Laboratory Generated Photoionization Fronts Relevant to Astrophysics
Abstract not provided.
Abstract not provided.
Abstract not provided.
Opacity-on-NIF has obtained opacity data under conditions similar to those achieved by the entirely different Opacity-on-Z platform. From low- and high-Z elements at different anchor points, rigorously compare the opacity data between the laboratories and to multiple opacity theory models. Compare and assess the data acquisition and processing methods for obtaining opacities and for measuring/inferring sample conditions. Explain, or develop hypotheses for, any discrepancies. Map progress to the National Opacity Strategy and define future directions.
This project applies methods in Bayesian inference and modern statistical methods to quantify the value of new experimental data, in the form of new or modified diagnostic configurations and/or experiment designs. We demonstrate experiment design methods that can be used to identify the highest priority diagnostic improvements or experimental data to obtain in order to reduce uncertainties on critical inferred experimental quantities and select the best course of action to distinguish between competing physical models. Bayesian statistics and information theory provide the foundation for developing the necessary metrics, using two high impact experimental platforms on Z as exemplars to develop and illustrate the technique. We emphasize that the general methodology is extensible to new diagnostics (provided synthetic models are available), as well as additional platforms. We also discuss initial scoping of additional applications that began development in the last year of this LDRD.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Predictive design of REHEDS experiments with radiation-hydrodynamic simulations requires knowledge of material properties (e.g. equations of state (EOS), transport coefficients, and radiation physics). Interpreting experimental results requires accurate models of diagnostic observables (e.g. detailed emission, absorption, and scattering spectra). In conditions of Local Thermodynamic Equilibrium (LTE), these material properties and observables can be pre-computed with relatively high accuracy and subsequently tabulated on simple temperature-density grids for fast look-up by simulations. When radiation and electron temperatures fall out of equilibrium, however, non-LTE effects can profoundly change material properties and diagnostic signatures. Accurately and efficiently incorporating these non-LTE effects has been a longstanding challenge for simulations. At present, most simulations include non-LTE effects by invoking highly simplified inline models. These inline non-LTE models are both much slower than table look-up and significantly less accurate than the detailed models used to populate LTE tables and diagnose experimental data through post-processing or inversion. Because inline non-LTE models are slow, designers avoid them whenever possible, which leads to known inaccuracies from using tabular LTE. Because inline models are simple, they are inconsistent with tabular data from detailed models, leading to ill-known inaccuracies, and they cannot generate detailed synthetic diagnostics suitable for direct comparisons with experimental data. This project addresses the challenge of generating and utilizing efficient, accurate, and consistent non-equilibrium material data along three complementary but relatively independent research lines. First, we have developed a relatively fast and accurate non-LTE average-atom model based on density functional theory (DFT) that provides a complete set of EOS, transport, and radiative data, and have rigorously tested it against more sophisticated first-principles multi-atom DFT models, including time-dependent DFT. Next, we have developed a tabular scheme and interpolation methods that compactly capture non-LTE effects for use in simulations and have implemented these tables in the GORGON magneto-hydrodynamic (MHD) code. Finally, we have developed post-processing tools that use detailed tabulated non-LTE data to directly predict experimental observables from simulation output.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Physics of Plasmas
Here we present a new analysis methodology that allows for the self-consistent integration of multiple diagnostics including nuclear measurements, x-ray imaging, and x-ray power detectors to determine the primary stagnation parameters, such as temperature, pressure, stagnation volume, and mix fraction in magnetized liner inertial fusion (MagLIF) experiments. The analysis uses a simplified model of the stagnation plasma in conjunction with a Bayesian inference framework to determine the most probable configuration that describes the experimental observations while simultaneously revealing the principal uncertainties in the analysis. We validate the approach by using a range of tests including analytic and three-dimensional MHD models. An ensemble of MagLIF experiments is analyzed, and the generalized Lawson criterion χ is estimated for all experiments.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Journal of Physics B: Atomic, Molecular and Optical Physics
Spectral line-shape models are an important part of understanding high-energy-density (HED) plasmas. Models are needed for calculating opacity of materials and can serve as diagnostics for astrophysical and laboratory plasmas. However, much of the literature on line shapes is directed toward specialists. This perspective makes it difficult for non-specialists to enter the field. We have two broad goals with this topical review. First, we aim to give information so that others in HED physics may better understand the current field. This first goal may help guide future experiments to test different aspects of the theory. Second, we provide an introduction for those who might be interested in line-shape theory, and enough materials to be able to navigate the field and the literature. We give a high-level overview of line broadening process, as well as dive into the formalism, available methods, and approximations.
