Results of video height of charge measurement for MIDDLE KEY 4
This report describes the Height of Charge measurement for the Middle Key 4 test conducted at the FCDNA Permanent High Explosives Test Site (PHETS) on 17 September, 1993. The object of the measurement was to monitor remotely the change in the height of the explosive charge suspended above the test pad once the site had been evacuated until detonation. Should the measurement have shown that the charge changed height by more than 15cm then a hold in the test was to be called so that a height adjustment in the suspension system could be made. The measurement system consisted of a remotely placed video camera linked to the test control center-based measurement computer via a fiber optical video data link, a pole mounted stationary reference target, and a target mounted on the charge bag. Measurement of the change in height was determined using image analysis software on frame grabbed images. Measurements indicate that the charge bag did not deviate from the initial surveyed height of 1747cm by more than 1cm between the last measurement made by the survey crew until detonation 40 minutes later.