Publications Details

Publications / Book

Plenoptic Background Oriented Schlieren Imaging

Munz, Elise D.; Davis, Jenna; Guildenbecher, Daniel R.; Thurow, Brian

Plenoptic background-oriented schlieren is a diagnostictechnique that enables the measure-ment of three-dimensional refractive gradients by a combination of background-oriented schlieren and a plenoptic light field camera. This plenoptic camera is a modification of a traditional camera via the insertion of an array of microlenses between the imaging lens and digital sensor. This allows the collection of both spatial and angular information on the incoming light rays and therefore provides three-dimensional information about the imaged scene. Background-oriented schlieren requires a relatively simple experimental configurationincludingonlyacameraviewing a patterned background through the density field of interest. By using a plenoptic camera to capture background-oriented schlieren images the optical distortion created by density gradients in three dimensions can be measured. This chapter is intended to review critical developments in plenoptic background-oriented schlieren imaging and provide an outlook for future applications of this measurement technique.