Development of Elastic Recoil Detection Technique for Quantifying Light Isotope Concentrations in Irradiated TPBAR Materials

Doyle, Barney L.; Bays, Nathan R.; Hattar, Khalid; Muntifering, Brittany R.

The National Nuclear Security Administration's Tritium Sustainment Program is responsible for the design, development, demonstration, testing, analysis, and characterization of tritium-producing burnable absorber rods (TPBARs) and their components, in addition to producing tritium for the nation's strategic stockpile. The FY18 call for proposals included the specific basic science research topic, "Demonstration and evaluation of advanced characterization methods, particularly for quantifying the concentration of light isotopes (1H, 2H, and 4He, 6Li, and 7Li) in metal or ceramic matrices". A project IWO-389859 was awarded to the Ion Beam Lab (IBL) at Sandia-NM in FY18. This reports the success we had in developing and demonstrating such a method: 42 MeV Si+ 7 from the IBL' s Tandem was used to recoil these light isotopes into special detectors that separated all these isotopes by simultaneously measuring the energy and stopping power of these reoils. This technique, called Heavy Ion - Elastic Recoil Detection or HI-ERD, accurately measured the enriched 6 Li/Li-total of 0.246 +- 0.016, compared to the known value of 0.239. The isotopes 1H, 2H, 4He, 6Li and 7Li were also measured. (page intentionally left blank)

More Details

Metal Hydride Compression

Johnson, Terry; Bays, Nathan R.; Bowman, Robert C.; Smith, Barton D.; Jensen, Craig

Conventional hydrogen compressors often contribute over half of the cost of hydrogen stations, have poor reliability, and have insufficient flow rates for a mature fuel cell vehicle market. Fatigue associated with their moving parts including cracking of diaphragms and failure of seals leads to failure in conventional compressors, which is exacerbated by the repeated starts and stops expected at fueling stations. Furthermore, the conventional lubrication of these compressors with oil is generally unacceptable at fueling stations due to potential fuel contamination. MH technology offers a very good alternative to both conventional (mechanical) and newly developed (electrochemical, ionic liquid pistons) methods of hydrogen compression. Advantages of MH compression include simplicity in design and operation, absence of moving parts, compactness, safety and reliability, and the possibility to utilize waste industrial heat to power the compressor. Beyond conventional H2 supply via pipelines or tanker trucks, another attractive scenario is the on-site generation and delivery of pure H2 at pressure (> 875 bar) for refueling vehicles at electrolysis, wind, or solar H2 production facilities in distributed locations that are too remote or widely distributed for cost effective bulk transport. MH hydrogen compression utilizes a reversible heat-driven interaction of a hydride-forming metal alloy with hydrogen gas to form the MH phase and is a promising process for hydrogen energy applications. To deliver hydrogen continuously, each stage of the compressor must consist of multiple MH beds with synchronized hydrogenation & dehydrogenation cycles. Multistage pressurization allows achievement of greater compression ratios using reduced temperature swings compared to single stage compressors. The objectives of this project are to investigate and demonstrate on a laboratory scale a twostage MH hydrogen gas compressor with a feed pressure of >100 bar and a delivery pressure > 875 bar of high purity H2 gas using the scheme shown in Figure 1. Progress to date includes the selection of metal hydrides for each compressor stage based on experimental characterization of their thermodynamics, kinetics, and hydrogen capacities for optimal performance with respect to energy requirements and efficiency. Additionally, final bed designs have been completed based on trade studies and all components have been ordered. The prototype two-stage compressor will be fabricated, assembled, and experimentally evaluated in FY19.

More Details

Limiting noise fraction in PDV measurements

Bays, Nathan R.

The limiting frequency resolution of a PDV measurement is: σf = $\sqrt\frac{6 η}{fsτ^3π}$ where fs is the sample rate, τ is the analysis time duration, and 11 is the noise fraction. Although T is a strong lever for reducing uncertainty, this parameter must be kept small to preserve time resolution. Consider a PDV measurement with sampled at 80 GS/s and analyzed in 1 ns durations. A 1% noise fraction corresponds to 0.87 MHz of frequency uncertainty, which at 1550 nm works out to 0.68 m/s. A 10% noise fraction has a limiting velocity resolution of about 7 m/s; for comparison, a VISAR system with similar response time (0.5 ns delay, 532 m/s fringe constant) would have a limiting uncertainty of 5-6 m/s. Noise fractions of 10-20% or less are desirable for measurements at this time scale.

