Publications Details

Publications / Report

Repetitive High Energy Pulsed Power (RHEPP) