This paper describes the hardware changes made to the triggering system of the HERMES III accelerator at Sandia National Laboratories, New Mexico. The HERMES III accelerator is a gamma ray simulator producing 100 kRad dose per shot with a full width half max pulse duration of approximately 25 nanoseconds and averaging six shots per day. For each accelerator test, approximately 400 probe signals are recorded over approximately 65 digitizers. The original digitizer trigger system employed numerous independent legacy signal generators resulting in non-referenceable digitizer time bases. We detail our efforts to reference the digitizer time bases together using a modular and scalable approach with commercial-off-the-shelf components. This upgraded trigger system presently measures a maximum digitizer trigger time spread of less than two nanoseconds across the 65+ digitizers. This document details the hardware changes, provides a summary of the accelerator charging process, presents 'one-line' trigger system diagrams and summarizes the times of interest for a typical HERMES accelerator shot.
This paper describes the software changes made to the data processing and display system for HERMES III accelerator at the Simulation Technology Laboratory (STL) at Sandia National Laboratories, New Mexico. The HERMES III accelerator is a gamma ray simulator producing 100kRad[Si] dose per shot with a full width half max pulse duration of 25 nanoseconds averaging six shots per day. For each accelerator test approximately 400 probe signals are recorded over approximately 65 digitizers. The original data processing system provided the operator a report summarizing the start of probe signal timings for groups of probes located within the power flow conductors. This timing information is indicative of power flow symmetry allowing the operator to make necessary adjustments prior to the next test. The report also provided data overlays concerning laser trigger light output, x-ray diode currents and x-ray source output. Power flow in the HERMES III accelerator is comprised of many circuit paths and detailed current and voltage information within these paths could provide a more thorough understanding of accelerator operation and performance, however this information was either not quickly available to the operators or the display of the data was not optimum. We expanded our data processing abilities to determine the current and voltage amplitudes throughout the power flow conductors and improved the data display abilities so data plots can be presented in a more organized fashion. We detail our efforts creating a software program capable of processing the 400 probe signals together with an organized method for displaying the dozens of current and voltage probes. This process is implemented immediately after all digitizer data has been collected so the operator is provided timing and power flow information shortly after each accelerator shot.
The HERMES III accelerator, which is located at Sandia National Laboratories' Tech Area IV, is the largest pulsed gamma X-ray source in the world. The accelerator is made up of 20 inductive cavities that are charged to 1 MV each by complex pulsed power circuitry. The firing time of the machine components ranges between the microsecond and nanosecond timescales. This results in a variety of electromagnetic frequencies when the accelerator fires. Testing was done to identify the HERMES electromagnetic noise signal and to map it to the various accelerator trigger events. This report will show the measurement methods used to capture the noise spectrum produced from the machine and correlate this noise signature with machine events.
A new laser trigger system (LTS) has been installed on Z that benefits the experimenter with reduced temporal jitter on the x-ray output, the confidence to use command triggers for time sensitive diagnostics and the ability to shape the current pulse at the load. This paper presents work on the pulse shapping aspects othe the new LTS.