Thermal Hydraulic Static Operation of a Chloride Molten Salt Shut-Off Valve
Madden, Dimitri A.; Overacker, Aaron; Armijo, Kenneth M.; Gosling, Tom
The Sandia National Laboratories (SNL) National Solar Thermal Test Facility (NSTTF) conducted efficacy testing on a shut-off isolation valve for use with molten ternary chloride salt. A ball valve was tested under controlled N2 ullage gas pressure and connected with flanged fittings that featured a spiral-wound gasket. The valve assembly consisted of boronized nickel coated SS316 components, with design features that greatly reduce the cost of overall valve assembly. Testing results showed that the valve did not leak, and post-test analysis demonstrated that the ball, seat, packing, and body all survived both the heat loads and the relative corrosive environment. Spiral-wound gaskets for flanged connections used in the system also functioned nominally, with no leaks or signs of failures during post-test analysis. However, testing was ultimately forced to rapidly stop after testing between 500-530°C as the actuator used on the valve failed in the heat, preventing the valve from sealing in the closed position. In addition, salt plugs and salt vapor plating also prevented the test from continuing.