Publications Details
Elimination of Heat-Shielding for Geothermal Tools Operating Up To 300 Degress Celsius
Normann, Randy A.; Henfling, Joseph A.
This report focuses Sandia National Laboratories' effort to create high-temperature logging tools for geothermal applications not requiring heat-shielding. Tool electronics can operate up to 300 C with a few limiting components operating to 250 C. Second generation electronics are needed to increase measurement accuracy and extend the operating range to 300 and then 350 C are identified. Custom development of high-temperature batteries and assembling techniques are touched on. Outcomes of this work are discussed and new directions for developing high-temperature industry are suggested.