Publications

12 Results

Search results

Jump to search filters

Z-Beamlet: a multi-KJ TW-class laser for backlit x-radiography applications on the Z-Accelerator

Atherton, B.W.; Gonzales, Rita A.; Gurrieri, Thomas G.; Herrmann, Mark H.; Mulville, Thomas D.; Neely, Kelly A.; Rambo, Patrick K.; Rovang, Dean C.; Ruggles, Larry R.; Smith, Ian C.; Schwarz, Jens S.; Simpson, Walter W.; Sinars, Daniel S.; Speas, Christopher S.; Tafoya-Porras, Belinda T.; Wenger, D.F.; Young, Ralph W.; Adams, Richard G.; Bennett, Guy R.; Campbell, David V.; Carroll, Malcolm; Claus, Liam D.; Edens, Aaron E.; Geissel, Matthias G.

Abstract not provided.

X-ray optics on the Z-Accelerator backlit with the Z-Beamlet Laser & Z-Petawatt Laser systems

Gonzales, Rita A.; Gurrieri, Thomas G.; Herrmann, Mark H.; Mulville, Thomas D.; Neely, Kelly A.; Rambo, Patrick K.; Rovang, Dean C.; Ruggles, Larry R.; Schwarz, Jens S.; Adams, Richard G.; Simpson, Walter W.; Sinars, Daniel S.; Smith, Ian C.; Speas, Christopher S.; Tafoya-Porras, Belinda T.; Wenger, D.F.; Young, Ralph W.; Edens, Aaron E.; Atherton, B.W.; Bennett, Guy R.; Campbell, David V.; Carroll, Malcolm; Claus, Liam D.; Geissel, Matthias G.

Abstract not provided.

1- and 2-frame monochromatic x-ray imaging of NIF-like capsules on Z and future higher-energy higher-resolution 2- & 4-frame x-radiography plans for ZR

Bennett, Guy R.; Campbell, David V.; Claus, Liam D.; Foresi, James S.; Johnson, Drew J.; Jones, Michael J.; Keller, Keith L.; Leifeste, Gordon T.; McPherson, Leroy A.; Mulville, Thomas D.; Neely, Kelly A.; Sinars, Daniel S.; Herrmann, Mark H.; Rambo, Patrick K.; Rovang, Dean C.; Ruggles, Larry R.; Simpson, Walter W.; Speas, Christopher S.; Wenger, D.F.; Smith, Ian C.; Cuneo, M.E.; Adams, Richard G.; Atherton, B.W.; Barnard, Wilson J.; Beutler, David E.; Burr, Robert A.

Abstract not provided.

Measurement of the energy and power radiated by a pulsed blackbody x-ray source

Proposed for publication in Physical Review E.

Stygar, William A.; Leeper, Ramon J.; Mazarakis, Michael G.; McDaniel, Dillon H.; Mckenney, John M.; Mills, Jerry A.; Ruggles, Larry R.; Seamen, Johann F.; Simpson, Walter W.; Dropinski, Steven D.; Warne, Larry K.; York, Matthew W.; McGurn, John S.; Bryce, Edwin A.; Chandler, Gordon A.; Cuneo, M.E.; Johnson, William Arthur.; Jorgenson, Roy E.

We have developed a diagnostic system that measures the spectrally integrated (i.e. the total) energy and power radiated by a pulsed blackbody x-ray source. The total-energy-and-power (TEP) diagnostic system is optimized for blackbody temperatures between 50 and 350 eV. The system can view apertured sources that radiate energies and powers as high as 2 MJ and 200 TW, respectively, and has been successfully tested at 0.84 MJ and 73 TW on the Z pulsed-power accelerator. The TEP system consists of two pinhole arrays, two silicon-diode detectors, and two thin-film nickel bolometers. Each of the two pinhole arrays is paired with a single silicon diode. Each array consists of a 38 x 38 square array of 10-{micro}m-diameter pinholes in a 50-{micro}m-thick tantalum plate. The arrays achromatically attenuate the x-ray flux by a factor of {approx}1800. The use of such arrays for the attenuation of soft x rays was first proposed by Turner and co-workers [Rev. Sci. Instrum. 70, 656 (1999)RSINAK0034-674810.1063/1.1149385]. The attenuated flux from each array illuminates its associated diode; the diode's output current is recorded by a data-acquisition system with 0.6-ns time resolution. The arrays and diodes are located 19 and 24 m from the source, respectively. Because the diodes are designed to have an approximately flat spectral sensitivity, the output current from each diode is proportional to the x-ray power. The nickel bolometers are fielded at a slightly different angle from the array-diode combinations, and view (without pinhole attenuation) the same x-ray source. The bolometers measure the total x-ray energy radiated by the source and--on every shot--provide an in situ calibration of the array-diode combinations. Two array-diode pairs and two bolometers are fielded to reduce random uncertainties. An analytic model (which accounts for pinhole-diffraction effects) of the sensitivity of an array-diode combination is presented.

