland security, nuclear energy, etc, for miniature, thermal neutron detectors. Until recently, thermal neutron detection has required physically large devices to provide sufficient neutron interaction and transduction signal. Miniaturization would allow broader use in the fields just mentioned and open up other applications potentially. Recent research shows promise in creating smaller neutron detectors through the combination of high-neutron-cross-section converter materials and solid-state devices. Yet, till recently it is difficult to measure low neutron fluxes by solidstate means given the need for optimized converter materials (purity, chemical composition and thickness) and a lack of designs capable of efficient transduction of the neutron conversion products (x-rays, electrons, gamma rays). Gadolinium-based semiconductor heterojunctions have detected electrons produced by Gd-neutron reactions but only at high neutron fluxes. One of the main limitations to this type of approach is the use of thin converter layers and the inability to utilize all the conversion products. In this LDRD we have optimized the converter material thickness and chemical composition to improve capture of conversion electrons and have detected thermal neutrons with high fidelity at low flux. We are also examining different semiconductor materials and converter materials to attempt to capture a greater percentage of the conversion electrons, both low and higher energy varieties. We have studied detector size and bias scaling, and cross-sensitivity to xrays and shown that we can detect low fluxes of thermal neutrons in less than 30 minutes with high selectivity by our approach. We are currently studying improvements in performance with direct placement of the Gd converter on the detector. The advancement of sensitive, miniature neutron detectors will have benefits in energy production, nonproliferation and medicine.
Sandia journal manuscript; Not yet accepted for publication
Deterministic control over the location and number of donors is crucial to donor spin quantum bits (qubits) in semiconductor based quantum computing. A focused ion beam is used to implant close to quantum dots. Ion detectors are integrated next to the quantum dots to sense the implants. The numbers of ions implanted can be counted to a precision of a single ion. Regular coulomb blockade is observed from the quantum dots. Charge offsets indicative of donor ionization, are observed in devices with counted implants.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
This report describes initial testing of the NG Sensor GTX-1000 natural gas monitoring system. This testing showed that the retention time, peak area stability and heating value repeatability of the GTX-1000 were promising for natural gas measurements in the field or at the well head. The repeatability can be less than 0.25% for LHV and HHV for the Airgas standard tested in this report, which is very promising for a first generation prototype. Ultimately this system should be capable of 0.1% repeatability in heating value at significant size and power reductions compared with competing systems.
Abstract not provided.
Abstract not provided.
Macromolecular Rapid Communications
The synthesis of two new polyphenylene vinylene (PPV) precursor polymers which can be thermally induced to eliminate pentanol is presented. Pentanol has recently been discovered to be a very useful lubricant in MicroElectroMechanical Systems. The utilization of the elimination reaction of precursor polymers to PPV as a small molecule delivery platform has, to the best of our knowledge, not been previously reported. The elimination reactions were examined using thermal gravimetric analysis, gas chromatography, and UV-Vis spectroscopy. Using PPV precursors allows for (1) a high loading of lubricant (one molecule per monomeric unit), (2) a platform that requires relatively high temperatures (>145 °C) to eliminate the lubricant, and (3) a non-volatile, mechanically and chemically stable by-product of the elimination reaction (PPV). The "on-demand" delivery of a vapor-phase lubricant to MicroElectoMechanical Systems (MEMS) will allow for scheduled or as-needed lubrication of the moving components, improving the performance, reliability, and lifespan of the devices. A delivery system utilizing a newly designed microhotplate along with two new precursor poly(p-phenylene vinylene) polymers that thermally eliminate a pentanol lubricant is described. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Abstract not provided.
This report will detail the process by which the silicon carbide (SiC) microhotplate devices, manufactured by GE, were imaged using IR microscopy equipment available at Sandia. The images taken were used as inputs to a finite element modeling (FEM) process using the ANSYS software package. The primary goal of this effort was to determine a method to measure the temperature of the microhotplate. Prior attempts to monitor the device's temperature by measuring its resistance had proven to be unreliable due to the nonlinearity of the doped SiC's resistance with temperature. As a result of this thermal modeling and IR imaging, a number of design recommendations were made to facilitate this temperature measurement. The lower heating value (LHV) of gaseous fuels can be measured with a catalyst-coated microhotplate calorimeter. GE created a silicon carbide (SiC) based microhotplate to address high-temperature survivability requirements for the application. The primary goal of this effort was to determine a method to measure the temperature of the microhotplate. Prior attempts to monitor the device's temperature by measuring its resistance had proven to be unreliable due to the non-linearity of the doped SiC's resistance with temperature. In this work, thermal modeling and IR imaging were utilized to determine the operation temperature as a function of parameters such as operation voltage and device sheet resistance. A number of design recommendations were made according to this work.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
2007 IEEE Conference on Technologies for Homeland Security: Enhancing Critical Infrastructure Dependability
Accurate, periodic calibration is required to operate IMS, GC, and portal security systems with maximum efficiency, surety, and operator confidence. To this end, we are presently developing a microfabricated device for on-demand calibration of fleldable contraband detection instruments. Using robotically-assisted picoliter dispensing methods, precise nanogram or larger amounts of calibration compound(s) are placed on micron-sized bridge structures. Resistively heating these structures delivers precisely quantified low-levels of calibration compounds to the detector systems. This provides reliable calibration for identification and quantification of explosives, narcotics, and other contraband. © 2007 IEEE.
