Publications

Results 101–125 of 148

Search results

Jump to search filters

Accelerating transient simulation of linear reduced order models

Keiter, Eric R.; Mei, Ting M.; Thornquist, Heidi K.

Model order reduction (MOR) techniques have been used to facilitate the analysis of dynamical systems for many years. Although existing model reduction techniques are capable of providing huge speedups in the frequency domain analysis (i.e. AC response) of linear systems, such speedups are often not obtained when performing transient analysis on the systems, particularly when coupled with other circuit components. Reduced system size, which is the ostensible goal of MOR methods, is often insufficient to improve transient simulation speed on realistic circuit problems. It can be shown that making the correct reduced order model (ROM) implementation choices is crucial to the practical application of MOR methods. In this report we investigate methods for accelerating the simulation of circuits containing ROM blocks using the circuit simulator Xyce.

More Details

Xyce parallel electronic simulator : reference guide

Keiter, Eric R.; Warrender, Christina E.; Mei, Ting M.; Russo, Thomas V.; Pawlowski, Roger P.; Schiek, Richard S.; Santarelli, Keith R.; Coffey, Todd S.; Thornquist, Heidi K.

This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide. The Xyce Parallel Electronic Simulator has been written to support, in a rigorous manner, the simulation needs of the Sandia National Laboratories electrical designers. It is targeted specifically to run on large-scale parallel computing platforms but also runs well on a variety of architectures including single processor workstations. It also aims to support a variety of devices and models specific to Sandia needs. This document is intended to complement the Xyce Users Guide. It contains comprehensive, detailed information about a number of topics pertinent to the usage of Xyce. Included in this document is a netlist reference for the input-file commands and elements supported within Xyce; a command line reference, which describes the available command line arguments for Xyce; and quick-references for users of other circuit codes, such as Orcad's PSpice and Sandia's ChileSPICE.

More Details

Xyce parallel electronic simulator : users' guide

Keiter, Eric R.; Warrender, Christina E.; Mei, Ting M.; Russo, Thomas V.; Pawlowski, Roger P.; Schiek, Richard S.; Santarelli, Keith R.; Coffey, Todd S.; Thornquist, Heidi K.

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: (1) Capability to solve extremely large circuit problems by supporting large-scale parallel computing platforms (up to thousands of processors). Note that this includes support for most popular parallel and serial computers; (2) Improved performance for all numerical kernels (e.g., time integrator, nonlinear and linear solvers) through state-of-the-art algorithms and novel techniques. (3) Device models which are specifically tailored to meet Sandia's needs, including some radiation-aware devices (for Sandia users only); and (4) Object-oriented code design and implementation using modern coding practices that ensure that the Xyce Parallel Electronic Simulator will be maintainable and extensible far into the future. Xyce is a parallel code in the most general sense of the phrase - a message passing parallel implementation - which allows it to run efficiently on the widest possible number of computing platforms. These include serial, shared-memory and distributed-memory parallel as well as heterogeneous platforms. Careful attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows. The development of Xyce provides a platform for computational research and development aimed specifically at the needs of the Laboratory. With Xyce, Sandia has an 'in-house' capability with which both new electrical (e.g., device model development) and algorithmic (e.g., faster time-integration methods, parallel solver algorithms) research and development can be performed. As a result, Xyce is a unique electrical simulation capability, designed to meet the unique needs of the laboratory.

More Details

Analytic 1D pn junction diode photocurrent solutions following ionizing radiation and including time-dependent changes in the carrier lifetime

Axness, Carl L.; Keiter, Eric R.

Circuit simulation tools (e.g., SPICE) have become invaluable in the development and design of electronic circuits in radiation environments. These codes are often employed to study the effect of many thousands of devices under transient current conditions. Device-scale simulation tools (e.g., MEDICI) are commonly used in the design of individual semiconductor components, but require computing resources that make their incorporation into a circuit code impossible for large-scale circuits. Analytic solutions to the ambipolar diffusion equation, an approximation to the carrier transport equations, may be used to characterize the transient currents at nodes within a circuit simulator. We present new transient 1D excess carrier density and photocurrent density solutions to the ambipolar diffusion equation for low-level radiation pulses that take into account a finite device geometry, ohmic fields outside the depleted region, and an arbitrary change in the carrier lifetime due to neutron irradiation or other effects. The solutions are specifically evaluated for the case of an abrupt change in the carrier lifetime during or after, a step, square, or piecewise linear radiation pulse. Noting slow convergence of the raw Fourier series for certain parameter sets, we use closed-form formulas for some of the infinite sums to produce 'partial closed-form' solutions for the above three cases. These 'partial closed-form' solutions converge with only a few tens of terms, which enables efficient large-scale circuit simulations.

More Details

A physics-based device model of transient neutron damage in bipolar junction transistors

IEEE Transactions on Nuclear Science

Keiter, Eric R.; Russo, Thomas V.; Hembree, Charles E.; Kambour, Kenneth E.

For the purpose of simulating the effects of neutron radiation damage on bipolar circuit performance, a bipolar junction transistor (BJT) compact model incorporating displacement damage effects and rapid annealing has been developed. A physics-based approach is used to model displacement damage effects, and this modeling approach is implemented as an augmentation to the Gummel-Poon BJT model. The model is presented and implemented in the Xyce circuit simulator, and is shown to agree well with experiments and TCAD simulation, and is shown to be superior to a previous compact modeling approach. © 2010 IEEE.

More Details

Xyce parallel electronic simulator design

Keiter, Eric R.; Russo, Thomas V.; Schiek, Richard S.; Thornquist, Heidi K.; Mei, Ting M.

This document is the Xyce Circuit Simulator developer guide. Xyce has been designed from the 'ground up' to be a SPICE-compatible, distributed memory parallel circuit simulator. While it is in many respects a research code, Xyce is intended to be a production simulator. As such, having software quality engineering (SQE) procedures in place to insure a high level of code quality and robustness are essential. Version control, issue tracking customer support, C++ style guildlines and the Xyce release process are all described. The Xyce Parallel Electronic Simulator has been under development at Sandia since 1999. Historically, Xyce has mostly been funded by ASC, the original focus of Xyce development has primarily been related to circuits for nuclear weapons. However, this has not been the only focus and it is expected that the project will diversify. Like many ASC projects, Xyce is a group development effort, which involves a number of researchers, engineers, scientists, mathmaticians and computer scientists. In addition to diversity of background, it is to be expected on long term projects for there to be a certain amount of staff turnover, as people move on to different projects. As a result, it is very important that the project maintain high software quality standards. The point of this document is to formally document a number of the software quality practices followed by the Xyce team in one place. Also, it is hoped that this document will be a good source of information for new developers.

More Details

New analytic 1D pn junction diode transient photocurrent solutions following ionizing radiation and including time-dependent carrier lifetime degradation from a non-concurrent neutron pulse

Axness, Carl L.; Keiter, Eric R.

Circuit simulation codes, such as SPICE, are invaluable in the development and design of electronic circuits in radiation environments. These codes are often employed to study the effect of many thousands of devices under transient current conditions. Device-scale simulation codes are commonly used in the design of individual semiconductor components, but computational requirements limit their use to small-scale circuits. Analytic solutions to the ambipolar diffusion equation, an approximation to the carrier transport equations, may be used to characterize the transient currents at nodes within a circuit simulator. We present new analytic transient excess carrier density and photocurrent solutions to the ambipolar diffusion equation for 1-D abrupt-junction pn diodes. These solutions incorporate low-level radiation pulses and take into account a finite device geometry, ohmic fields outside the depleted region, and an arbitrary change in the carrier lifetime due to neutron irradiation or other effects. The solutions are specifically evaluated for the case of an abrupt change in the carrier lifetime during or after, a step, square, or piecewise linear radiation pulse. Noting slow convergence of the Fourier series solutions for some parameters sets, we evaluate portions of the solutions using closed-form formulas, which result in a two order of magnitude increase in computational efficiency.

