The self-magnetic pinch (SMP) diode is a type of radiographic diode used to generate an intense electron beam for radiographic applications. At Sandia National Laboratories, SMP was the diode load for the six-cavity radiographic integrated test stand inductive voltage adder (IVA) driver operated in a magnetically insulated transmission line (MITL). The MITL contributes a flow current in addition to the current generated within the diode itself. Extensive experiments with a MITL of 40 ω load impedance [T. J. Renk et al., Phys. Plasmas 29, 023105 (2022)] indicate that the additional flow current leads to results similar to what might be expected from a conventional high-voltage interface driver, where flow current is not present. However, when the MITL flow impedance was increased to 80 ω, qualitatively different diode behavior was observed. This includes large retrapping waves suggestive of an initial coupling to low impedance as well as diode current decreasing with time even as the total current does not. A key observation is that the driver generates total current (flow + diode) consistent with the flow impedance of the MITL used. The case is made in this paper that the 80 ω MITL experiments detailed here can only be understood when the IVA-MITL-SMP diode is considered as a total system. The constraint of fixed total current plus the relatively high flow impedance limits the ability of the diode (whether SMP or other type) to act as an independent load. An unexpected new result is that in tracking the behavior of the electron strike angle on the converter as a function of time, we observed that the conventional cIVx "Radiographic"radiation scaling (where x ∼2.2) begins to break down for voltages above 8 MV, and cubic scaling is required to recover accurate angle tracking.
Radiographic diodes focus on an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the six-cavity radiographic integrated test stand (RITS-6) inductive voltage adder driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode-cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analysis of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below approximately few millimeters. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle behavior of SMP shots is made to lend credence to the inference. There is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.
Radiographic diodes focus an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the RITS-6 Inductive Voltage Adder (IVA) driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode-cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analyzation of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below ~ few mm. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle-behavior of SMP shots is made to lend credence to the inference. There is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.
The goals of an electron beam-driven radiographic source are the focusing of high current at high voltage to a minimal spot size with excellent shot-to-shot reproducibility. The Self-Magnetic Pinch (SMP) diode makes use of such an intense electron beam impinging on a high-atomic weight (tantalum) converter, a counter-streaming ion beam to help minimize the spot size, and operation in a magnetic field-free diode region which further encourages small spot size. Through a series of diode development experiments, output voltages up to 12.5 MV and output currents up to 225 kA have been characterized, with resulting spot sizes below ~ few mm. Scaling studies with parameter variation, such as diode aspect ratio and anode-cathode (A-K) gap variation, give systematic validation to what has heretofore been noted anecdotally by other research groups. While the lack of an imbedded magnetic field helps minimize the SMP spot size, a secondary result may be the generation of beam instabilities which can terminate the radiation pulse. There is anecdotal evidence that in-situ DC heating of the diode region can help stabilize the beam pinch. Clear experimental evidence exists that DC heating/RF cleaning results in better control over the counter-streaming ion population. Expanded use of spatial dose-rate detection is shown to yield new insights into electron beam dynamics in the SMP diode. An attendant study of the SMP diode as a load for an Inductive Voltage Adder (IVA) driver leads to insights into the behavior of the IVA-SMP diode configuration, viewed as a total system, and yields constraints on the overall impedance behavior of the SMP diode load.
Saturn is a short-pulse ( 40 ns FWHM) x-ray generator capable of delivering up 10 MA into a bremsstrahlung diode to yield up 5 × 10^12 rad/s (Si) per shot at an energy of 1 to 2 MeV. With the machine now over 30 years old it is necessary to rebuild and replace many components, upgrade controls and diagnostics, design for more reliability and reproducibility, and, as possible upgrade the accelerator to produce more current at a low voltage ( 1 MV or lower). Thus it has been necessary to reevaluate machine design parameters. The machine is modeled as a simple LR circuit driven with an equivalent a sine-squared drive waveform as peak voltage, drive impedance, and vacuum inductance are varied. Each variation has implications for vacuum insulator voltage, diode voltage, diode impedance, and radiation output. For purposes of this study, radiation is scaled as the diode current times the diode voltage raised to the 2.7 power. Results of parameter scans are presented and used to develop a design that optimizes radiation output. Results indicate that to maintain the existing short pulse length of the machine but to increase output it is most beneficial to operate at an even higher impedance than originally designed. Also discussed are critical improvements that need to be made.
