Jump to search filtersA technology acquisition strategy for the security of water distribution networks
This slide presentation outlines information on a technology acquisition strategy for the security of water distribution networks. The Department of Homeland Security (DHS) has tasked a multi-laboratory team to evaluate current and future needs to protect the nation's water distribution infrastructure by supporting an objective evaluation of current and new technologies. The primary deliverables from this Operational Technology Demonstration (OTD) are the following: establishment of an advisory board for review and approval of testing protocols, technology acquisition processes and recommendations for technology test and evaluation in laboratory and field settings; development of a technology acquisition process; creation of laboratory and field testing and evaluation capability; and, testing of candidate technologies for insertion into a water early warning system. The initial phase of this study involves the development of two separate but complementary strategies to be reviewed by the advisory board: a technology acquisition strategy; and, a technology evaluation strategy. Lawrence Livermore National Laboratory and Sandia National Laboratories are tasked with the first strategy, while Los Alamos, Pacific Northwest, and Oak Ridge National Laboratories are tasked with the second strategy. The first goal of the acquisition strategy is the development of a technology survey process that includes a review of current test programs and development of a method to solicit and select existing and emerging sensor technologies for evaluation and testing. The second goal is to implement the acquisition strategy to provide a set of recommendations for candidate technologies for laboratory and field testing.
Rapid inactivation and verification of High consequence viral agents to agriculture
DF-200 : an enhanced Sandia decontamination formulation for neutralization of CBW agents and toxic industrial chemicals
Abstract not provided.
The role of early warning systems in water security
Abstract not provided.
Design and Testing of a Micro Thermal Conductivity Detector (TCD) System
This work describes the design, simulation, fabrication and characterization of a microfabricated thermal conductivity detector to be used as an extension of the {micro}ChemLab{trademark}. The device geometry was optimized by simulating the heat transfer in the device, utilizing a boundary element algorithm. In particular it is shown that within microfabrication constraints, a micro-TCD optimized for sensitivity can be readily calculated. Two flow patterns were proposed and were subsequently fabricated into nine-promising geometries. The microfabricated detector consists of a slender metal film, supported by a suspended thin dielectric film over a pyramidal or trapezoidal silicon channel. It was demonstrated that the perpendicular flow, where the gas directly impinges on the membrane, creates a device that is 3 times more sensitive than the parallel flow, where the gas passed over the membrane. This resulted in validation of the functionality of a microfabricated TCD as a trace-level detector, utilizing low power. the detector shows a consistent linear response to concentration and they are easily able to detect 100-ppm levels of CO in He. Comparison of noise levels for this analysis indicates that sub part per million (ppm) levels are achievable with the selection of the right set of conditions for the detector to operate under. This detector was originally proposed as part of a high-speed detection system for the petrochemical gas industry. This system was to be utilized as a process monitor to detect reactor ''upset'' conditions before a run away condition could occur (faster than current full-scale monitoring systems were able to achieve). Further outlining of requirements indicated that the detection levels likely achievable with a TCD detector would not be sufficient to meet the process condition needs. Therefore the designed and fabricated detector was integrated into a detection system to showcase some technologies that could further the development of components for the current gas phase {micro}ChemLab as well as future modifications for process monitoring work such as: pressurized connections, gas sampling procedures, and packed columns. Component integration of a microfabricated planar pre-concentrator, gas-chromatograph column and TCD in the separation/detection of hydrocarbons, such as benzene, toluene and xylene (BTX) was also demonstrated with this system.
Field analytical technology verification: the ETV site characterization program
Proceedings of the Air & Waste Management Association's Annual Meeting & Exhibition
The EPA Environmental Technology Verification (ETV) Site Characterization Pilot is a joint effort between EPA and DOE with the objective of accelerating the acceptance of technologies that reduce the cost and increase the speed of environmental clean-up and monitoring. To date, several technology verifications have already been completed. Typical results from completed field demonstrations are presented to illustrate the verification process and the importance of the program in providing objective information to aid potential users in making informed choices regarding the efficacy of these technologies for their specific characterization and monitoring problems.
Instrumentation advances in emissions characterization from propellant/explosive combustion
Results from a chamber study to characterize emissions from combustion of selected pure energetic materials are presented in this paper. The study was carried out as a part of a comprehensive air pathways risk assessment for a propellant and explosive manufacturing facility that engages in open burning methods for manufacturing waste disposal. Materials selected for emissions characterization in this study included both aluminized and non-aluminized composite propellant, a double base propellant and a plastic bonded explosive. Combustion tests in a specialized chamber revealed very low emissions for gaseous products of incomplete combustion such as carbon monoxide and nitrogen oxides. Analysis of gaseous and aerosol emission products for a pre-selected target analyte list that included both volatile and semi-volatile organics revealed either low or non-detectable emissions for the four energetic types tested. Hydrogen chloride was detected as a major emission product from propellants containing ammonium perchlorate. Results from this work reveal that about one-half of the chlorine in the original material is released as hydrogen chloride. Based on earlier work, the balance of the chlorine emissions is expected to be in the form of chlorine gas.
Glass bead size and morphology characteristics in support of Crystal Mist field experiments
One of the tasks of the Lethality Group within US Army Space and Strategic Defense Command (USASSDC) is the development of a capability to simulate various missile intercept scenarios using computer codes. Currently under development within USASSDC and its various contractor organizations is a group of codes collected under a master code called PEGEM for Post Event Ground Effects Model. Among the various components of the code are modules which are used to predict atmospheric dispersion and transport of particles or droplets following release at the altitude specified in the missile intercept scenario. The atmospheric transport code takes into account various source term data from the intercept such as: initial cloud size; droplet or particle size distribution; and, total mass of agent released. An ongoing USASSDC experimental program termed Crystal Mist involved release of precision glass beads under various altitude and meteorological conditions to assist in validation and refinement of various codes that are components of PEGEM used to predict particle atmospheric transport and diffusion following a missile intercept. Here, soda-lime glass beads used in the Crystal Mist series of atmospheric transport and diffusion tests were characterized by scanning electron microscopy and automated image processing routines in order to fully define their size distributions and morphology. Four bead size classifications ranging from a median count diameter of 45 to 200 micrometers were found to be approximately spherical and to fall within the supplier`s sizing specifications. Log-normal functions fit to the measured size distributions resulted in geometric standard deviations ranging from 1.08 to 1.12, thereby fulfilling the field trial requirements for a relatively narrow bead size distribution.
Winter season air pollution in El Paso-Ciudad Juarez. A review of air pollution studies in an international airshed
This report summarizes a number of research efforts completed over the past 20 years in the El Paso del Norte region to characterize pollution sources and air quality trends. The El Paso del Norte region encompasses the cities of El Paso, Texas and Ciudad Juarez, Chihuahua and is representative of many US-Mexico border communities that are facing important air quality issues as population growth and industrialization of Mexican border communities continue. Special attention is given to a group of studies carried out under special US Congressional funding and administered by the US Environmental Protection Agency. Many of these studies were fielded within the last several years to develop a better understanding of air pollution sources and trends in this typical border community. Summary findings from a wide range of studies dealing with such issues as the temporal and spatial distribution of pollutants and pollution potential from both stationary and mobile sources in both cities are presented. Particular emphasis is given to a recent study in El Paso-Ciudad Juarez that focussed on winter season PM{sub 10} pollution in El Paso-Ciudad Juarez. Preliminary estimates from this short-term study reveal that biomass combustion products and crustal material are significant components of winter season PM{sub 10} in this international border community.