Publications

Results 1–25 of 59

Search results

Jump to search filters

Bayesian optimal experimental design for constitutive model calibration

International Journal of Mechanical Sciences

Ricciardi, Denielle; Seidl, Daniel T.; Lester, Brian T.; Jones, Elizabeth M.; Jones, Amanda

Computational simulation is increasingly relied upon for high/consequence engineering decisions, which necessitates a high confidence in the calibration of and predictions from complex material models. However, the calibration and validation of material models is often a discrete, multi-stage process that is decoupled from material characterization activities, which means the data collected does not always align with the data that is needed. To address this issue, an integrated workflow for delivering an enhanced characterization and calibration procedure—Interlaced Characterization and Calibration (ICC)—is introduced and demonstrated. Further, this framework leverages Bayesian optimal experimental design (BOED), which creates a line of communication between model calibration needs and data collection capabilities in order to optimize the information content gathered from the experiments for model calibration. Eventually, the ICC framework will be used in quasi real-time to actively control experiments of complex specimens for the calibration of a high-fidelity material model. This work presents the critical first piece of algorithm development and a demonstration in determining the optimal load path of a cruciform specimen with simulated data. Calibration results, obtained via Bayesian inference, from the integrated ICC approach are compared to calibrations performed by choosing the load path a priori based on human intuition, as is traditionally done. The calibration results are communicated through parameter uncertainties which are propagated to the model output space (i.e. stress–strain). In these exemplar problems, data generated within the ICC framework resulted in calibrated model parameters with reduced measures of uncertainty compared to the traditional approaches.

More Details

Toward accurate prediction of partial-penetration laser weld performance informed by three-dimensional characterization – Part II: μCT based finite element simulations

Tomography of Materials and Structures

Skulborstad, Alyssa J.; Madison, Jonathan D.; Polonsky, Andrew P.; Jin, Huiqing J.; Jones, Amanda; Sanborn, Brett S.; Kramer, Sharlotte L.; Antoun, Bonnie R.; Lu, Wei-Yang L.; Karlson, Kyle N.

The mechanical behavior of partial-penetration laser welds exhibits significant variability in engineering quantities such as strength and apparent ductility. Understanding the root cause of this variability is important when using such welds in engineering designs. In Part II of this work, we develop finite element simulations with geometry derived from micro-computed tomography (μCT) scans of partial-penetration 304L stainless steel laser welds that were analyzed in Part I. We use these models to study the effects of the welds’ small-scale geometry, including porosity and weld depth variability, on the structural performance metrics of weld ductility and strength under quasi-static tensile loading. We show that this small-scale geometry is the primary cause of the observed variability for these mechanical response quantities. Additionally, we explore the sensitivity of model results to the conversion of the μCT data to discretized model geometry using different segmentation algorithms, and to the effect of small-scale geometry simplifications for pore shape and weld root texture. The modeling approach outlined and results of this work may be applicable to other material systems with small-scale geometric features and defects, such as additively manufactured materials.

More Details

Combined thermographic phosphor and digital image correlation (TP + DIC) for simultaneous temperature and strain measurements

Strain

Jones, Elizabeth M.; Jones, Amanda; Winters, Caroline W.

Thermographic phosphors (TP) are combined with stereo digital image correlation (DIC) in a novel diagnostic, TP + DIC, to measure full-field surface strains and temperatures simultaneously. The TP + DIC method is presented, including corrections for nonlinear CMOS camera detectors and generation of pixel-wise calibration curves to relate the known temperature to the ratio of pixel intensities between two distinct wavelength bands. Additionally, DIC is employed not only for strain measurements but also for accurate image registration between the two cameras for the two-colour ratio method approach of phosphoric thermography. TP + DIC is applied to characterize the thermo-mechanical response of 304L stainless steel dog bones during tensile testing at different strain rates. The dog bones are patterned for DIC with Mg3F2GeO4:Mn (MFG) via aerosol deposition through a shadow mask. Temperatures up to 425°K (150°C) and strains up to 1.0 mm/mm are measured in the localized necking region, with conservative noise levels of 10°K and 0.01 mm/mm or less. Finally, TP + DIC is compared to the more established method of combining infrared (IR) thermography with DIC (IR + DIC), with results agreeing favourably. Three topics of continued research are identified, including cracking of the aerosol-deposited phosphor DIC features, incomplete illumination for pixels on the border of the phosphor features, and phosphor emission evolution as a function of applied substrate strain. This work demonstrates the combination of phosphor thermography and DIC and lays the foundation for further development of TP + DIC for testing in combined thermo-mechancial environments.

