Publications

21 Results

Search results

Jump to search filters

30 CM horizontal drop of a surrogate 17x17 pwr fuel assembly

American Society of Mechanical Engineers, Pressure Vessels and Piping Division (Publication) PVP

Kalinina, Elena A.; Ammerman, Douglas J.; Grey, Carissa A.; Flores, Gregg J.; Lujan, Lucas A.; Saltzstein, Sylvia J.; Michel, Danielle M.

The 30 cm drop is the remaining NRC normal conditions of transport (NCT) regulatory requirement (10 CFR 71.71) for which there are no data on the response of spent fuel. While obtaining data on the spent fuel is not a direct requirement, it allows for quantifying the risk of fuel breakage resulting from a cask drop from a height of 30 cm or less. Because a full-scale cask and impact limiters are very expensive, 3 consecutive drop tests were conducted to obtain strains on a full-scale surrogate 17x17 PWR assembly. The first step was a 30 cm drop of a 1/3 scale cask loaded with dummy assemblies. The second step was a 30 cm drop test of a full-scale dummy assembly. The third step was a 30 cm drop of a full-scale surrogate assembly. The results of this final test are presented in this paper. The test was conducted in May 2020. The acceleration pulses on the surrogate assembly were in good agreement with the expected pulses derived from steps 1 and 2. This confirmed that during the 30 cm drop the surrogate assembly experienced the same conditions as it would have if it had been dropped in a full-scale cask with impact limiters. The surrogate assembly was instrumented with 27 strain gauges. Pressure paper was inserted between the rods within the two long and two short spacer grid spans in order to register the pressure in case of rod-to-rod contact. The maximum observed peak strain on the surrogate assembly was 1,724 microstrain at the bottom end of the assembly. The pressure paper sheets from the two short spans were blank. The pressure paper sheets from the two long spans, except a few middle ones, showed marks indicating rod-to-rod contact. The maximum estimated contact pressure was 4,100 psi. The longitudinal bending stress corresponding to the maximum observed strain value (calculated from the stress-strain curve for low burnup cladding) was 22,230 psi. Both values are significantly below the yield strength of the cladding. The major conclusion is that the fuel rods will maintain their integrity following a 30 cm drop inside of a transportation cask.

More Details

Surrogate Assembly 30 cm Drop Test

Kalinina, Elena A.; Ammerman, Douglas J.; Grey, Carissa A.; Flores, Gregg J.; Lujan, Lucas A.; Saltzstein, Sylvia J.; Michel, Danielle M.

The 30 cm drop is the remaining NRC normal conditions of transport (NCT) regulatory requirement (10 CFR 71.71) for which there are no data on the actual surrogate fuel. While obtaining data on the actual fuel is not a direct requirement, it provides definitive information which aids in quantifying the risk of fuel breakage resulting from a cask drop from a height of 30 cm or less. The 30 cm drop test with the full-scale surrogate assembly conducted in May 2020 was the last step needed for quantifying the strains on the surrogate assembly rods under NCT. The full-scale surrogate assembly used in the 2020 30 cm drop test was built using a new 17x17 Pressurized Water Reactor (PWR) Westinghouse skeleton filled with the copper rods and 3 zircaloy rods from the full-scale surrogate assembly used in the Multi-Modal Transportation Test (MMTT). Felt pads were attached to the surrogate assembly bottom prior to the 30 cm drop to adequately represent the effects of the impact limiters and the cask. Note that felt "programming material" has been used extensively in past drop tests and is known to be a good material for programming a desired shock pulse. The felt pad configuration was determined during a previous series of tests reported in. The acceleration pulses observed on the surrogate assembly during the test were in good agreement with the expected pulses. This confirmed that during the 30 cm drop the surrogate assembly experienced the same conditions as it would if it was dropped in the cask with the impact limiters.

More Details

30 cm Drop Tests

Kalinina, Elena A.; Ammerman, Douglas J.; Grey, Carissa A.; Arviso, Michael A.; Wright, Catherine W.; Lujan, Lucas A.; Flores, Gregg J.; Saltzstein, Sylvia J.

