Assessing parallel path cooling tower performance via artificial neural networks

Annals of Nuclear Energy

Katinas, Christopher M.; D'Entremont, Brian; Ray, William; Willis, Michael J.; Reichardt, Thomas A.

Real-time monitoring of a research nuclear reactor, a system in which all generated power is dissipated to the environment, can be performed via analysis of the heat rejection from the cooling system. Given an inlet water temperature and flow rate, the reactor power can be well-approximated from the outlet water temperature; however, the instrumentation to measure outlet conditions may not be robust or accurate. If we know how a cooling tower performs from historical data, but cannot measure the outlet temperature, a mathematical representation of the system can be inverted to obtain the outlet water temperature that describes the cooling capacity. Unfortunately, model inversion processes are computationally expensive. To address this, an artificial neural network (ANN) is implemented to assess the performance of a multi-cell cooling tower for a nuclear reactor. This approach leverages the Merkel model to obtain an extensive data set describing performance of the cooling tower cells throughout a wide array of potential operating conditions. The Merkel model is expressed as a function of four parameters: the inlet and outlet water temperatures, inlet air wet bulb temperature, and ratio of liquid-to-gas mass flow rates (L/G), which together provide a non-dimensional number indicative of cooling tower performance, called the Merkel integral. Computing a 4-dimensional data structure that describes finite combinations of the Merkel integral, an inverse model is then generated using an ANN to determine the cell outlet water temperature from the other three model parameters along with the computed Merkel integral. Compared to traditional model inversion methods, the ANN reduces the computational time by approximately 4 orders of magnitude, with effectively no sacrifice to solution accuracy, and could be applied for different cooling towers in the event the performance curve is known. Finally, three use cases of the ANN are then reviewed: (1) determining the cell outlet water temperatures when gas flow at rated conditions (GFRC) is known, (2) performing the prior case without knowledge of the GRFC, and (3) assessing performance differences between the individual tower cells.

More Details

Industrial PLC Network Modeling and Parameter Identification Using Sensitivity Analysis and Mean Field Variational Inference

Sensors

Ching, David C.; Safta, Cosmin S.; Reichardt, Thomas A.; Wonnacott, Raelynn; Rashkin, Lee; Chilleri, John

A multiple input multiple output (MIMO) power line communication (PLC) model for industrial facilities was developed that uses the physics of a bottom-up model but can be calibrated like top-down models. The PLC model considers 4-conductor cables (three-phase conductors and a ground conductor) and has several load types, including motor loads. The model is calibrated to data using mean field variational inference with a sensitivity analysis to reduce the parameter space. The results show that the inference method can accurately identify many of the model parameters, and the model is accurate even when the network is modified.

More Details

Calculation of Nuclear Reactor Cooling Tower Performance With Limited Data Streams

Journal of Thermal Science and Engineering Applications

Katinas, Christopher M.; Reichardt, Thomas A.; Kulp, Thomas J.; Entremont, William'; Ray, William; Willis, Michael

Abstract Monitoring of cooling tower performance in a nuclear reactor facility is necessary to ensure safe operation; however, instrumentation for measuring performance characteristics can be difficult to install and may malfunction or break down over long duration experiments. This paper describes employing a thermodynamic approach to quantify cooling tower performance, the Merkel model, which requires only five parameters, namely, inlet water temperature, outlet water temperature, liquid mass flowrate, gas mass flowrate, and wet bulb temperature. Using this model, a general method to determine cooling tower operation for a nuclear reactor was developed in situations when neither the outlet water temperature nor gas mass flowrate are available, the former being a critical piece of information to bound the Merkel integral. Furthermore, when multiple cooling tower cells are used in parallel (as would be in the case of large-scale cooling operations), only the average outlet temperature of the cooling system is used as feedback for fan speed control, increasing the difficulty of obtaining the outlet water temperature for each cell. To address these shortcomings, this paper describes a method to obtain individual cell outlet water temperatures for mechanical forced-air cooling towers via parametric analysis and optimization. In this method, the outlet water temperature for an individual cooling tower cell is acquired as a function of the liquid-to-gas ratio (L/G). Leveraging the tight tolerance on the average outlet water temperature, an error function is generated to describe the deviation of the parameterized L/G to the highly controlled average outlet temperature. The method was able to determine the gas flowrate at rated conditions to be within 3.9% from that obtained from the manufacturer’s specification, while the average error for the four individual cooling cell outlet water temperatures were 1.6 °C, −0.5 °C, −1.0 °C, and 0.3 °C.

More Details

An algorithmic approach to predicting mechanical draft cooling tower fan speeds from infrasound signals

Applied Acoustics

Eaton, Samuel W.; Cardenas, Edna S.; Hix, Jay D.; Johnson, James T.; Watson, Scott M.; Chichester, David L.; Garces, Milton A.; Magana-Zook, Steven A.; Maceira, Monica; Marcillo, Omar E.; Chai, Chengping; D'Entremont, Brian P.; Reichardt, Thomas A.

