Publications Details

Publications / Conference

High speed imaging for rash radiography using PIN diodes

Selph, M.M.

A high speed readout imaging system utilizing a commercial flash X-ray machine and miniature X-ray detectors has been developed. This system was designed to operate in the environment near a nuclear detonation where film or camera imaging cannot be used. The temporal resolution of the system is set by the 20 nanosecond FWHM of the X-ray pulse. The spatial resolution of the system was determined by the size and close packing of the PIN diodes used as the X-ray detectors. In the array used here, the PIN diodes have an active area of 2mm in diameter and were placed 3.8mm center to center. Computer-generated images using algorithms developed for this system are presented and compared with an image captured on film in the laboratory.