Publications

Results 98001–98025 of 100,993

Search results

Jump to search filters

Text for Mechanical and bulk properties in support of ESF design issues

Price, Ronald H.

An intensive laboratory investigation is being performed to determine the mechanical properties of tuffs for the Yucca Mountain Site Characterization Project (YMP). Most recently, experiments are being performed on tuff samples from a series of drill holes along the proposed alignment of the Exploratory Study Facilities (ESF) north ramp. Unconfined compression and indirect tension experiments are being performed and the results are being analyzed with the help of bulk property information. The results on samples from five of the drill holes are presented here. In general, the properties vary widely, but are highly dependent on the sample porosity.

More Details

Boundary conditions for fluid equations with flux sources and sinks

Riley, Merle E.

I use a piece-wise linear approximation to the directed flux expressions for a flowing Maxwellian fluid to write down boundary conditions for the fluid description of a multicomponent plasma. These boundary conditions are sufficiently robust to treat particle reflection, surface reactions leading to secondary production, diffusion, and field-induced drift of charged species.

More Details

Spectroscopic database for multispectral UV laser remote sensing measurements

Tisone, G.C.; Hargis Jr., P.J.; Clark, B.; Wakefield-Reyes, C.

The optimization of UV laser remote sensing systems and the interpretation of the return signals from these systems require detailed absorption and fluorescence spectra for the species of interest. Multispectral fluorescence techniques additionally require a database of dispersed UV fluorescence excitation spectra. Excitation wavelengths between 250 and 400 nm and fluorescence wavelengths in the 200 to 700 nm range are of interest.

More Details

Integrated UV fluorescence/DIAL model

Page, Karen J.

Current SNL CALIOPE modeling efforts have produced an initial model that addresses DIAL issues of wavelength, hardware design parameters, range evaluation, etc. Although this model is producing valuable results and will be used to support the planning and evaluations necessary for the first ground field experiment, it is expected to have limitations with the complex science issues that affect the CALIOPE program. In particular, the multi-dimensional effects of atmospheric turbulence, plume dynamics, speckle, etc., may be significant issues and must be evaluated in detail as the program moves to the detection of liquids and solids, longer ranges, and elevated platform environments. The goal of the integrated UV fluorescence/DIAL modeling effort is to build upon the knowledge obtained in developing and exercising the initial model to adequately support the future activities of this program. This paper will address the development of the integrated UV model, issues and limiting assumptions that may be needed in order to address the-complex phenomena involved, limits of expected performance, and the potential use of this model.

More Details

Infrared sensor for CVD deposition of dielectric films

Haaland, David M.

Infrared emission (IRE) spectra were obtained from two borophosphosilicate glass (BPSG) thin-film sample sets. The first set consisted of 21 films deposited on undoped silicon wafers, and the second set consisted of 9 films deposited on patterned and doped (product) wafers. The IRE data were empirically modeled using partial least-squares calibration to simultaneously quantify four BPSG thin-film properties. The standard errors of the determinations when modeling the 21 monitor wafers were

More Details

Low cost Image Transmission System

Skogmo, D.

Throughout the Department of Energy (DOE) complex, sites protect themselves with intrusion detection systems. Some of these systems have sensors in remote areas. These sensors frequently alarm -- not because they have detected a terrorist skulking around the area, but because they have detected a horse, or a dog, or a bush moving in the breeze. Even though the local security force is 99% sure there is no real threat, they must assess each of these nuisance or false alarms. Generally, the procedure consists of dispatching an inspector to drive to the area and make an assessment. This is expensive in terms of manpower and the assessment is not timely. Often, by the time the inspector arrives, the cause of the alarm has vanished. A television camera placed to view the area protected by the sensor could be used to help in this assessment, but this requires the installation of high-quality cable, optical fiber, or a microwave link. Further, to be of use at the present time, the site must have had the foresight to have installed these facilities in the past and have them ready for use now. What is needed is a device to place between the television camera and a modem connecting to a low-bandwidth channel such as radio or a telephone line. This paper discusses the development of such a device: an Image Transmission System, or ITS.

More Details

Chemical recognition software

Wagner, John S.

We have developed a capability to make real time concentration measurements of individual chemicals in a complex mixture using a multispectral laser remote sensing system. Our chemical recognition and analysis software consists of three parts: (1) a rigorous multivariate analysis package for quantitative concentration and uncertainty estimates, (2) a genetic optimizer which customizes and tailors the multivariate algorithm for a particular application, and (3) an intelligent neural net chemical filter which pre-selects from the chemical database to find the appropriate candidate chemicals for quantitative analyses by the multivariate algorithms, as well as providing a quick-look concentration estimate and consistency check. Detailed simulations using both laboratory fluorescence data and computer synthesized spectra indicate that our software can make accurate concentration estimates from complex multicomponent mixtures, even when the mixture is noisy and contaminated with unknowns.

More Details

An overview of the mixed waste landfill integrated demonstration

Williams, Cecelia V.

Prior to May 1992, field demonstrations of characterization technologies were performed at an uncontaminated site near the Chemical Waste Landfill. In mid-1992 through summer 1993, both non-intrusive and intrusive characterization techniques were demonstrated at the Chemical Waste Landfill. Subsurface and dry barrier demonstrations were started in summer 1993 and will continue into 1995. Future plans include demonstrations of innovative drilling, characterization and long-term monitoring, and remediation techniques. Demonstrations were also scheduled in summer 1993 at the Kirtland Air Force HSWA site and will continue in 1994. The first phase of the Thermal Enhanced Vapor Extraction System (TEVES) project occurred in April 1992 when two holes were drilled and vapor extraction wells were installed at the Chemical Waste Landfill. Obtaining the engineering design and environmental permits necessary to implement this field demonstration will take until early 1994. Field demonstration of the vapor extraction system will occur in 1994.

More Details

CALIOPE UV laser remote sensing data acquisition and control subsystem

Eyer, H.H.

This paper will discuss the UV Laser Remote Sensing Data Acquisition and Control Subsystem being developed by Sandia National Laboratories in support of the CALIOPE program. Details include the control of active system elements including the laser and beam steering mirror, passive system elements including detectors and signal processing instrumentation, and the acquisition and transfer of data for archival and evaluation by the multivariate analysis algorithm. Using the LabVIEW design philosophy developed for laboratory testing as a baseline, this evolving subsystem will initially support the UV fluorescence calibration and background data collections planned at SNL and the October 1994 Ground Field Experiment at the Nevada Test Site. The subsystem will then be upgraded to support an integrated DIAL/fluorescence capability for the April 1995 Ground Field Experiment and the October 1995 Elevated Platform Field Experiment.

More Details

Using Pro/ENGINEER`s{reg_sign} interface module

Schulze, J.

When the ACCORD Process introduced Pro/ENGINEER to Sandians several years ago, a new process for design/definition was implemented. Prior to ACCORD, engineers and draftsmen worked in the 2-D mode with a program caned ANVIL{reg_sign}, which had limited capabilities. Although the transition from 2-D modeling to 3-D modeling met with some resistance, most engineers have embraced this new concept with enthusiasm They are now able to work in the 3-D mode and at increased levels of productivity with appropriate time savings never achieved before. One area that Pro/ENGINEER is noted for that this report will concentrate on, is the powerful interface module with its wide selection of transfer file configurations. This allows the engineer to create parts or assemblies and transfer them to many different second party software packages whose vendors can provide the capability for stress analysis, rapid prototypes, virtual reality environments, or many other forms of advanced manufacturing modes of communication. The ACCORD Program has at its core, the Pro/ENGINEER program from Parametric Technology Inc. Included in the ACCORD program, are several supporting programs from other vendors to make this cooperation between software packages a reality. It is possible to create parts in Pro/ENG transfer those parts to another package that has the capability to analyze the parts for deficiencies, then optimize those parts, and allow for changes to be made. Also included in this report, are other packages closely tied to Pro/ENGINEER, but not necessarily supported under the ACCORD program. Some of these packages allow you to create very impressive video productions, or allow you to meander through a virtual reality scenario. All of these new software packages will give you a new perspective on performance. This report will show how some of these interfaces work, and how you can improve your productivity if you utilize the ACCORD program as it is implemented here at Sandia.

More Details

Preradiation studies for non-thermal Z-pinch wire load experiments on Saturn

Sanford, Thomas W.L.

The implosion dynamics of compact wire arrays on Saturn are explored as a function of wire mass m, wire length {ell}, wire radii R, and radial power-flow feed geometry using the ZORK code. Electron losses and the likelihood of arcing in the radial feed adjacent the wire load are analyzed using the TWOQUICK and CYLTRAN codes. The physical characteristics of the implosion and subsequent thermal radiation production are estimated using the LASNEX code in one dimension. These analyses show that compact tungsten wire arrays with parameters suggested by D. Mosher and with a 21-nH vacuum feed geometry satisfy the empirical scaling criterion I/(M/{ell}) {approximately} 2 MA/(mg/cm) of Mosher for optimizing non-thermal radiation from z pinches, generate low electron losses in the radial feeds, and generate electric fields at the insulator stack below the Charlie Martin flashover limit thereby permitting full power to be delivered to the load. Under such conditions, peak currents of {approximately}5 MA can be delivered to wire loads {approximately}20 ns before the driving voltage reverses at the insulator stack, potentially allowing the m = 0 instability to develop with the subsequent emission of non-thermal radiation as predicted by the Mosher model.

More Details

Resonator/oscillator response to liquid loading

Martin, Steve W.

A thickness-shear mode (TSM) resonator typically consists of a thin disk of AT-cut quartz with circular electrodes patterned on both sides. When connected to appropriate circuitry, the quartz crystal resonates at a frequency determined by the crystal thickness. Originally used to measure metal deposition in vacuum, the device has recently been used for measurements in liquid. Since the mass sensitivity of the resonator is nearly the same in liquids as in air or vacuum, the device can be used as a sensitive solution-phase microbalance. In addition, the sensitivity of the TSM resonator to contacting fluid properties enables it to function as a monitor for these properties. Under liquid loading, the change in frequency of the resonator/oscillator combination differs from the change in resonant frequency of the device. Either of these changes can be determined from an appropriate application of an equivalent-circuit model that describes the electrical characteristics of the liquid-loaded resonator.

More Details

Basic mechanisms of radiation effects in the natural space radiation environment

Schwank, James R.

Four general topics are covered in respect to the natural space radiation environment: (1) particles trapped by the earth`s magnetic field, (2) cosmic rays, (3) radiation environment inside a spacecraft, (4) laboratory radiation sources. The interaction of radiation with materials is described by ionization effects and displacement effects. Total-dose effects on MOS devices is discussed with respect to: measurement techniques, electron-hole yield, hole transport, oxide traps, interface traps, border traps, device properties, case studies and special concerns for commercial devices. Other device types considered for total-dose effects are SOI devices and nitrided oxide devices. Lastly, single event phenomena are discussed with respect to charge collection mechanisms and hard errors. (GHH)

More Details

The use of supercritical carbon dioxide for contaminant removal from solid waste

Adkins, Carol L.J.

Supercritical carbon dioxide is being explored as a waste minimization technique for separating oils, greases and solvents from solid waste. The containments are dissolved into the supercritical fluid and precipitated out upon depressurization. The carbon dioxide solvent can then be recycled for continued use. Definitions of the temperature, pressure, flowrate and potential co-solvents are required to establish the optimum conditions for hazardous contaminant removal. Excellent extractive capability for common manufacturing oils, greases, and solvents has been observed in both supercritical and liquid carbon dioxide. Solubility measurements are being used to better understand the extraction process, and to determine if the minimum solubility required by federal regulations is met.

More Details

Applications of molecular modeling to the design and characterization of materials

Carlson, G.A.

A variety of new molecular modeling tools are now available for studying molecular structures and molecular interactions, for building molecular structures from simple components using analytical data, and for studying the relationship of molecular structure to the energy of bonding and non-bonding interactions. These are proving quite valuable in characterizing molecular structures and intermolecular interactions and in designing new molecules. This paper describes the application of molecular modeling techniques to a variety of materials problems, including the probable modecular structures of coals, lignins, and hybrid inorganic-organic-organic systems (silsesquioxanes), the intercalation of small gas molecules in fullerene crystals, the diffusion of gas molecules through membranes, and the design, structure and function of biomimetic and nanocluster catalysts.

More Details

Preliminary DIAL model

Gentry, S.M.