Abstract not provided.
Physical Review Letters
Understanding how atoms interact with hot dense matter is essential for astrophysical and laboratory plasmas. Interactions in high-density plasmas broaden spectral lines, providing a rare window into interactions that govern, for example, radiation transport in stars. However, up to now, spectral line-shape theories employed at least one of three common approximations: second-order Taylor treatment of broadening operator, dipole-only interactions between atom and plasma, and classical treatment of perturbing electrons. In this Letter, we remove all three approximations simultaneously for the first time and test the importance for two applications: neutral hydrogen and highly ionized magnesium and oxygen. We found 15%-50% change in the spectral line widths, which are sufficient to impact applications including white-dwarf mass determination, stellar-opacity research, and laboratory plasma diagnostics.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Review of Scientific Instruments
Laboratory experiments typically test opacity models by measuring spectrally resolved transmission of a sample using bright backlight radiation. A potential problem is that any unaccounted background signal contaminating the spectrum will artificially reduce the inferred opacity. Methods developed to measure background signals in opacity experiments at the Sandia Z facility are discussed. Preliminary measurements indicate that backgrounds are 9%-11% of the backlight signal at wavelengths less than 10 Å. Background is thus a relatively modest correction for all Z opacity data published to date. Future work will determine how important background is at longer wavelengths.
Abstract not provided.
Abstract not provided.
Physics of Plasmas
White Dwarf (WD) stars are the most common stellar remnant in the universe. WDs usually have a hydrogen or helium atmosphere, and helium WD (called DB) spectra can be used to solve outstanding problems in stellar and galactic evolution. DB origins, which are still a mystery, must be known to solve these problems. DB masses are crucial for discriminating between different proposed DB evolutionary hypotheses. Current DB mass determination methods deliver conflicting results. The spectroscopic mass determination method relies on line broadening models that have not been validated at DB atmosphere conditions. We performed helium benchmark experiments using the White Dwarf Photosphere Experiment (WDPE) platform at Sandia National Laboratories' Z-machine that aims to study He line broadening at DB conditions. Using hydrogen/helium mixture plasmas allows investigating the importance of He Stark and van der Waals broadening simultaneously. Accurate experimental data reduction methods are essential to test these line-broadening theories. In this paper, we present data calibration methods for these benchmark He line shape experiments. We give a detailed account of data processing, spectral power calibrations, and instrument broadening measurements. Uncertainties for each data calibration step are also derived. We demonstrate that our experiments meet all benchmark experiment accuracy requirements: WDPE wavelength uncertainties are <1 Å, spectral powers can be determined to within 15%, densities are accurate at the 20% level, and instrumental broadening can be measured with 20% accuracy. Fulfilling these stringent requirements enables WDPE experimental data to provide physically meaningful conclusions about line broadening at DB conditions.
Abstract not provided.
Abstract not provided.