The results presented here were obtained with a self-magnetic pinch (SMP) diode mounted at the front high voltage end of the RITS accelerator. RITS is a Self-Magnetically Insulated Transmission Line (MITL) voltage adder that adds the voltage pulse of six 1.3 MV inductively insulated cavities. The RITS driver together with the SMP diode has produced x-ray spots of the order of 1 mm in diameter and doses adequate for the radiographic imaging of high area density objects. Although, through the years, a number of different types of radiographic electron diodes have been utilized with SABER, HERMES III and RITS accelerators, the SMP diode appears to be the most successful and simplest diode for the radiographic investigation of various objects. Our experiments had two objectives: first to measure the contribution of the back-streaming ion currents emitted from the anode target and second to try to evaluate the energy of those ions and hence the Anode-Cathode (A-K) gap actual voltage. In any very high voltage inductive voltage adder utilizing MITLs to transmit the power to the diode load, the precise knowledge of the accelerating voltage applied on the A-K gap is problematic. This is even more difficult in an SMP diode where the A-K gap is very small (∼1 cm) and the diode region very hostile. The accelerating voltage quoted in the literature is from estimates based on the measurements of the anode and cathode currents of the MITL far upstream from the diode and utilizing the para-potential flow theories and inductive corrections. Thus, it would be interesting to have another independent measurement to evaluate the A-K voltage. The diode's anode is made of a number of high-Z metals in order to produce copious and energetic flash x-rays. It was established experimentally that the back-streaming ion currents are a strong function of the anode materials and their stage of cleanness. We have measured the back-streaming ion currents emitted from the anode and propagating through a hollow cathode tip for various diode configurations and different techniques of target cleaning treatment: namely, heating at very high temperatures with DC and pulsed current, with RF plasma cleaning, and with both plasma cleaning and heating. We have also evaluated the A-K gap voltage by energy filtering technique. Experimental results in comparison with LSP simulations are presented.
We describe the study we have undertaken to evaluate the effect of component tolerances in obtaining a voltage output flat top for a linear transformer driver (LTD) cavity containing 3rd and 5th harmonic bricks [A. A. Kim et al., in Proc. IEEE Pulsed Power and Plasma Science PPPS2013 (San Francisco, California, USA, 2013), pp. 1354-1356.] and for 30 cavity voltage adder. Our goal was to define the necessary component value precision in order to obtain a voltage output flat top with no more than ±0.5% amplitude variation.
Experiments have been conducted at Sandia National Laboratories' RITS-6 accelerator facility [1] (operating at 7.5 MV and 180 kA) investigating plasma formation and propagation in relativistic electron beam diodes used for flash x-ray radiography. High resolution, visible and ultraviolet spectra were collected in the anode-cathode (A-K) vacuum gap of the Self-Magnetic Pinch (SMP) diode [2-4]. Time and space resolved spectra are compared with time-dependent, collisional-radiative (CR) calculations [5-7] and Lsp, hybrid particle-in-cell code simulations [8,9]. Results indicate the presence of a dense (>1x1017cm-3), low temperature (few eV), on-axis plasma, composed of hydrocarbon and metal ion species, which expands at a rate of several cm/s from the anode to the cathode. In addition, cathode plasmas are observed which extend several millimeters into the A-K gap [10]. It is believed that the interaction of these electrode plasmas cause premature impedance collapse of the diode and subsequent reduction in the total radiation output. Diagnostics include high speed imaging and spectroscopy using nanosecond gated ICCD cameras, streak cameras, and photodiode arrays.