Mechanical draft cooling towers (MDCTs) serve a critical heat management role in a variety of industries. For nuclear reactors in particular, the consistent, predictable operation of MDCTs is required to avoid damage to infrastructure and reduce the potential for catastrophic failure. Accurate, reliable measurement of MDCT fan speed is therefore an important maintenance and safety requirement. To that end, we have developed an algorithm for automatically predicting the rotational speeds of multiple, simultaneously operating fan rotors using contactless, infrasound measurements. The algorithm is based on identifying the blade passing frequencies (BPFs), their harmonics, as well as the motor frequencies (MFs) for each fan in operation. Using the algorithm, these frequencies can be automatically identified in the acoustic waveform's short-time Fourier transform spectrogram. Attribution is aided by a set of filters that rely on the unique spectral and temporal characteristics of fan operation, as well as the intrinsic frequency ratios of the BPF harmonics and the BPF/MF signals. The algorithm was tested against infrasound data acquired from infrasound sensors deployed at two research reactors: the Advanced Test Reactor (ATR) located at Idaho National Laboratory (INL) and the High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory (ORNL). After manually identifying the MDCT gearbox ratio, the algorithm was able to quickly yield fan speeds at both reactors in good agreement with ground truth. Ultimately, this work demonstrates the ease by which MDCT fans may be monitored in order to optimize operational conditions and avoid infrastructure damage.

More Details

Hyperspectral Signature Analysis and Characterization in Support of Remote Detection of Chemical and Biological Exposures

Proceedings of SPIE - The International Society for Optical Engineering

Katinas, Christopher M.; Timlin, Jerilyn A.; Slater, Jonathon T.; Reichardt, Thomas A.

Remote assessment of physiological parameters has enabled patient diagnostics without the need for a medical professional to become exposed to potential communicable diseases. In particular, early detection of oxygen saturation, abnormal body temperature, heart rate, and/or blood pressure could affect treatment protocols. The modeling effort in this work uses an adding-doubling radiative transfer model of a seven-layer human skin structure to describe absorption and reflection of incident light within each layer. The model was validated using both abiotic and biotic systems to understand light interactions associated with surfaces consisting of complex topography as well as multiple illumination sources. Using literature-based property values for human skin thickness, absorption, and scattering, an average deviation of 7.7% between model prediction and experimental reflectivity was observed in the wavelength range of 500-1000 nm.

More Details

Sensitivity-informed bayesian inference for home plc network models with unknown parameters

Energies

Ching, David C.; Safta, Cosmin S.; Reichardt, Thomas A.

Bayesian inference is used to calibrate a bottom-up home PLC network model with unknown loads and wires at frequencies up to 30 MHz. A network topology with over 50 parameters is calibrated using global sensitivity analysis and transitional Markov Chain Monte Carlo (TMCMC). The sensitivity-informed Bayesian inference computes Sobol indices for each network parameter and applies TMCMC to calibrate the most sensitive parameters for a given network topology. A greedy random search with TMCMC is used to refine the discrete random variables of the network. This results in a model that can accurately compute the transfer function despite noisy training data and a high dimensional parameter space. The model is able to infer some parameters of the network used to produce the training data, and accurately computes the transfer function under extrapolative scenarios.

More Details

Spectroradiometric detection of competitor diatoms and the grazer Poteriochromonas in algal cultures

Algal Research

Reichardt, Thomas A.; Maes, Danae M.; Jensen, Travis J.; Dempster, Thomas A.; Mcgowen, John A.; Poorey, Kunal N.; Curtis, Deanna J.; Lane, Todd L.; Timlin, Jerilyn A.

To address challenges in early detection of pond pests, we have extended a spectroradiometric monitoring method, initially demonstrated for measurement of pigment optical activity and biomass, to the detection of algal competitors and grazers. The method relies upon measurement and interpretation of pond reflectance spectra spanning from the visible into the near-infrared. Reflectance spectra are acquired every 5 min with a multi-channel, fiber-coupled spectroradiometer, providing monitoring of algal pond conditions with high temporal frequency. The spectra are interpreted via numerical inversion of a reflectance model, in which the above-water reflectance is expressed in terms of the absorption and backscatter coefficients of the cultured species, with additional terms accounting for the pigment fluorescence features and for the water-surface reflection of sunlight and skylight. With this method we demonstrate detection of diatoms and the predator Poteriochromonas in outdoor cultures of Nannochloropsis oceanica and Chlorella vulgaris, respectively. The relative strength of these signatures is compared to microscopy and sequencing analysis. Spectroradiometric detection of diatoms is then further assessed on beaker-contained mixtures of Microchloropsis salina with Phaeodactylum tricornutum, Thalassiosira weissflogii, and Thalassiosira pseudonana, respectively, providing an initial evaluation of the sensitivity and specificity of detecting pond competitors.