The effects of surface roughness on specular diagnostics in shocked experiments

Review of Scientific Instruments

Grant, Sean C.; Ao, T.

Many shock experiments, whether impact, laser, or magnetically driven, use reflected optical light from shocked samples to diagnose their material properties. Specifically, optical velocimetry diagnostics, which do not require absolute power measurements, are regularly used to obtain equation-of-state information of materials. However, new diagnostics will be necessary to expand the realm of measured material properties, and many useful diagnostic techniques do require absolute measurements. Thus, it is important to understand what happens at the reflective surface of shock experiments, and the effect scattering has on the light collection of optical probes. To this end, we present results from experiments done to observe the behavior of a reflected beam from a specular coating on an optical window during shock impact. We find that the specular condition of the coating is adversely affected by the shock front, but this can be mitigated by minimizing roughness on the surface preceding the coating.

More Details

X-ray diffraction of dynamically compressed matter on Sandia's Z Pulsed Power Facility

Ao, T.; Schollmeier, Marius; Bays, Nathan R.; Gard, Paul D.; Williams, James R.; Blada, Caroline B.; Hanshaw, Heath L.; Smith, Ian C.; Shores, Jonathon; Speas, Christopher S.; Seagle, Cristopher T.

Sandia's Z Pulsed Power Facility is able to dynamically compress matter to extreme states with exceptional uniformity, duration, and size, which are ideal for investigations of fundamental material properties of high energy density conditions. X-ray diffraction (XRD) is a key atomic scale probe since it provides direct observation of the compression and strain of the crystal lattice, and is used to detect, identify, and quantify phase transitions. Because of the destructive nature of Z-Dynamic Materials Properties (DMP) experiments and low signal vs background emission levels of XRD, it is very challenging to detect the XRD pattern close to the Z-DMP load and to recover the data. We developed a new Spherical Crystal Diffraction Imager (SCDI) diagnostic to relay and image the diffracted x-ray pattern away from the load debris field. The SCDI diagnostic utilizes the Z-Beamlet laser to generate 6.2-keV Mn-He c , x-rays to probe a shock-compressed sample on the Z-DMP load. A spherically bent crystal composed of highly oriented pyrolytic graphite is used to collect and focus the diffracted x-rays into a 1-inch thick tungsten housing, where an image plate is used to record the data. We performed experiments to implement the SCDI diagnostic on Z to measure the XRD pattern of shock compressed beryllium samples at pressures of 1.8-2.2 Mbar.

More Details

Polycapillary x-ray lenses for single-shot, laser-driven powder diffraction

Review of Scientific Instruments

Schollmeier, Marius; Ao, T.; Field, Ella; Galloway, Benjamin R.; Bays, Nathan R.; Kimmel, Mark; Morgan, D.V.; Rambo, Patrick K.; Schwarz, Jens; Shores, Jonathon; Smith, Ian C.; Speas, Christopher S.; Bays, Nathan R.; Porter, John L.

X-ray diffraction measurements to characterize phase transitions of dynamically compressed high-Z matter at Mbar pressures require both sufficient photon energy and fluence to create data with high fidelity in a single shot. Large-scale laser systems can be used to generate x-ray sources above 10 keV utilizing line radiation of mid-Z elements. However, the laser-to-x-ray energy conversion efficiency at these energies is low, and thermal x-rays or hot electrons result in unwanted background. We employ polycapillary x-ray lenses in powder x-ray diffraction measurements using solid target x-ray emission from either the Z-Beamlet long-pulse or the Z-Petawatt (ZPW) short-pulse laser systems at Sandia National Laboratories. Polycapillary lenses allow for a 100-fold fluence increase compared to a conventional pinhole aperture while simultaneously reducing the background significantly. This enables diffraction measurements up to 16 keV at the few-photon signal level as well as diffraction experiments with ZPW at full intensity.