We report on an option study of two potential x-ray systems for orthogonal radiography at Area C in the LANSCE facility at Los Alamos National Laboratory. The systems assessed are expected to be near equivalent systems to the presently existing Cygnus capability at the Nevada Test Site. Nominal dose and radiographic resolution of 4 rad (measured at one meter) and 1 mm spot are desired. Both a system study and qualitative design are presented as well as estimated cost and schedule. Each x-ray system analyzed is designed to drive a rod-pinch electron beam diode capable of producing the nominal dose and spot.
This report outlines a convenient method to calibrate fast (<1ns resolution) streaked, fiber optic light collection, spectroscopy systems. Such a system is used to collect spectral data on plasmas generated in the A-K gap of electron beam diodes fielded on the RITS-6 accelerator (8-12MV, 140-200kA). On RITS, light is collected through a small diameter (200 micron) optical fiber and recorded on a fast streak camera at the output of 1 meter Czerny-Turner monochromator (F/7 optics). To calibrate such a system, it is necessary to efficiently couple light from a spectral lamp into a 200 micron diameter fiber, split it into its spectral components, with 10 Angstroms or less resolution, and record it on a streak camera with 1ns or less temporal resolution.
The Sandia Laboratories Advanced Radiographic Technologies Department, in collaboration with the United Kingdom Atomic Weapons Establishment, has been conducting research into the development of the Self-Magnetic-Pinched diode as an x-ray source suitable for flash radiographic experiments. We have demonstrated that this source is capable of meeting and exceeding the initial requirements of 250 rads (measured at one meter) with a 2.75 mm source spot-size. Recent experiments conducted on the RITS-6 accelerator have demonstrated the ability of this diode to meet intermediate requirements with a sub 3 mm source spot size and a dose in excess of 400 rads at one meter.
Pulsed power driven flash x-ray radiography is a valuable diagnostic for subcritical experiments at the Nevada Test Site. The existing dual-axis Cygnus system produces images using a 2.25 MV electron beam diode to produce intense x-rays from a small source. Future hydrodynamic experiments will likely use objects with higher areal mass, requiring increased x-ray dose and higher voltages while maintaining small source spot size. A linear transformer driver (LTD) is a compact pulsed power technology with applications ranging from pulsed power flash x-ray radiography to high current Z-pinch accelerators. This report describes the design of a 7-MV dual-axis system that occupies the same lab space as the Cygnus accelerators. The work builds on a design proposed in a previous report [1]. This new design provides increased diode voltage from a lower impedance accelerator to improve coupling to low impedance diodes such as the self magnetic pinch (SMP) diode. The design also improves the predicted reliability by operating at a lower charge voltage and removing components that have proven vulnerable to failure. Simulations of the new design and experimental results of the 1-MV prototype are presented.
The development of plasma sources with densities and temperatures in the 10{sup 15}-10{sup 17} cm{sup -3} and 1-10eV ranges which are slowly varying over several hundreds of nanoseconds within several cubic centimeter volumes is of interest for applications such as intense electron beam focusing as part of the x-ray radiography program. In particular, theoretical work [1,2] suggests that replacing neutral gas in electron beam focusing cells with highly conductive, pre-ionized plasma increases the time-averaged e-beam intensity on target, resulting in brighter x-ray sources. This LDRD project was an attempt to generate such a plasma source from fine metal wires. A high voltage (20-60kV), high current (12-45kA) capacitive discharge was sent through a 100 {micro}m diameter aluminum wire forming a plasma. The plasma's expansion was measured in time and space using spectroscopic techniques. Lineshapes and intensities from various plasma species were used to determine electron and ion densities and temperatures. Electron densities from the mid-10{sup 15} to mid-10{sup 16} cm{sup -3} were generated with corresponding electron temperatures of between 1 and 10eV. These parameters were measured at distances of up to 1.85 cm from the wire surface at times in excess of 1 {micro}s from the initial wire breakdown event. In addition, a hydrocarbon plasma from surface contaminants on the wire was also measured. Control of these contaminants by judicious choice of wire material, size, and/or surface coating allows for the ability to generate plasmas with similar density and temperature to those given above, but with lower atomic masses.