Publications Details

Publications / Report

Vibration and shock test report for the H1616-1 container and the Savannah River Hydride Transport Vessel

York II, A.R.; Joseph, B.J.

Sandia National Laboratories performed random vibration and shock tests on a tritium hydride transport vessel that was packaged in an H1616-1 container. The objective of the tests was to determine if the hydride transport vessel remains leaktight under vibration and shock normally incident to transport, which is a requirement that the hydride transport vessel must meet to be shipped in the H1616-1. Helium leak tests before and after the vibration and shock tests showed that the hydride transport vessel remained leaktight under the specified conditions. There were no detrimental effects on the containment vessel of the H1616-1.