AIHce 2023 PDC: Sandia Z-Machine & SWiFT: Supplemental Slides for Influencer PDC
Abstract not provided.
Abstract not provided.
The problem statement from which the Causal Analysis Team focused was, "A Member of the Workforce (MOW) from Department 8862 sustained a fractured ankle while traversing a 7.5- inch-high elevated aluminum cover over conduits located in NM Building 905, laboratory 1201 that houses a gas gun." The analysis revealed the following causes that directly contributed to this event: Root Causes: 1. The landing area from the downslope on the flammable cabinet side of the aluminum conduit cover was not sufficient; and 2. The surface of the aluminum conduit cover was too smooth.
The Causal Analysis Team focused on the following problem statement: "A Member of the Workforce (MOW) sustained an electrical shock upon touching a power strip (PS) in a laboratory."