A variety of dose conversion factor files (DCF files) have been supplied for use with the MACCS code since it was initially released. For MACCS 4.2, the MACCS DCF files have been updated to include coefficients used in the computation of acute skin doses from within the MACCS software to increase functionality and to add a pseudo-organ to represent the total effective dose equivalent (TEDE) (as defined in 10 CFR 20.1003) based on International Commission on Radiological Protection (ICRP) Publication 30. This report provides a description of how these changes have been implemented and a summary of the various DCF files supplied with MACCS 4.2. The report also provides supplemental discussions to assist the reader in understanding the technical basis for the MACCS DCFs. These supplemental discussions include a summary of basic dosimetry modeling concepts and a brief review of the Federal Guidance Reports (FGRs) upon which MACCS dose coefficients have historically been based.