Optical Engine Lockout System
Abstract not provided.
Abstract not provided.
Engine run days in the Diesel Combustion and Fuel Effects Lab are hectic. The long mental lists that must be kept by engine operators, paired with the tight time constraints between experiments, can cause operational issues that may be dangerous to personnel and/or cause damage to test equipment. Until now, a paper sign has been used to warn operators not to motor the engine when a foreign object has been placed inside of it. Unfortunately, this simple administrative control has failed in the past, motivating this effort to develop an improved system. The lockout system described in this document introduces an engineering control that, when activated, actually prevents the engine from being motored. The new system consists of a primary and a secondary control panel. Prior to an operator placing a foreign object into the cylinder, they press a button on the secondary control panel near the engine. This breaks the interlock circuit for the engine dynamometer and activates LEDs on both control panels to notify operators that a foreign object is present within the engine cylinder. Once the work is done and all foreign objects have been removed from the combustion chamber, two operators must be present to disable the system by simultaneously pressing the buttons on the primary and secondary control panels. Requiring a second operator to disable the system increases accountability and reduces the likelihood of potentially costly mistakes.