A unique end-to-end LIDAR sensor model has been developed supporting the concept development stage of the CALIOPE UV DIAL and UV laser-induced-fluorescence (LIF) efforts. The model focuses on preserving the temporal and spectral nature of signals as they pass through the atmosphere, are collected by the optics, detected by the sensor, and processed by the sensor electronics and algorithms. This is done by developing accurate component sub-models with realistic inputs and outputs, as well as internal noise sources and operating parameters. These sub-models are then configured using data-flow diagrams to operate together to reflect the performance of the entire DIAL system. This modeling philosophy allows the developer to have a realistic indication of the nature of signals throughout the system and to design components and processing in a realistic environment. Current component models include atmospheric absorption and scattering losses, plume absorption and scattering losses, background, telescope and optical filter models, PMT (photomultiplier tube) with realistic noise sources, amplifier operation and noise, A/D converter operation, noise and distortion, pulse averaging, and DIAL computation. Preliminary results of the model will be presented indicating the expected model operation depicting the October field test at the NTS spill test facility. Indications will be given concerning near-term upgrades to the model.

More Details

The Utility-Scale Joint-Venture Program

Gallup, Donald R.

The Department of Energy`s Utility-Scale Joint-Venture (USJV) Program was developed to help industry commercialize dish/engine electric systems. Sandia National Laboratories developed this program and has placed two contracts, one with Science Applications International Corporation`s Energy Projects Division and one with the Cummins Power Generation Company. In this paper we present the designs for the two dish/Stirling systems that are being developed through the USJV Program.

More Details

MAGENCO: A map generalization controller for Arc/Info

Ganter, John H.

The Arc/Info GENERALIZE command implements the Douglas-Peucker algorithm, a well-regarded approach that preserves line ``character`` while reducing the number of points according to a tolerance parameter supplied by the user. The authors have developed an Arc Macro Language (AML) interface called MAGENCO that allows the user to browse workspaces, select a coverage, extract a sample from this coverage, then apply various tolerances to the sample. The results are shown in multiple display windows that are arranged around the original sample for quick visual comparison. The user may then return to the whole coverage and apply the chosen tolerance. They analyze the ergonomics of line simplification, explain the design (which includes an animated demonstration of the Douglas-Peucker algorithm), and discuss key points of the MAGENCO implementation.

More Details

Comparison of the KAMELEON fire model to large-scale open pool fire data

Nicolette, Vernon F.

A comparison of the KAMELEON Fire model to large-scale open pool fire experimental data is presented. The model was used to calculate large-scale JP-4 pool fires with and without wind, and with and without large objects in the fire. The effect of wind and large objects on the fire environment is clearly seen. For the pool fire calculations without any object in the fire, excellent agreement is seen in the location of the oxygen-starved region near the pool center. Calculated flame temperatures are about 200--300 K higher than measured. This results in higher heat fluxes back to the fuel pool and higher fuel evaporation rates (by a factor of 2). Fuel concentrations at lower elevations and peak soot concentrations are in good agreement with data. For pool fire calculations with objects, similar trends in the fire environment are observed. Excellent agreement is seen in the distribution of the heat flux around a cylindrical calorimeter in a rectangular pool with wind effects. The magnitude of the calculated heat flux to the object is high by a factor of 2 relative to the test data, due to the higher temperatures calculated. For the case of a large flat plate adjacent to a circular pool, excellent qualitative agreement is seen in the predicted and measured flame shapes as a function of wind.

More Details

Resonator response to Non-Newtonian fluids

Martin, Steve W.

The thickness-shear mode (TSM) resonator typically consists of a thin disk of AT-cut quartz with circular electrodes patterned on both sides. An RF voltage applied between these electrodes excites a shear mode mechanical resonance when the excitation frequency matches the crystal resonant frequency. When the TSM resonator is operated in contact with a liquid, the shear motion of the surface generates motion in the contacting liquid. The liquid velocity field, v{sub x}(y), can be determined by solving the one-dimensional Navier-Stokes equation. Newtonian fluids cause an equal increase in resonator motional resistance and reactance, R{sub 2}{sup (N)} = X{sub 2}{sup (N)}, with the response depending only on the liquid density-viscosity product ({rho}{eta}). Non-Newtonian fluids, as illustrated by the simple example of a Maxwell fluid, can cause unequal increases in motional resistance and reactance. For the Maxwell fluid, R{sub 2}{sup (M)} > X{sub 2}{sup (M)}, with relaxation time {tau} proportional to the difference between R{sub 2}{sup (M)}and X{sub 2}{sup (M)}. Early results indicate that a TSM resonator can be used to extract properties of non-Newtonian fluids.

More Details

Determination of the shear modulus in self-assembled monolayers using quartz resonators

Schneider, T.W.; Martin, S.J.; Frye, G.C.