More Details

[Copy of characteristics and scaling of tungsten-wire-array z-pinch implosion dynamics at 20 MA.]

Proposed for publication in Physics of Plasmas.

Vesey, Roger A.; Yu, Edmund Y.; Nash, Thomas J.; Bliss, David E.; Bennett, Guy R.; Sinars, Daniel S.; Simpson, Walter W.; Ruggles, Larry R.; Wenger, D.F.; Garasi, Christopher J.; Aragon, Rafael A.; Fowler, William E.; Johnson, Drew J.; Keller, Keith L.; McGurn, John S.; Mehlhorn, Thomas A.; Speas, Christopher S.; Struve, Kenneth W.; Stygar, William A.; Chandler, Gordon A.

Abstract not provided.

Z facility diagnostic system for high energy density physics at Sandia National Laboratories

Leeper, Ramon J.; Deeney, Christopher D.; Dunham, Gregory S.; Fehl, David L.; Franklin, James K.; Hanson, David L.; Hawn, Rona E.; Hall, Clint A.; Hurst, Michael J.; Jinzo, Tanya D.; Jobe, Daniel O.; Joseph, Nathan R.; Knudson, Marcus D.; Lake, Patrick W.; Lazier, Steven E.; Lucas, J.; McGurn, John S.; Manicke, Matthew P.; Mock, Raymond M.; Moore, T.C.; Nash, Thomas J.; Bailey, James E.; Nelson, Alan J.; Nielsen, D.S.; Olson, Richard E.; Porter, John L.; Pyle, John H.; Rochau, G.A.; Ruggles, Larry R.; Ruiz, Carlos L.; Sanford, Thomas W.; Seamen, Johann J.; Bennett, Guy R.; Simpson, Walter W.; Sinars, Daniel S.; Speas, Christopher S.; Stygar, William A.; Torres, Jose A.; Wenger, D.F.; Carlson, Alan L.; Chandler, Gordon A.; Cooper, Gary W.; Cuneo, M.E.

Abstract not provided.

Z-pinch current-scaling experiments at 10[7] amps

Proposed for publication in Physical Review E.

Stygar, William A.; Matzen, M.K.; Mazarakis, Michael G.; McDaniel, Dillon H.; McGurn, John S.; Mckenney, John M.; Mix, L.P.; Muron, David J.; Porter, John L.; Ramirez, Juan J.; Ruggles, Larry R.; Seamen, Johann F.; Simpson, Walter W.; Speas, Christopher S.; Spielman, Rick B.; Struve, Kenneth W.; Torres, Jose A.; Vesey, Roger A.; Wagoner, Tim C.; Gilliland, Terrance L.; Bennett, Guy R.; Ives, Harry C.; Jobe, Daniel O.; Lazier, Steven E.; Mills, Jerry A.; Mulville, Thomas D.; Pyle, John H.; Romero, Tobias M.; Serrano, Jason D.; Smelser, Ruth S.; Fehl, David L.; Cuneo, M.E.; Bailey, James E.; Bliss, David E.; Chandler, Gordon A.; Leeper, Ramon J.

Abstract not provided.

Dynamics of a Z Pinch X Ray Source for Heating ICF Relevant Hohlraums to 120-160eV

Physics of Plasmas

Sanford, Thomas W.; Olson, Richard E.; Mock, Raymond M.; Chandler, Gordon A.; Leeper, Ramon J.; Nash, Thomas J.; Ruggles, Larry R.; Simpson, Walter W.; Struve, Kenneth W.

A z-pinch radiation source has been developed that generates 60 {+-} 20 KJ of x-rays with a peak power of 13 {+-} 4 TW through a 4-mm diameter axial aperture on the Z facility. The source has heated NIF (National Ignition Facility)-scale (6-mm diameter by 7-mm high) hohlraums to 122 {+-} 6 eV and reduced-scale (4-mm diameter by 4-mm high) hohlraums to 155 {+-} 8 eV -- providing environments suitable for indirect-drive ICF (Inertial Confinement Fusion) studies. Eulerian-RMHC (radiation-hydrodynamics code) simulations that take into account the development of the Rayleigh-Taylor instability in the r-z plane provide integrated calculations of the implosion, x-ray generation, and hohlraum heating, as well as estimates of wall motion and plasma fill within the hohlraums. Lagrangian-RMHC simulations suggest that the addition of a 6 mg/cm{sup 3} CH{sub 2} fill in the reduced-scale hohlraum decreases hohlraum inner-wall velocity by {approximately}40% with only a 3--5% decrease in peak temperature, in agreement with measurements.

More Details
12 Results
12 Results