More Details

X-Ray Diffraction Measurements on Laser-Compressed Polycrystalline Samples Using a Short-Pulse Laser Generated X-Ray Source

Schollmeier, Marius; Ao, T.; Field, Ella; Galloway, Benjamin R.; Bays, Nathan R.; Kimmel, Mark; Long, Joel; Morgan, Dane V.; Rambo, Patrick K.; Schwarz, Jens; Seagle, Cristopher T.

Existing models for most materials do not describe phase transformations and associated lattice dy- namics (kinetics) under extreme conditions of pressure and temperature. Dynamic x-ray diffraction (DXRD) allows material investigations in situ on an atomic scale due to the correlation between solid-state structures and their associated diffraction patterns. In this LDRD project we have devel- oped a nanosecond laser-compression and picosecond-to-nanosecond x-ray diffraction platform for dynamically-compressed material studies. A new target chamber in the Target Bay in building 983 was commissioned for the ns, kJ Z-Beamlet laser (ZBL) and the 0.1 ns, 250 J Z-Petawatt (ZPW) laser systems, which were used to create 8-16 keV plasma x-ray sources from thin metal foils. The 5 ns, 15 J Chaco laser system was converted to a high-energy laser shock driver to load material samples to GPa stresses. Since laser-to-x-ray energy conversion efficiency above 10 keV is low, we employed polycapillary x-ray lenses for a 100-fold fluence increase compared to a conventional pinhole aperture while simultaneously reducing the background significantly. Polycapillary lenses enabled diffraction measurements up to 16 keV with ZBL as well as diffraction experiments with ZPW. This x-ray diffraction platform supports experiments that are complementary to gas guns and the Z facility due to different strain rates. Ultimately, there is now a foundation to evaluate DXRD techniques and detectors in-house before transferring the technology to Z. This page intentionally left blank.

More Details

Superfast assembly and synthesis of gold nanostructures using nanosecond low-temperature compression via magnetic pulsed power

Nature Communications

Fan, Hongyou; Li, Binsong; Bian, Kaifu; Lane, James M.D.; Salerno, K.M.; Grest, Gary S.; Ao, T.; Hickman, Randy J.; Wise, Jack L.; Zhou, Xiaowang; Wang, Zhongwu

Gold nanostructured materials exhibit important size- and shape-dependent properties that enable a wide variety of applications in photocatalysis, nanoelectronics and phototherapy. Here we show the use of superfast dynamic compression to synthesize extended gold nanostructures, such as nanorods, nanowires and nanosheets, with nanosecond coalescence times. Using a pulsed power generator, we ramp compress spherical gold nanoparticle arrays to pressures of tens of GPa, demonstrating pressure-driven assembly beyond the quasi-static regime of the diamond anvil cell. Our dynamic magnetic ramp compression approach produces smooth, shockless (that is, isentropic) one-dimensional loading with low-temperature states suitable for nanostructure synthesis. Transmission electron microscopy clearly establishes that various gold architectures are formed through compressive mesoscale coalescences of spherical gold nanoparticles, which is further confirmed by in-situ synchrotron X-ray studies and large-scale simulation. This nanofabrication approach applies magnetically driven uniaxial ramp compression to mimic established embossing and imprinting processes, but at ultra-short (nanosecond) timescales.

More Details

Development of Dynamic Ellipsometry for Measurements or Iron Conductivity at Earth's Core Conditions

Grant, Sean C.; Ao, T.; Davis, Jean-Paul; Bays, Nathan R.; Seagle, Cristopher T.; Lin, Jung-Fu; Bernstein, Aaron

The CHEDS researchers are engaged in a collaborative research project to study the properties of iron and iron alloys under Earth’s core conditions. The Earth’s core, inner and outer, is composed primarily of iron, thus studying iron and iron alloys at high pressure and temperature conditions will give the best estimate of its properties. Also, comparing studies of iron alloys with known properties of the core can constrain the potential light element compositions found within the core, such as fitting sound speeds and densities of iron alloys to established inner- Earth models. One of the lesser established properties of the core is the thermal conductivity, where current estimates vary by a factor of three. Therefore, one of the primary goals of this collaboration is to make relevant measurements to elucidate this conductivity.

More Details
Results 51–75 of 153
Results 51–75 of 153
Top