This work examined self-assembled monolayers (SAMs) of n-alkane thiols using quartz resonators to determine the shear storage and loss moduli. Network analyzer measurements of electrical admittance at fundamental and corresponding harmonic values are fit to an equivalent circuit model. Shear modulus depends on frequency; the modulus values are three orders of magnitude lower than expected for a liquid or elastomeric polymer, more like those of a dense gas or supercritical fluid. A density of around 0.45 g/cm{sup 3} is calculated for a dodecane thiol SAM; this is roughly half of the bulk density. In conclusion, quartz resonators can be used to inertially deform SAMs.

More Details

How clean is clean: Non-destructive/direct methods of flux, residue detection

Stallard, Brian R.

The feasibility of three different non-destructive and direct methods of evaluating PCB (printed circuit boards) cleanliness was demonstrated. The detection limits associated with each method were established. In addition, the pros and cons of these methods as routine quality control inspection tools were discussed. OSEE (Optically Stimulated Electron Emission) was demonstrated to be a sensitive technique for detection of low levels of flux residues on insulating substances. However, future work including development of rugged OSEE instrumentation will determine whether the PCB industry can accept this technique in a production environment. FTIR (Fourier Transform Infrared) microscopy is a well established technique with well known characteristics. The inability of FTIR to discriminate an organic contaminant from an organic substrate limits its usefulness as a PCB line inspection tool, but it will still remain a technique for the QC/QA laboratory. One advantage of FTIR over the other two techniques described here is its ability to identify the chemical nature of the residue, which is important in Failure Mode Analysis. Optical imaging using sophisticated pattern recognition algorithms was found to be limited to high concentrations of residue. Further work on improved sensor techniques is necessary.

More Details

The effects of spatial location of defect states on the switching characteristics of amorphous and polycrystalline silicon thin film transistors: A numerical simulation using AMPS 2-D

Smith, J.; Fonash, S.; Kalkan, A.

We demonstrate a two-dimensional device simulator for MOSFET structures that incorporates models for defect distributions and show predicted effects on device switching performance for various spatial distributions of defects in amorphous and polycrystalline silicon.

More Details

Description of a high temperature quenching furnace for the study of the directional solidification of nickel-base superalloys

Schmale, David T.

A high temperature resistance furnace has been modified for the study of directional solidification of nickel-base superalloys such as alloys 718 and 625. The furnace will be used to study segregation and solidification phenomena that occur in consumable-electrode melting processes such as vacuum arc remelting and electro-slag remelting. The system consists of a water cooled high temperature furnace (maximum temperature {approximately}2900 C), roughing vacuum,system, cooling system, cooled hearth, molten metal quenching bath, and a mechanism to lower the hearth from the furnace into the molten metal bath. The lowering mechanism is actuated by a digital stopping motor with a programmable controller. The specimen (1.9 cm dia {times} 14 cm long) is melted and contained within an alumina tube (2.54 cm dia {times} 15.24 cm long) which is seated on a copper hearth cooled with {approximately}13 C water. Directional solidification can then be accomplished by decreasing the furnace temperature while holding the specimen in position, maintaining the temperature gradient in the furnace and lowering the specimen at a controlled rate or a combination of both. At any point the specimen can be lowered rapidly into the 70 C molten metal bath to quench the specimen, preserve the solidification structure, and minimize solid state diffusion, enhancing the ability to study the localized solidification conditions.

More Details

ATM-test: A workstation-based software suite for testing asynchronous transfer mode (ATM) networks

Tarman, Thomas D.

The design of a software package that provides a variety of Asynchronous Transfer Mode (ATM) test functions is presented here. These functions include cell capture, protocol decode for Transmission Control Protocol/Internet Protocol (TCP/IP) services, removal of cells (to support testing of an ATM system under cell loss conditions), and echo functions. This package is currently written to operate on the Sun Microsystems SPARCstation 10/SunOS 4.1.3 environment with a Fore Systems SBA-100 Sbus ATM adapter (140 Mbit/s TAXI interface), and the DEC 5000/240 running ULTRIX 4.2A with a Fore Systems TCA-100 TurboChannel adapter. Application scenarios and performance measurements of this software package on these host environments are presented here.

More Details
Results 98001–98025 of 100,993
Results 98001–98025 of 100,993
Top