Publications

Results 1–25 of 220

Search results

Jump to search filters

A data-driven multiscale model for reactive wetting simulations

Computers and Fluids

Horner, Jeffrey S.; Winter, Ian; Kemmenoe, David J.; Arata, Edward R.; Chandross, M.; Roberts, Scott A.; Grillet, Anne M.

We describe a data-driven, multiscale technique to model reactive wetting of a silver–aluminum alloy on a Kovar™ (Fe-Ni-Co alloy) surface. We employ molecular dynamics simulations to elucidate the dependence of surface tension and wetting angle on the drop's composition and temperature. A design of computational experiments is used to efficiently generate training data of surface tension and wetting angle from a limited number of molecular dynamics simulations. The simulation results are used to parameterize models of the material's wetting properties and compute the uncertainty in the models due to limited data. The data-driven models are incorporated into an engineering-scale (continuum) model of a silver–aluminum sessile drop on a Kovar™ substrate. Model predictions of the wetting angle are compared with experiments of pure silver spreading on Kovar™ to quantify the model-form errors introduced by the limited training data versus the simplifications inherent in the molecular dynamics simulations. The paper presents innovations in the determination of “convergence” of noisy MD simulations before they are used to extract the wetting angle and surface tension, and the construction of their models which approximate physio-chemical processes that are left unresolved by the engineering-scale model. Together, these constitute a multiscale approach that integrates molecular-scale information into continuum scale models.

More Details

Pressure-based process monitoring of direct-ink write material extrusion additive manufacturing

Additive Manufacturing

Kopatz, Jessica W.; Reinholtz, William; Cook, Adam W.; Tappan, Alexander S.; Grillet, Anne M.

As additive manufacturing (AM) has become a reliable method for creating complex and unique hardware rapidly, the quality assurance of printed parts remains a priority. In situ process monitoring offers an approach for performing quality control while simultaneously minimizing post-production inspection. For extrusion printing processes, direct linkages between extrusion pressure fluctuations and print defects can be established by integrating pressure sensors onto the print head. In this work, the sensitivity of process monitoring is tested using engineered spherical defects. Pressure and force sensors located near an ink reservoir and just before the nozzle are shown to assist in identification of air bubbles, changes in height between the print head and build surface, clogs, and particle aggregates with a detection threshold of 60–70% of the nozzle diameter. Visual evidence of printed bead distortion is quantified using optical image analysis and correlated to pressure measurements. Importantly, this methodology provides an ability to monitor the quality of AM parts produced by extrusion printing methods and can be accomplished using commonly available pressure-sensing equipment.

More Details

A level set approach for the computational study of a yield stress fluid filling a thin mold

Journal of Non-Newtonian Fluid Mechanics

Rao, Rekha R.; Cleaves, Helen L.; Grillet, Anne M.; Dey, Bikash; Mcconnell, Josh; McMaster, Anthony M.; Newell, Pania; Ortiz, Weston; Secor, Robert B.; Tjiptowidjojo, Kristianto

Many important engineering and scientific applications such as cement slurries, foams, crude oil, and granular avalanches involve the concept of yield stress. Therefore, modeling yield stress fluids in different flow configurations, including the accurate prediction of the yield surface, is important. In this paper, we present a computational model based on the finite element method to study the flow of yield stress fluids in a thin mold and compare the results with data from flow visualization experiments. We use the level set method to describe the interface between the filling fluid and air. We use polypropylene glycol as a model Newtonian fluid and Carbopol for the model yield stress fluid, as the Carbopol solution demonstrates yielding without thixotropy. To describe the yielding and shear-thinning behavior, we use a generalized Newtonian constitutive equation with a Bingham–Carreau–Yasuda form. We compare the results obtained from the mold filling experiments with the results from the three-dimensional (3D) model and from a reduced-order Hele-Shaw (HS) model that is two-dimensional, including the effect of shear-thinning along the thin direction only approximately. We show that both the 3D and the HS model can capture the experimental meniscus shape reasonably well for all the fluids considered at three different flow rates. This indicates that the shape evolution is insensitive to the dimensionality of the model. However, the viscosity and yield surfaces predicted by the 3D and HS models are different. The HS model underestimates the high viscosity and unyielded regions compared to the estimation by the 3D model.

More Details

Stress Birth and Death: Disruptive Computational Mechanics and Novel Diagnostics for Fluid-to-Solid Transitions

Rao, Rekha R.; McConnell, Joshua T.; Grillet, Anne M.; McMaster, Anthony M.; Cleaves, Helen L.; Roberts, Christine C.; Ortiz, Weston; Secor, Robert; Newell, Pania; Dey, Bikash; Rogers, Simon; Donley, Gavin; Kamani, Krutarth; Griebler, Jimmy

