Publications

Results 51–100 of 105

Search results

Jump to search filters

Soliton production with nonlinear homogeneous lines

IEEE Transactions on Plasma Science

Coleman, Phillip D.; Moorman, Matthew W.; Brown, Douglas G.; Petney, Sharon; Dudley, Evan C.; Youngman, Kevin Y.; Penner, Tim D.; Fang, Lu; Myers, Katherine M.; Elizondo-Decanini, Juan M.

Low- and high-voltage Soliton waves were produced and used to demonstrate collision and compression using diode-based nonlinear transmission lines. Experiments demonstrate soliton addition and compression using homogeneous nonlinear lines. We built the nonlinear lines using commercially available diodes. These diodes are chosen after their capacitance versus voltage dependence is used in a model and the line design characteristics are calculated and simulated. Nonlinear ceramic capacitors are then used to demonstrate high-voltage pulse amplification and compression. The line is designed such that a simple capacitor discharge, input signal, develops soliton trains in as few as 12 stages. We also demonstrated output voltages in excess of 40 kV using Y5V-based commercial capacitors. The results show some key features that determine efficient production of trains of solitons in the kilovolt range.

More Details

Investigations into the chemical structure based selectivity of the microfabricated nitrogen-phosphorus detector

Sensors and Actuators, B: Chemical

Brocato, Terisse A.; Hess, Ryan; Moorman, Matthew W.; Simonson, Robert J.

Nitrogen and phosphorus atoms are constituents of some of the most toxic chemical vapors. Nitrogen-phosphorus gas chromatograph detectors (NPDs) rely on selective ionization of such compounds using ionization temperatures typically greater than 600°C. NPDs have previously been reported to be 7 × 104× and 105× more sensitive for nitrogen and phosphorus, respectively, than for carbon. Presented here is an investigation of the structure-based selectivity of a microfabricated nitrogen-phosphorus detector (μNPD). The μNPD presented here is smaller than a dime and can be placed in a system that is 1/100th the size of a commercial NPD. Comparison of responses of such devices to homologous anilines (p-methoxyaniline, p-fluoroaniline, and aniline) revealed that detection selectivity, determined by the ratio of μNPD to nonselective flame ionization detector (FID) peak areas, is correlated with acid disassociation pKa values for the respective analine. Selectivity was determined to be greatest for p-methoxyaniline, followed by p-fluoroaniline, with aniline having the smallest response. The limit of detection for a nitrogen containing chemical, p-methoxyaniline, using the μNPD was determined to be 0.29 ng compared to 59 ng for a carbon chemical containing no nitrogen or phosphorus, 1,3,5-trimethybenzene. The μNPD presented here has increased detection for nitrogen and phosphorus compared to the FID and with a slight increase in detection of carbon compounds compared to commercial NPD's sensitivity to nitrogen and carbon.

More Details

Genomics-enabled sensor platform for rapid detection of viruses related to disease outbreak

Brozik, Susan M.; Polsky, Ronen; Campbell, Deanna M.; Manginell, Ronald; Moorman, Matthew W.; Edwards, Thayne L.; Anderson, John M.; Pfeifer, Kent B.; Branch, Darren W.; Wheeler, David R.

More Details

Thermally-activated pentanol delivery from precursor poly(p- phenylenevinylene)s for MEMS lubrication

Macromolecular Rapid Communications

Johnson, Ross S.; Washburn, Cody; Staton, Alan W.; Moorman, Matthew W.; Manginell, Ronald; Dugger, Michael T.; Dirk, Shawn M.

The synthesis of two new polyphenylene vinylene (PPV) precursor polymers which can be thermally induced to eliminate pentanol is presented. Pentanol has recently been discovered to be a very useful lubricant in MicroElectroMechanical Systems. The utilization of the elimination reaction of precursor polymers to PPV as a small molecule delivery platform has, to the best of our knowledge, not been previously reported. The elimination reactions were examined using thermal gravimetric analysis, gas chromatography, and UV-Vis spectroscopy. Using PPV precursors allows for (1) a high loading of lubricant (one molecule per monomeric unit), (2) a platform that requires relatively high temperatures (>145 °C) to eliminate the lubricant, and (3) a non-volatile, mechanically and chemically stable by-product of the elimination reaction (PPV). The "on-demand" delivery of a vapor-phase lubricant to MicroElectoMechanical Systems (MEMS) will allow for scheduled or as-needed lubrication of the moving components, improving the performance, reliability, and lifespan of the devices. A delivery system utilizing a newly designed microhotplate along with two new precursor poly(p-phenylene vinylene) polymers that thermally eliminate a pentanol lubricant is described. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

More Details

Investigation of type-I interferon dysregulation by arenaviruses : a multidisciplinary approach

Branda, Catherine; James, Conrad D.; Kozina, Carol L.; Manginell, Ronald; Misra, Milind; Moorman, Matthew W.; Negrete, Oscar N.; Ricken, Bryce; Wu, Meiye

This report provides a detailed overview of the work performed for project number 130781, 'A Systems Biology Approach to Understanding Viral Hemorrhagic Fever Pathogenesis.' We report progress in five key areas: single cell isolation devices and control systems, fluorescent cytokine and transcription factor reporters, on-chip viral infection assays, molecular virology analysis of Arenavirus nucleoprotein structure-function, and development of computational tools to predict virus-host protein interactions. Although a great deal of work remains from that begun here, we have developed several novel single cell analysis tools and knowledge of Arenavirus biology that will facilitate and inform future publications and funding proposals.

More Details

Mass sensitive, Lorentz-Force actuated, MEMS preconcentrator and chemical sensor

ECS Transactions

Manginell, Ronald P.; Adkins, Douglas R.; Moorman, Matthew W.; Hadizadeh, Rameen; Copic, Davor; Porter, Daniel; Anderson, John M.; Wheeler, David R.; Pfeifer, Kent B.; Rumpf, Arthur

The mass-sensitive smart preconcentrator (SPC) consists of a Lorentz-Force-actuated MEMS resonator with an integral heater and surface coating for the collection of chemical analytes. Control circuitry is used to drive the SPC to resonance and measure its oscillation frequency. The frequency shift produced by adsorption of analyte on the SPC surface is inversely proportional to the mass of analyte collected. Thus, the SPC can measure when it has collected sufficient analyte for a downstream detection system. The limit of detection (LOD) of the SPC is less than 50 ppb for DMMP (dimethyl-methyl- phosphonate). At 1 ppm, less than 1 second collection of DMMP is sufficient to trigger analysis. An analytical model of operation of the SPC is used to predict the motion of the paddle and the shear modulus of silicon. © The Electrochemical Society.

More Details

Microfabricated chip for calibration of field instruments

2007 IEEE Conference on Technologies for Homeland Security: Enhancing Critical Infrastructure Dependability

Moorman, Matthew W.; Robinson, Alex; Manginell, Ronald; Tappan, Alexander S.; Linker, Kevin L.

Accurate, periodic calibration is required to operate IMS, GC, and portal security systems with maximum efficiency, surety, and operator confidence. To this end, we are presently developing a microfabricated device for on-demand calibration of fleldable contraband detection instruments. Using robotically-assisted picoliter dispensing methods, precise nanogram or larger amounts of calibration compound(s) are placed on micron-sized bridge structures. Resistively heating these structures delivers precisely quantified low-levels of calibration compounds to the detector systems. This provides reliable calibration for identification and quantification of explosives, narcotics, and other contraband. © 2007 IEEE.

More Details
Results 51–100 of 105
Results 51–100 of 105