The data from the multi-modal transportation test conducted in 2017 demonstrated that the inputs from the shock events during all transport modes (truck, rail, and ship) were amplified from the cask to the spent commercial nuclear fuel surrogate assemblies. These data do not support common assumption that the cask content experiences the same accelerations as the cask itself. This was one of the motivations for conducting 30 cm drop tests. The goal of the 30 cm drop test is to measure accelerations and strains on the surrogate spent nuclear fuel assembly and to determine whether the fuel rods can maintain their integrity inside a transportation cask when dropped from a height of 30 cm. The 30 cm drop is the remaining NRC normal conditions of transportation regulatory requirement (10 CFR 71.71) for which there are no data on the actual surrogate fuel. Because the full-scale cask and impact limiters were not available (and their cost was prohibitive), it was proposed to achieve this goal by conducting three separate tests. This report describes the first two tests — the 30 cm drop test of the 1/3 scale cask (conducted in December 2018) and the 30 cm drop of the full-scale dummy assembly (conducted in June 2019). The dummy assembly represents the mass of a real spent nuclear fuel assembly. The third test (to be conducted in the spring of 2020) will be the 30 cm drop of the full-scale surrogate assembly. The surrogate assembly represents a real full-scale assembly in physical, material, and mechanical characteristics, as well as in mass.

More Details

Shaker Table Test

Kalinina, Elena A.; Wright, Adam J.; Ammerman, Douglas J.; Grey, Carissa A.; Arviso, Michael A.

This report describes the Shaker Table Test conducted on September 12, 2018, at the Dynamic Certification Laboratories (DCL) in Sparks, Nevada. This report satisfies Milestone M3SF-19SN010202021 Shaker Table Test, Sandia National Laboratories (SNL) Work Package (Parent WBS # 1.08.01.02.02; Work Package #SF-19SN01020202). The Shaker Table Test is related to the Multi-Modal Transportation Test (MMTT) conducted in 2017. During the MMTT, accelerations and strains were measured on the transportation platform, ENsa UNiversal (ENUN) 32P dual-purpose rail cask, cradle, basket, and three surrogate 17x17 pressurized water reactor (PWR) assemblies (one from SNL, one from Spain and one from Korea).

More Details

Rail-Cask Tests: Normal-Conditionsof- Transport Tests of Surrogate PWR Fuel Assemblies in an ENSA ENUN 32P Cask

McConnell, Paul E.; Ross, Steven; Grey, Carissa A.; Uncapher, William L.; Arviso, Michael A.; Garmendia, Rafael; Fernandez Perez, Ismael; Palacio, Alejandro; Calleja, Guillermo; Garrido, David; Rodriguez Casas, Ana; Gonzalez Garcia, Luis; Chilton, Lyman W.; Ammerman, Douglas J.; Walz, Jacob W.; Gershon, Sabina G.; Saltzstein, Sylvia J.; Sorenson, Ken; Klymyshyn, Nicholas; Hanson, Brady; Pena, Ruben; Walker, Russell

This report describes tests conducted using a full-size rail cask, the ENSA ENUN 32P, involving handling of the cask and transport of the cask via truck, ships, and rail. The purpose of the tests was to measure strains and accelerations on surrogate pressurized water reactor fuel rods when the fuel assemblies were subjected to Normal Conditions of Transport within the rail cask. In addition, accelerations were measured on the transport platform, the cask cradle, the cask, and the basket within the cask holding the assemblies. These tests were an international collaboration that included Equipos Nucleares S.A., Sandia National Laboratories, Pacific Northwest National Laboratory, Coordinadora Internacional de Cargas S.A., the Transportation Technology Center, Inc., the Korea Radioactive Waste Agency, and the Korea Atomic Energy Research Institute. All test results in this report are PRELIMINARY – complete analyses of test data will be completed and reported in FY18. However, preliminarily: The strains were exceedingly low on the surrogate fuel rods during the rail-cask tests for all the transport and handling modes. The test results provide a compelling technical basis for the safe transport of spent fuel.

More Details

Surrogate fuel assembly multi-axis shaker tests to simulate normal conditions of rail and truck transport

Mcconnell, Paul E.; Koenig, Greg J.; Uncapher, William L.; Grey, Carissa A.; Engelhardt, Charles; Saltzstein, Sylvia J.; Sorenson, Ken B.

This report describes the third set of tests (the “DCLa shaker tests”) of an instrumented surrogate PWR fuel assembly. The purpose of this set of tests was to measure strains and accelerations on Zircaloy-4 fuel rods when the PWR assembly was subjected to rail and truck loadings simulating normal conditions of transport when affixed to a multi-axis shaker. This is the first set of tests of the assembly simulating rail normal conditions of transport.

More Details
21 Results