I am a staff scientist at Sandia National Laboratories (SNL). I work on multiple fundamental-science projects and lead modeling/data-analysis for the stellar opacity experiments. I also work with theorists to refine plasma material-property calculations to make NNSA simulations more predictable. These are challenging and important problems for national security. In fact, our experiments raised questions about “opacity”, the property of matter that controls energy transport inside stars. This work was published by Nature due to its serious implication over broad applications, and our team received NNSA Defense Program Award of Excellence, both in 2015. Work at SNL is collegial and full of learning through interactions with the world’s finest experimentalists and theorists. When I started my Ph.D. program, working at a national lab was a dream position. Today, I collaborate with top scientists to solve mission-critical problems. The Stewardship Science Academic Programs (SSAP) and National Laser Users’ Facility (NLUF) played a vital role in the efficient learning and seamless transition to SNL.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Physics of Plasmas
The magnetized liner inertial fusion (MagLIF) scheme relies on coupling laser energy into an underdense fuel raising the fuel adiabat at the start of the implosion. To deposit energy into the fuel, the laser must first penetrate a laser entrance hole (LEH) foil which can be a significant energy sink and introduce mix. In this paper, we report on experiments investigating laser energy coupling into MagLIF-relevant gas cell targets with LEH foil thicknesses varying from 0.5 μm to 3 μm. Two-dimensional (2D) axisymmetric simulations match the experimental results well for 0.5 μm and 1 μm thick LEH foils but exhibit whole-beam self-focusing and excessive penetration of the laser into the gas for 2 μm and 3 μm thick LEH foils. Better agreement for the 2 μm-thick foil is found when using a different thermal conductivity model in 2D simulations, while only 3D Cartesian simulations come close to matching the 3 μm-thick foil experiments. The study suggests that simulations may over-predict the tendency for the laser to self-focus during MagLIF preheat when thicker LEH foils are used. This effect is pronounced with 2D simulations where the azimuthally symmetric density channel effectively self-focuses the rays that are forced to traverse the center of the plasma. The extra degree of freedom in 3D simulations significantly reduces this effect. The experiments and simulations also suggest that, in this study, the amount of energy coupled into the gas is highly correlated with the laser propagation length regardless of the LEH foil thickness.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Physical Review Letters
Accurate calculation of spectral line broadening is important for many hot, dense plasma applications. However, calculated line widths have significantly underestimated measured widths for Δn=0 lines of Li-like ions, which is known as the isolated-line problem. In this Letter, scrutinization of the line-width derivation reveals that the commonly used expression neglects a potentially important contribution from electron-capture. Line-width calculations including this process are performed with two independent codes, both of which removed the discrepancies at temperatures below 10 eV. The revised calculations also suggest the remaining discrepancy scales more strongly with electron temperature than the atomic number as was previously suggested.
The Astrophysical Journal (Online)
The spectroscopic method relies on hydrogen Balmer absorption lines to infer white dwarf (WD) masses. These masses depend on the choice of atmosphere model, hydrogen atomic line shape calculation, and which Balmer series members are included in the spectral fit. In addition to those variables, spectroscopic masses disagree with those derived using other methods. In this article, we present laboratory experiments aimed at investigating the main component of the spectroscopic method: hydrogen line shape calculations. These experiments use X-rays from Sandia National Laboratories' Z-machine to create a uniform ~15 cm3 hydrogen plasma and a ~4 eV backlighter that enables recording high-quality absorption spectra. The large plasma, volumetric X-ray heating that fosters plasma uniformity, and the ability to collect absorption spectra at WD photosphere conditions are improvements over past laboratory experiments. Analysis of the experimental absorption spectra reveals that electron density (${n}_{{\rm{e}}}$) values derived from the Hγ line are ~34% ± 7.3% lower than from Hβ. Two potential systematic errors that may contribute to this difference were investigated. A detailed evaluation of self-emission and plasma gradients shows that these phenomena are unlikely to produce any measurable Hβ–Hγ ${n}_{{\rm{e}}}$ difference. WD masses inferred with the spectroscopic method are proportional to the photosphere density. Hence, the measured Hβ–Hγ ${n}_{{\rm{e}}}$ difference is qualitatively consistent with the trend that WD masses inferred from their Hβ line are higher than that resulting from the analysis of Hβ and Hγ. This evidence may suggest that current hydrogen line shape calculations are not sufficiently accurate to capture the intricacies of the Balmer series.