Publications Details
Evaluation of the metal/adhesive interfaces in the MC2370 fire set
Several analysis methods have been applied to evaluate the structure and composition of the electrode/adhesive interfaces i previously fielded M2370 Fire Sets. A method of interfacial fracture at cryogenic temperatures as been employed to expose regions of these interfaces at multiple levels in a SFE stack. Electron microscopy shows that bond failure induced by the fracture is predominantly adhesive with an equal probability of failure of the Au and Cu interfaces. Some evidence for cohesive, indicative of a possible microstructure related to electrical breakdown. Pinhole-free larger regions of adhesive also exist which may explain the observed high resistance in impedance measurements.