More Details

Characterizing MPI matching via trace-based simulation

Parallel Computing

Ferreira, Kurt B.; Levy, Scott; Bays, Nathan R.; Grant, Ryan

With the increased scale expected on future leadership-class systems, detailed information about the resource usage and performance of MPI message matching provides important insights into how to maintain application performance on next-generation systems. However, obtaining MPI message matching performance data is often not possible without significant effort. A common approach is to instrument an MPI implementation to collect relevant statistics. While this approach can provide important data, collecting matching data at runtime perturbs the application's execution, including its matching performance, and is highly dependent on the MPI library's matchlist implementation. In this paper, we introduce a trace-based simulation approach to obtain detailed MPI message matching performance data for MPI applications without perturbing their execution. Using a number of key parallel workloads and microbenchmarks, we demonstrate that this simulator approach can rapidly and accurately characterize matching behavior. Specifically, we use our simulator to collect several important statistics about the operation of the MPI posted and unexpected queues. For example, we present data about search lengths and the duration that messages spend in the queues waiting to be matched. Data gathered using this simulation-based approach have significant potential to aid hardware designers in determining resource allocation for MPI matching functions and provide application and middleware developers with insight into the scalability issues associated with MPI message matching.

More Details

FY18 L2 Milestone #6360 Report: Initial Capability of an Arm-based Advanced Architecture Prototype System and Software Environment

Bays, Nathan R.; Bays, Nathan R.; Hammond, Simon; Aguilar, Michael J.; Curry, Matthew L.; Grant, Ryan; Hoekstra, Robert J.; Klundt, Ruth A.; Monk, Stephen T.; Ogden, Jeffry B.; Olivier, Stephen L.; Scott, Randall D.; Ward, Harry L.; Younge, Andrew J.

The Vanguard program informally began in January 2017 with the submission of a white paper entitled "Sandia's Vision for a 2019 Arm Testbed" to NNSA headquarters. The program proceeded in earnest in May 2017 with an announcement by Doug Wade (Director, Office of Advanced Simulation and Computing and Institutional R&D at NNSA) that Sandia National Laboratories (Sandia) would host the first Advanced Architecture Prototype platform based on the Arm architecture. In August 2017, Sandia formed a Tri-lab team chartered to develop a robust HPC software stack for Astra to support the Vanguard program goal of demonstrating the viability of Arm in supporting ASC production computing workloads. This document describes the high-level Vanguard program goals, the Vanguard-Astra project acquisition plan and procurement up to contract placement, the initial software stack environment planned for the Vanguard-Astra platform (Astra), a description of how the communities of users will utilize the platform during the transition from the open network to the classified network, and initial performance results.

More Details

Recent Diagnostic Platform Accomplishments for Studying Vacuum Power Flow Physics at the Sandia Z Accelerator

Laity, George R.; Aragon, Carlos; Bennett, Nichelle L.; Bliss, David E.; Bays, Nathan R.; Fierro, Andrew S.; Gomez, Matthew R.; Hess, Mark H.; Hutsel, Brian T.; Jennings, Christopher A.; Johnston, Mark D.; Kossow, Michael R.; Lamppa, Derek C.; Martin, Matthew R.; Patel, Sonal G.; Porwitzky, A.; Robinson, Allen C.; Rose, David; Vandevender, Pace; Waisman, Eduardo M.; Webb, Timothy J.; Welch, Dale; Rochau, Gregory A.; Savage, Mark E.; Stygar, William; White, William M.; Sinars, Daniel; Cuneo, Michael E.

Abstract not provided.

Large-Scale System Monitoring Experiences and Recommendations

Ahlgren, V.; Andersson, S.; Brandt, James M.; Cardo, N.; Chunduri, S.; Enos, J.; Fields, P.; Gentile, Ann C.; Gerber, R.; Gienger, M.; Greenseid, J.; Greiner, A.; Hadri, B.; He, Y.; Hoppe, D.; Kaila, U.; Kelly, K.; Klein, M.; Kristiansen, A.; Leak, S.; Mason, M.; Bays, Nathan R.; Piccinali, J-G; Repik, Jason J.; Rogers, J.; Salminen, S.; Showerman, M.; Whitney, C.; Williams, J.

Abstract not provided.