Many materials of interest to Sandia transition from fluid to solid or have regions of both phases coexisting simultaneously. Currently there are, unfortunately, no material models that can accurately predict this material response. This is relevant to applications that "birth stress" related to geoscience, nuclear safety, manufacturing, energy production and bioscience. Accurately capturing solidification and residual stress enables fully predictive simulations of the evolving front shape or final product. Accurately resolving flow of proppants or blood could reduce environmental impact or lead to better treatments for heart attacks, thrombosis, or aneurism. We will address a science question in this proposal: When does residual stress develop during the critical transition from liquid to solid and how does it affect material deformation? Our hypothesis is that these early phases of stress development are critical to predictive simulation of material performance, net shape, and aging. In this project, we use advanced constitutive models with yield stress to represent both fluid and solid behavior simultaneously. The report provides an abbreviated description of the results from our LDRD "Stress Birth and Death: Disruptive Computational Mechanics and Novel Diagnostics for Fluid-to-Solid Transitions," since we have written four papers that document the work in detail and which we reference. We give highlights of the work and describe the gravitationally driven flow visualization experiment on a model yield stress fluid, Carbopol, at various concentrations and flow rates. We were able to collapse the data on a single master curve by showing it was self-similar. We also describe the Carbopol rheology and the constitutive equations of interest including the Bingham-Carreau-Yasuda model, the Saramito model, and the HB-Saramito model including parameter estimation for the shear and oscillatory rheology. We present several computational models including the 3D moving mesh simulations of both the Saramito models and Bingham-Carreau-Yasuda (BCY) model. We also show results from the BCY model using a 3D level set method and two different ways of handling reduced order Hele-Shaw modeling for generalized Newtonian fluids. We present some first ever two-dimensional results for the modified Jeffries Kamani-Donley-Rogers constitutive equation developed during this project. We include some recent results with a successful Saramito-level set coupling that allows us to tackle problems with complex geometries like mold filling in a thin gap with an obstacle, without the need for remeshing or remapping. We report on some experiments for curing systems where fluorescent particles are used to track material flow. These experiments were carried out in an oven on Sylgard 184 as a model polymerizing system. We conclude the report with a summary of accomplishments and some thoughts on follow-on work.

More Details

Performance and electret charge of N95 respirators after decontamination [Slides]

Grillet, Anne M.; Storch, Steven M.; Nemer, Martin N.; Sanchez, A.L.; Laros, James H.; Piekos, Edward S.; Hurwitz, Ivy; Perkins, Douglas J.

Filtration, pressure drop and quantitative fit of N95 respirators were robust to several decontamination methods including vaporous hydrogen peroxide, wet heat, bleach, and ultraviolet light. Bleach may not have penetrated the hydrophobic outer layers of the N95 respirator. Isopropyl alcohol and detergent both severely degraded the electrostatic charge of the electret filtration layer. First data in N95 respirators that the loss of filtration efficiency was directly correlated with loss of surface potential on the filtration layer. The pressure drop was unchanged, so loss of filtration efficacy would not be apparent during a user seal check. Mechanical straps degrade with repeated mechanical cycling during extended use. Decontamination did not appear to degrade the elastic straps. Significant loss of strap elasticity would be apparent during a user negative pressure seal check.

More Details

Gamma radiation sterilization of N95 respirators leads to decreased respirator performance

PLoS ONE

Thelen, Paul M.; Grillet, Anne M.; Nemer, Martin N.; Olszewska-Wasiolek, Maryla A.; Hanson, Donald J.; Omana, Michael A.; Sanchez, A.L.; Vehar, David W.

In response to personal protective equipment (PPE) shortages in the United States due to the Coronavirus Disease 2019, two models of N95 respirators were evaluated for reuse after gamma radiation sterilization. Gamma sterilization is attractive for PPE reuse because it can sterilize large quantities of material through hermetically sealed packaging, providing safety and logistic benefits. The Gamma Irradiation Facility at Sandia National Laboratories was used to irradiate N95 filtering facepiece respirators to a sterilization dose of 25 kGy(tissue). Aerosol particle filtration performance testing and electrostatic field measurements were used to determine the efficacy of the respirators after irradiation. Both respirator models exhibited statistically significant decreases in particle filtering efficiencies and electrostatic potential after irradiation. The largest decrease in capture efficiency was 40–50% and peaked near the 200 nm particle size. The key contribution of this effort is correlating the electrostatic potential change of individual filtration layer of the respirator with the decrease filtration efficiency after irradiation. This observation occurred in both variations of N95 respirator that we tested. Electrostatic potential measurement of the filtration layer is a key indicator for predicting filtration efficiency loss.

More Details

COVID-19 global pandemic planning: Performance and electret charge of N95 respirators after recommended decontamination methods

Experimental Biology and Medicine

Grillet, Anne M.; Nemer, Martin N.; Storch, Steven M.; Martinez-Sanchez, Andres M.; Piekos, Edward S.; Leonard, Jonathan C.; Hurwitz, Ivy; Perkins, Douglas J.

Shortages of N95 respirators for use by medical personnel have driven consideration of novel conservation strategies, including decontamination for reuse and extended use. Decontamination methods listed as promising by the Centers for Disease Control and Prevention (CDC) (vaporous hydrogen peroxide (VHP), wet heat, ultraviolet irradiation (UVI)) and several methods considered for low resource environments (bleach, isopropyl alcohol and detergent/soap) were studied for two commonly used surgical N95 respirators (3M™ 1860 and 1870+ Aura™). Although N95 filtration performance depends on the electrostatically charged electret filtration layer, the impact of decontamination on this layer is largely unexplored. As such, respirator performance following decontamination was assessed based on the fit, filtration efficiency, and pressure drop, along with the relationship between (1) surface charge of the electret layer, and (2) elastic properties of the straps. Decontamination with VHP, wet heat, UVI, and bleach did not degrade fit and filtration performance or electret charge. Isopropyl alcohol and soap significantly degraded fit, filtration performance, and electret charge. Pressure drop across the respirators was unchanged. Modest degradation of N95 strap elasticity was observed in mechanical fatigue testing, a model for repeated donnings and doffings. CDC recommended decontamination methods including VHP, wet heat, and UV light did not degrade N95 respirator fit or filtration performance in these tests. Extended use of N95 respirators may degrade strap elasticity, but a loss of face seal integrity should be apparent during user seal checks. NIOSH recommends performing user seal checks after every donning to detect loss of appropriate fit. Decontamination methods which degrade electret charge such as alcohols or detergents should not be used on N95 respirators. The loss of N95 performance due to electret degradation would not be apparent to a respirator user or evident during a negative pressure user seal check.

More Details
Results 1–25 of 220
Results 1–25 of 220