Magneto-optical measurement of magnetic field and electrical current on a short pulse high energy pulsed power accelerator

AIP Advances

Owens, Israel O.; Coffey, Sean K.; Ulmen, Benjamin A.; Harrison, Richard K.; Trujillo, Alex; Rhoades, Elaine L.; Mccutcheon, Brandon; Grabowski, Theodore C.

We describe a direct magneto-optical approach to measuring the magnetic field driven by a narrow pulse width (<10 ns), 20 kA electrical current flow in the transmission line of a high energy pulsed power accelerator. The magnetic field and electrical current are among the most important operating parameters in a pulsed power accelerator and are critical to understanding the properties of the radiation output. However, accurately measuring these fields and electrical currents using conventional pulsed power diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element sensing crystal sensor that is highly resistant to electromagnetic interference and does not require external calibration. Here, we focus on device theory, operating parameters, results from an experiment on a high energy pulsed power accelerator, and comparison to a conventional electrical current shunt sensor.

More Details

Time- and Energy-Resolved Coupled Saturn Radiation Environments Simulations Using the Integrated Tiger Series (ITS) Code

Depriest, Kendall D.; Pointon, Timothy D.; Sirajuddin, David S.; Ulmen, Benjamin A.

Using a newly developed coupling of the ElectroMagnetic Plasma In Realistic Environments (EMPIRE) code with the Integrated Tiger Series (ITS) code, radiation environment calculations have been performed. The effort was completed as part of the Saturn Recapitalization (Recap) program that represents activities to upgrade and modernize the Saturn accelerator facility. The radiation environment calculations performed provide baseline results with current or planned hardware in the facility. As facility design changes are proposed and implemented as part of Saturn Recap, calculations of the radiation environment will be performed to understand how the changes impact the output of the Saturn accelerator.

More Details

Measuring Saturn's Electron Beam Energy Spectrum using Webb's Wedges

Ulmen, Benjamin A.; Webb, Timothy J.; McCourt, Andrew L.; Coffey, Sean K.

It is very difficult to measure the voltage of the load on the Saturn accelerator. Time-resolved measurements such as vacuum voltmeters and V-dot monitors are impractical at best and completely change the pulsed power behavior at the load at worst. We would like to know the load voltage of the machine so that we could correctly model the radiation transport and tune our x-ray unfold methodology and circuit simulations of the accelerator. Step wedges have been used for decades as a tool to measure the end - point energies of high energy particle beams. Typically, the technique is used for multi-megavolt accelerators, but we have adapted it to Saturn's modest <2 MV end-point energy and modified the standard bremsstrahlung x-ray source to extract the electron beam without changing the physics of the load region. We found clear evidence of high energy electrons >2 MV. We also attempted to unfold an electron energy spectrum using a machine learning algorithm and while these results come with large uncertainties, they qualitatively agree with PIC simulation results.

More Details

An X-ray Intensity Operations Monitor (AXIOM) (Final LDRD Project Report)

Ulmen, Benjamin A.; Webb, Timothy J.; Radtke, Gregg A.; Olson, Aaron J.; Depriest, Kendall D.; Coffey, Sean K.; Looker, Quinn M.; Gao, Xujiao G.; Nicholas, Ryder N.; Edwards, Jarrod D.; McCourt, Andrew L.; Bell, Kate S.

The Saturn accelerator has historically lacked the capability to measure time-resolved spectra for its 3-ring bremsstrahlung x-ray source. This project aimed to create a spectrometer called AXIOM to provide this capability. The project had three major development pillars: hardware, simulation, and unfold code. The hardware consists of a ring of 24 detectors around an existing x-ray pinhole camera. The diagnostic was fielded on two shots at Saturn and over 100 shots at the TriMeV accelerator at Idaho Accelerator Center. A new Saturn x-ray environment simulation was created using measured data to validate. This simulation allows for timeresolved spectra computation to compare the experimental results. The AXIOM-Unfold code is a new parametric unfold code using modern global optimizers and uncertainty quantification. The code was written in Python, uses Gitlab version control and issue tracking, and has been developed with long term code support and maintenance in mind.

More Details

Saturn Radiation Dose Environment Characterization

Ulmen, Benjamin A.; Depriest, Kendall D.; Olson, Aaron J.; Webb, Timothy J.; Edwards, Jarrod D.