More Details

Xyce parallel electronic simulator

Keiter, Eric R.; Russo, Thomas V.; Schiek, Richard S.; Mei, Ting M.; Thornquist, Heidi K.; Coffey, Todd S.; Santarelli, Keith R.; Pawlowski, Roger P.

This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide.

More Details

Xyce parallel electronic simulator release notes

Keiter, Eric R.; Santarelli, Keith R.; Hoekstra, Robert J.; Russo, Thomas V.; Schiek, Richard S.; Mei, Ting M.; Thornquist, Heidi K.; Pawlowski, Roger P.; Coffey, Todd S.

The Xyce Parallel Electronic Simulator has been written to support, in a rigorous manner, the simulation needs of the Sandia National Laboratories electrical designers. Specific requirements include, among others, the ability to solve extremely large circuit problems by supporting large-scale parallel computing platforms, improved numerical performance and object-oriented code design and implementation. The Xyce release notes describe: Hardware and software requirements New features and enhancements Any defects fixed since the last release Current known defects and defect workarounds For up-to-date information not available at the time these notes were produced, please visit the Xyce web page at http://www.cs.sandia.gov/xyce.

More Details

Parallel algorithm strategies for circuit simulation

Keiter, Eric R.; Thornquist, Heidi K.; Schiek, Richard S.

Circuit simulation tools (e.g., SPICE) have become invaluable in the development and design of electronic circuits. However, they have been pushed to their performance limits in addressing circuit design challenges that come from the technology drivers of smaller feature scales and higher integration. Improving the performance of circuit simulation tools through exploiting new opportunities in widely-available multi-processor architectures is a logical next step. Unfortunately, not all traditional simulation applications are inherently parallel, and quickly adapting mature application codes (even codes designed to parallel applications) to new parallel paradigms can be prohibitively difficult. In general, performance is influenced by many choices: hardware platform, runtime environment, languages and compilers used, algorithm choice and implementation, and more. In this complicated environment, the use of mini-applications small self-contained proxies for real applications is an excellent approach for rapidly exploring the parameter space of all these choices. In this report we present a multi-core performance study of Xyce, a transistor-level circuit simulation tool, and describe the future development of a mini-application for circuit simulation.

More Details

Xyce parallel electronic simulator : users' guide. Version 5.1

Keiter, Eric R.; Mei, Ting M.; Russo, Thomas V.; Pawlowski, Roger P.; Schiek, Richard S.; Santarelli, Keith R.; Coffey, Todd S.; Thornquist, Heidi K.

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: (1) Capability to solve extremely large circuit problems by supporting large-scale parallel computing platforms (up to thousands of processors). Note that this includes support for most popular parallel and serial computers. (2) Improved performance for all numerical kernels (e.g., time integrator, nonlinear and linear solvers) through state-of-the-art algorithms and novel techniques. (3) Device models which are specifically tailored to meet Sandia's needs, including some radiation-aware devices (for Sandia users only). (4) Object-oriented code design and implementation using modern coding practices that ensure that the Xyce Parallel Electronic Simulator will be maintainable and extensible far into the future. Xyce is a parallel code in the most general sense of the phrase - a message passing parallel implementation - which allows it to run efficiently on the widest possible number of computing platforms. These include serial, shared-memory and distributed-memory parallel as well as heterogeneous platforms. Careful attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows. The development of Xyce provides a platform for computational research and development aimed specifically at the needs of the Laboratory. With Xyce, Sandia has an 'in-house' capability with which both new electrical (e.g., device model development) and algorithmic (e.g., faster time-integration methods, parallel solver algorithms) research and development can be performed. As a result, Xyce is a unique electrical simulation capability, designed to meet the unique needs of the laboratory.

More Details
Results 101–125 of 148