Three dimensional optics
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
This report has the following topics: (1) Changing perspectives on nuclear safety and security; (2) Evolving needs in a post-9/11 era; (3) Nuclear Weapons--An attractive terrorist target; (4) The case for increased safety; (5) Evolution of current nuclear weapons safety and security; (6) Integrated surety; (7) The role of safety and security in enabling responsiveness; (8) Advances in surety technologies; and (9) Reevaluating safety.
Sandia's advanced computing resources provide researchers, engineers and analysts with the ability to develop and render highly detailed large-scale models and simulations. To take full advantage of these multi-million data point visualizations, display systems with comparable pixel counts are needed. The Interactive Design Center (IDC) is a second generation visualization theater designed to meet this need. The main display integrates twenty-seven projectors in a 9-wide by 3-high array with a total display resolution of more than 35 million pixels. Six individual SmartBoard displays offer interactive capabilities that include on-screen annotation and touch panel control of the facility's display systems. This report details the design, implementation and operation of this innovative facility.
Existing contraband detection and entry control devices such as metal detectors, X-ray machines, and radiation monitors were investigated for their capability to operate in an automated environment. In addition, a limited number of new devices for detection of explosives, chemicals, and biological agents were investigated for their feasibility for inclusion in future physical security systems. The tables in this document resulted from this investigation, which was part of a conceptual design upgrade for the United States Mints. This summary of commercially available technologies was written to provide a reference for physical security upgrades at other sites.
Proposed for publication in the Journal of Thermal Spray Technology.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Proposed for publication in the IEEE Transactions on Nuclear Science.
Under conditions that were predicted as 'safe' by well-established TCAD packages, radiation hardness can still be significantly degraded by a few lucky arsenic ions reaching the gate oxide during self-aligned CMOS source/drain ion implantation. The most likely explanation is that both oxide traps and interface traps are created when ions penetrate and damage the gate oxide after channeling or traveling along polysilicon grain boundaries during the implantation process.
Proposed for publication in Proceedings of the National Academy of Sciences.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Three-dimensional hybrid simulation of a plasma current-carrying column reveal two different regimes of sausage and kink instability development. In the first regime, with small Hall parameter, development of instabilities leads to the appearance of large-scale axial perturbations and eventually to bending of the plasma column. In the second regime, with a four-times-larger Hall parameter, small-scale perturbations dominate and no bending of the plasma column is observed. Simulation results are compared with laser probing experimental data obtained during wire array implosions on the Zebra pulse power generator at the Nevada Terawatt Facility.
A 1 MV linear transformer driver (LTD), capable of driving a radiographic diode load, has been built and tested. A circuit model of this accelerator has been developed using the BERTHA circuit simulation code. Simulations are compared to data from power-flow experiments utilizing a large area electron-beam diode load. Results show that the simulation model performs well in modeling the baseline operation of the accelerator. In addition, the circuit model has been used to predict several possible fault modes. Simulations of switch prefires, main capacitor failure, vacuum insulator flashover, and core saturation have been used to estimate the probability of inducing further failures and the impact on the load voltage and current.
A 1 MV linear transformer driver (LTD) is being tested with a large area e-beam diode load at Sandia National Laboratories (SNL). The experiments will be utilized to determine the repeatability of the output pulse and the reliability of the components. The 1 MV accelerator is being used to determine the feasibility of designing a 6 MV LTD for radiography experiments. The peak voltage, risetime, and pulse width as well as the cavity timing jitter are analyzed to determine the repeatability of the output pulse.
Graph partitioning is often used for load balancing in parallel computing, but it is known that hypergraph partitioning has several advantages. First, hypergraphs more accurately model communication volume, and second, they are more expressive and can better represent nonsymmetric problems. Hypergraph partitioning is particularly suited to parallel sparse matrix-vector multiplication, a common kernel in scientific computing. We present a parallel software package for hypergraph (and sparse matrix) partitioning developed at Sandia National Labs. The algorithm is a variation on multilevel partitioning. Our parallel implementation is novel in that it uses a two-dimensional data distribution among processors. We present empirical results that show our parallel implementation achieves good speedup on several large problems (up to 33 million nonzeros) with up to 64 processors on a Linux cluster.
Abstract not provided.
Abstract not provided.
A methodology was developed for computing the probability that the sensor dart for the 'Near Real-Time Site Characterization for Assured HDBT Defeat' Grand-Challenge LDRD project will survive deployment over a forested region. The probability can be decomposed into three approximately independent probabilities that account for forest coverage, branch density and the physics of an impact between the dart and a tree branch. The probability that a dart survives an impact with a tree branch was determined from the deflection induced by the impact. If a dart that was deflected so that it impacted the ground at an angle of attack exceeding a user-specified, threshold value, the dart was assumed to not survive the impact with the branch; otherwise it was assumed to have survived. A computer code was developed for calculating dart angle of attack at impact with the ground and a Monte Carlo scheme was used to calculate the probability distribution of a sensor dart surviving an impact with a branch as a function of branch radius, length, and height from the ground. Both an early prototype design and the current dart design were used in these studies. As a general rule of thumb, it we observed that for reasonably generic trees and for a threshold angle of attack of 5{sup o} (which is conservative for dart survival), the probability of reaching the ground with an angle of attack less than the threshold is on the order of 30% for the prototype dart design and 60% for the current dart design, though these numbers should be treated with some caution.
The study described in this report used mathematical modeling to estimate health risks from exposure to depleted uranium (DU) during the 1991 Gulf War for both U.S. troops and nearby Iraqi civilians. The analysis found that the risks of DU-induced leukemia or birth defects are far too small to result in an observable increase in these health effects among exposed veterans or Iraqi civilians. Only a few veterans in vehicles accidentally struck by U.S. DU munitions are predicted to have inhaled sufficient quantities of DU particulate to incur any significant health risk (i.e., the possibility of temporary kidney damage from the chemical toxicity of uranium and about a 1% chance of fatal lung cancer). The health risk to all downwind civilians is predicted to be extremely small. Recommendations for monitoring are made for certain exposed groups. Although the study found fairly large calculational uncertainties, the models developed and used are generally valid. The analysis was also used to assess potential uranium health hazards for workers in the weapons complex. No illnesses are projected for uranium workers following standard guidelines; nonetheless, some research suggests that more conservative guidelines should be considered.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.