Sandia National Laboratories Energy Storage Program Overview
Abstract not provided.
Abstract not provided.
Abstract not provided.
IEEE Power and Energy Society General Meeting
Extreme meteorological events, such as hurricanes and floods, cause significant infrastructure damage and, as a result, prolonged grid outages. To mitigate the negative effect of these outages and enhance the resilience of communities, microgrids consisting of solar photovoltaics (PV), energy storage (ES) technologies, and backup diesel generation are being considered. Furthermore, it is necessary to take into account how the extreme event affects the systems' performance during the outage, often referred to as black-sky conditions. In this paper, an optimization model is introduced to properly size ES and PV technologies to meet various duration of grid outages for selected critical infrastructure while considering black-sky conditions. A case study of the municipality of Villalba, Puerto Rico is presented to identify the several potential microgrid configurations that increase the community's resilience. Sensitivity analyses are performed around the grid outage durations and black-sky conditions to better decide what factors should be considered when scoping potential microgrids for community resilience.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
2021 Resilience Week, RWS 2021 - Proceedings
The US DOE Office of Electricity's Energy Storage Program's joint RD work with the Cordova Electric Cooperative (CEC) has deployed several advanced grid technologies that are providing benefits today to Cordova Alaska's electricity users. Advanced grid technologies deployed through DoE co-funded RD include a 1MW Battery Energy Storage System (BESS), and enhanced monitoring including Phasor Measurement Units (PMU's) to help better understand the operational impacts of the added BESS. This paper will highlight key accomplishments to-date in deploying and using advanced grid technologies, and then outline the next phase of work that will use these technologies to implement an operating scheme to reconfigure the utility's distribution system and utility resources including BESS to provide emergency back-up power to a critical load: The Cordova Community Medical Center (CCMC). This paper will include additional insights on the use of utility resources to support critical loads via case study examples by the National Rural Electric Cooperative Assoc. (NRECA).
A spreadsheet showing the final results from the ISO 55001 Section Alignment ratings is shown, including gap analysis and IAM maturity ratings.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.