More Details

304L Can Crush Validation Studies

Lao, Xai; Antoun, Bonnie R.; Jones, Amanda; Mac Donald, Kimberley A.; Stershic, Andrew J.; Talamini, Brandon

Accurate prediction of ductile behavior of structural alloys up to and including failure is essential in component or system failure assessment, which is necessary for nuclear weapons alteration and life extensions programs of Sandia National Laboratories. Modeling such behavior requires computational capabilities to robustly capture strong nonlinearities (geometric and material), rate- dependent and temperature-dependent properties, and ductile failure mechanisms. This study's objective is to validate numerical simulations of a high-deformation crush of a stainless steel can. The process consists of identifying a suitable can geometry and loading conditions, conducting the laboratory testing, developing a high-quality Sierra/SM simulation, and then drawing comparisons between model and measurement to assess the fitness of the simulation in regards to material model (plasticity), finite element model construction, and failure model. Following previous material model calibration, a J2 plasticity model with a microstructural BCJ failure model is employed to model the test specimen made of 304L stainless steel. Simulated results are verified and validated through mesh and mass-scaling convergence studies, parameter sensitivity studies, and a comparison to experimental data. The converged mesh and degree of mass-scaling are the mesh discretization with 140,372 elements, and a mass scaling with a target time increment of 1.0e-6 seconds and time step scale factor of 0.5, respectively. Results from the coupled thermal-mechanical explicit dynamic analysis are comparable to the experimental data. Simulated global force vs displacement (F/D) response predicts key points such as yield, ultimate, and kinks of the experimental F/D response. Furthermore, the final deformed shape of the can and field data predicted from the analysis are similar to that of the deformed can, as measured by 3D optical CMM scans and DIC data from the experiment.

More Details

Advances in phosphor two-color ratio method thermography for full-field surface temperature measurements

Measurement Science and Technology

Jones, Elizabeth M.; Jones, Amanda; Hoffmeister, Kathryn N.; Winters, Caroline W.

Thermographic phosphors can be employed for optical sensing of surface, gas phase, and bulk material temperatures through different strategies including the time-decay method, time-integrated method, and frequency-domain method. We focus on the time-integrated method, also known as the ratio method, as it can be more practical in many situations. This work advances the ratio method using two machine vision cameras with CMOS detectors for full-field temperature measurements of a solid surface. A phosphor calibration coupon is fabricated using aerosol deposition and employed for in situ determination of the temperature-versus-intensity ratio relationship. Algorithms from digital image correlation are employed to determine the stereoscopic imaging system intrinsic and extrinsic parameters, and accurately register material points on the sample to subpixel locations in each image with 0.07 px or better accuracy. Detector nonlinearity is carefully characterized and corrected. Temperature-dependent, spatial non-uniformity of the full-field intensity ratio-posited to be caused by a blue-shift effect of the bandpass filter for non-collimated light and/or a wavelength-dependent transmission efficiency of the lens-is assessed and treated for cases where a standard flat-field correction fails to correct the non-uniformity. In sum, pixel-wise calibration curves relating the computed intensity ratio to temperature in the range of T = 300-430 K are generated, with an embedded error of less than 3 K. This work offers a full calibration methodology and several improvements on two-color phosphor thermography, opening the door for full-field temperature measurements in dynamic tests with deforming test articles.

More Details
Results 1–25 of 59