To understand the environment where a time-resolved hard x-ray spectrometer (AXIOM) might be fielded, experiments and simulations were performed to analyze the radiation dose environment underneath the Saturn vacuum dome. Knowledge of this environment is critical to the design and placement of the spectrometer. Experiments demonstrated that the machine performance, at least in terms of on-axis dose, has not significantly changed over the decades. Simulations of the off-axis dose were performed to identify possible spectrometer locations of interest. The effects from the source and dome hardware as well as source distributions and angles of incidence on the radiation environment were also investigated. Finally, a unified radiation transport model was developed for two widely used radiation transport codes to investigate the off-axis dose profiles and the time-dependent x-ray energy spectrum. The demonstrated equivalence of the unified radiation transport model between the radiation transport codes allows the team to tie future time-dependent x-ray environment calculations to previous integral simulations for the Saturn facility.

More Details

Simulation and Modeling of Time-Resolved X-Ray Detector for the Saturn Accelerator

IEEE Transactions on Nuclear Science

Gao, Xujiao G.; Looker, Quinn M.; Webb, Timothy J.; Depriest, Kendall D.; Ulmen, Benjamin A.

We present the technology-aided computer design (TCAD) device simulation and modeling of a silicon p-i-n diode for detecting time-dependent X-ray radiation. We show that the simulated forward and reverse breakdown current-voltage characteristics agree well with the measured data under nonradiation environment by only calibrating carrier lifetimes for the forward bias case and avalanche model critical fields for the reverse bias condition. Using the calibrated parameters and other nominal material properties, we simulated the radiation responses of the p-i-n diode and compared with experimental data when the diode was exposed to X-ray radiation at Sandia's Saturn facility and the Idaho State University (ISU) TriMeV facility. For Saturn's Gaussian dose-rate pulses, we show three findings from TCAD simulations. First, the simulated photocurrents are in excellent agreement with the measured data for two dose-rate pulses with peak values of 1.16 times 10 -{10} and 1.88 times 10 -{10} rad(Si)/s. Second, the simulation results of high dose-rate pulses predict increased delayed photocurrents with longer time tails in the diode electrical responses due to excess carrier generation. Third, simulated peak values of diode radiation responses versus peak dose rates at different bias conditions provide useful guidance to determine the dose-rate range that the p-i-n diode can reliably detect in experiment. For TriMeV's non-Gaussian dose-rate pulse, our simulated diode response is in decent agreement with the measured data without further calibration. We also studied the effects of device geometry, recombination process, and dose-rate enhancement via TCAD simulations to understand the higher measured response in the time after the peak dose-rate radiation for the p-i-n diode exposed to TriMeV irradiation.

More Details

Three-Dimensional Model of the Saturn Accelerator Water Tri-Plate Transmission Line Connection to the Vacuum Insulator Stack

IEEE International Pulsed Power Conference

Struve, Kenneth W.; Ulmen, Benjamin A.

Calculation of the power flow from the 36 pulse forming lines to the vacuum region of Saturn has always been complicated by the three-dimensional structure of the rod and bottle connections to the vacuum insulator stack. Recently we have completed a 3-D calculation of the bottle configuration and found a large error in previous impedance estimates. We have used this calculation to determine impedance and to construct a 2-D model of each of the 36 bottles of each level of the insulator using the Transmission Line Matrix (TLM) technique. These TLM models are then used in a 2-D model for each of the three levels of the insulator. Each model starts at a measured forward-going pulse in the water tri-plate and ends at the Brehmstrahlung load at the center of the machine. Because of long transmission line lengths and short pulse lengths, each level can be considered independent of the others. A combination of the three models then represents a quasi-3-D model of the load region of the machine. The results of these calculations agree well with measurement and thereby provide confidence in simulation predictions for those areas where measurements are not possible. Details of the 3-D bottle calculation, the TLM model, and results of the load region simulations using this model are given.

More Details

Electro-Optical Measurement of Electric Fields for Pulsed Power Systems

IEEE International Pulsed Power Conference

Owens, Israel O.; Grabowski, Theodore C.; Joseph, N.; Coffey, Sean K.; Ulmen, Benjamin A.; Kirschner, Debra S.; Rainwater, Kirk R.; Struve, Kenneth W.

The electric field strength between the cathode and anode (i.e., the voltage) of a pulsed power machine is one of the most important operating parameters of the device. However, to date, accurate and precise voltage measurements on these high energy pulsed power systems have proved difficult if not virtually impossible to perform. In many cases, the measurements to be performed take place in an environment cluttered with electromagnetic interference (EMI), radio frequency interference (RFI), and electron pollution, and there is the potential for electrical discharge (or arcing), there is limited physical access, or the measurement area is deemed unsuitable due to radiation safety concerns. We report on an electro-optical-based approach to measuring strong, narrow-pulse-width electric fields that requires no interfering metallic probes or components to disturb the field to be measured. Here we focus on device theory, operating parameters and a laboratory experiment.