Abstract not provided.
Sandia journal manuscript; Not yet accepted for publication
Here, self-assembled monolayers (SAMS) have been investigated for their ability to confine the absorption of the motor protein kinesin and direct the movement of microtubule shuttles (MTs) within channels of a lithographically patterned microfluidic device. Channels were made from gold films deposited on a silicon wafer to provide chemically distinct surfaces for the selective formation of a range of alkane thiol monolayers on channel walls. Devices were then exposed to solutions containing casein and kinesin to develop protein monolayers capable of propelling microtubules in the presence of adenosine triphosphate (ATP) fuel. Fluorescence microscopy images were used to observe the attachment of MTs to chemically distinct regions and to evaluate the ability of the various monolayer coatings to confine the movement of MTs within the channel system. Ellipsometry was used to characterize the protein adsorption characteristics of SAMS terminated with different functional groups to help establish confinement mechanisms. Finally, both anti-fouling and cationic monolayers were found to be effective in confining MT movement within the channels by controlling the adsorption or orientation of the casein buffer layers that mediate motor protein attachment and functionality.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
A microflame-based detector suit has been developed for sensing of a broad range of chemical analytes. This detector combines calorimetry, flame ionization detection (FID), nitrogen-phosphorous detection (NPD) and flame photometric detection (FPD) modes into one convenient platform based on a microcombustor. The microcombustor consists in a micromachined microhotplate with a catalyst or low-work function material added to its surface. For the NPD mode a low work function material selectively ionizes chemical analytes; for all other modes a supported catalyst such as platinum/alumina is used. The microcombustor design permits rapid, efficient heating of the deposited film at low power. To perform calorimetric detection of analytes, the change in power required to maintain the resistive microhotplate heater at a constant temperature is measured. For FID and NPD modes, electrodes are placed around the microcombustor flame zone and an electrometer circuit measures the production of ions. For FPD, the flame zone is optically interrogated to search for light emission indicative of deexcitation of flame-produced analyte compounds. The calorimetric and FID modes respond generally to all hydrocarbons, while sulfur compounds only alarm in the calorimetric mode, providing speciation. The NPD mode provides 10,000:1 selectivity of nitrogen and phosphorous compounds over hydrocarbons. The FPD can distinguish between sulfur and phosphorous compounds. Importantly all detection modes can be established on one convenient microcombustor platform, in fact the calorimetric, FID and FPD modes can be achieved simultaneously on only one microcombustor. Therefore, it is possible to make a very universal chemical detector array with as little as two microcombustor elements. A demonstration of the performance of the microcombustor in each of the detection modes is provided herein.
The natural gas industry seeks inexpensive sensors and instrumentation to rapidly measure gas heating value in widely distributed locations. For gas pipelines, this will improve gas quality during transfer and blending, and will expedite accurate financial accounting. Industrial endusers will benefit through continuous feedback of physical gas properties to improve combustion efficiency during use. To meet this need, Sandia has developed a natural gas heating value monitoring instrument using existing and modified microfabricated components. The instrument consists of a silicon micro-fabricated gas chromatography column in conjunction with a catalytic micro-calorimeter sensor. A reference thermal conductivity sensor provides diagnostics and surety. This combination allows for continuous calorimetric determination with a 1 minute analysis time and 1.5 minute cycle time using air as a carrier gas. This system will find application at remote natural gas mining stations, pipeline switching and metering stations, turbine generators, and other industrial user sites. Microfabrication techniques will allow the analytical components to be manufactured in production quantities at a low per-unit cost.
Abstract not provided.
Proposed for publication in Sensors and Actuators B.
This work describes the design, computational prototyping, fabrication, and characterization of a microfabricated thermal conductivity detector ({mu}TCD) to analyze the effluent from a micro-gas chromatograph column ({mu}GC) and to complement the detection efficacy of a surface acoustic wave detector in the micro-ChemLab{trademark} system. To maximize the detection sensitivity, we designed a four-filament Wheatstone bridge circuit where the resistors are suspended by a thin silicon nitride membrane in pyramidal or trapezoidal shaped flow cells. The geometry optimization was carried out by simulation of the heat transfer in the devices, utilizing a boundary element algorithm. Within microfabrication constraints, we determined and fabricated nine sensitivity-optimized geometries of the {mu}TCD. The nine optimal geometries were tested with two different flow patterns. We demonstrated that the perpendicular flow, where the gas directly impinged upon the membrane, yielded a sensitivity that is three times greater than the parallel flow, where the gas passed over the membrane. The functionality of the {mu}TCD was validated with the theoretical prediction and showed a consistent linear response to effluent concentrations, with a detection sensitivity of 1 ppm, utilizing less than 1 W of power.