Publications

Results 751–775 of 99,299

Search results

Jump to search filters

Coupled hydro-thermal flow and radionuclide transport driven by spatial variation of heat-generating radioactive wastes in shale formations

Tunnelling and Underground Space Technology

Chang, Kyung W.; Laforce, Tara C.

Deep geologic disposal of multiple nuclear waste packages with various heat sources can induce nonuniform hydro-thermal behaviors in the near-field of the repository, consequently influencing the long-term radionuclide transport in the far-field once waste form breach initiates. This study looks into three cases with variation in the spatial order of six groups of heat sources (10th, 50th, 75th, 90th, 95th, and 99th percentiles of heat outputs generated from 1,981 as-loaded dual-purpose canisters in the field site) in a shale-hosted repository with respect to the uni-directional groundwater flow (from west to east): (1) cooler waste packages from west to east, (2) hotter waste packages from west to east, and (3) hottest waste packages in the middle of the repository. Our field-scale PFLOTRAN simulation represents heat-driven multiphysics coupled mechanisms, including multiphase flow, heat transfer, and chemical/radioactive transport, and also, calculates the onset of waste form breach based on temperature-dependent canister vitality. The results from this sensitivity study will quantify the short- (less than 1 × 103 years) and long-term (up to 1 × 106 years) impacts of sporadic heat pulses from waste package on the spatio-temporal perturbation in hydro-thermal flow quantities and the rate of radionuclide transport in both near- and far-field of the repository system.

More Details

Modeling Tungsten Boride Neutronics in ORIGEN for Z-Facility

Arguello, Christian A.

ORIGEN is one of the main transmutation software packages used in nuclear engineering Modeling Tungsten Boride Neutronics in ORIGEN for Z-Facilityproblems. For the case of this study, tungsten borides are studied using a coupled framework between MCNP and the ORIGEN package of scale. The input used four compositions of tungsten boride: WB with natural boron- 10 abundance, WB with 80wt% B-10 per isotope of boron, WB4 with natural boron-10 abundance, and WB4 with 80wt% B-10 per isotope of boron. Isotopic inventories were produced for WB which show the time dependent change up to 2 years after a 6-Month irradiation. This will allow for further studies of the materials to assess things material composition changes, dose contribution, and waste management requirements.

More Details

Low-Frequency Noise and Deep Level Transient Spectroscopy in n-p-n Si Bipolar Junction Transistors Irradiated with Si Ions

IEEE Transactions on Nuclear Science

Luo, Xuyi; Montes, Jossue; Koukourinkova, Sabina D.; Vaandrager, Bastiaan L.; Bielejec, Edward S.; Vizkelethy, Gyorgy; Schrimpf, Ronald D.; Fleetwood, Daniel M.; Zhang, En X.

The properties of defects in n-p-n Si bipolar junction transistors (BJTs) caused by 17-MeV Si ions are investigated via current-voltage, low-frequency (LF) noise, and deep level transient spectroscopy (DLTS) measurements. Four prominent radiation-induced defects in the base-collector junction of these transistors are identified via DLTS. At least two defect levels are observed in temperature-dependent LF 1/f noise measurements, one that is similar to a prominent defect in DLTS and another that is not. Defect microstructures are discussed. Our results show that DLTS and 1/f noise measurements can provide complementary information about defects in linear bipolar devices.

More Details

A comparison of the neutron detection efficiency and response characteristics of two pixelated PSD-capable organic scintillator detectors with different photo-detection readout methods

Journal of Instrumentation

Marleau, P.; Sweany, Melinda D.; Balajthy, Jon A.

We characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved performance over the previously developed PMT-based detector both in terms of uniformity and neutron detection efficiency. Each detector array uses PSD-capable plastic scintillator as a detection medium. We describe the calibration and neutron efficiency measurement of both detectors using a 137Cs source for energy calibration and a 252Cf source for calibration of the neutron response. We find that the intrinsic neutron detection efficiency of the SiPM-based array is (30.2 ± 0.9)%, which is almost twice that of the PMT-based array, which we measure to be (16.9 ± 0.1)%.

More Details

Seeing in with X-rays: 4D Strain and Thermometry Measurements for Thermal-Mechanical Testing

Winters, C.; Jones, E.M.C.; Halls, Benjamin R.; Murray, Shannon E.; Miers, John C.; Westphal, Eric R.; Hansen, Linda E.; Lowry, Daniel R.; Fayad, S.S.; Obenauf, Dayna G.; Vogel, Dayton J.; Quintana, Enrico C.; Davis, Seth M.; Ramirez, Abraham J.; Jauregui, Luis; Roper, Christopher M.

Understanding temperature-dependent material decomposition and structural deformation induced by combined thermal-mechanical environments is critical for safety qualification of hardware under accident scenarios. Seeing in with X-rays elucidated the physics necessary to develop X-ray strain and thermometry diagnostics for use in optically opaque environments. Two parallel thermometry schemes were explored: X-ray fluorescence and X-ray diffraction of inorganic doped ceramics– colloquially known as thermographic phosphors. Two parallel surface strain techniques–Path-Integrated Digital Image Correlation and Frequency Multiplexed Digital Image Correlation–were demonstrated. Finally, preliminary demonstration of time-resolved digital volume correlation was performed by taking advantage of limited view reconstruction techniques. Additionally, research into blended ceramic-metal coatings was critical to generating intrinsic thermographic patterns for the future combination of X-ray strain and thermometry measurements.

More Details
Results 751–775 of 99,299
Results 751–775 of 99,299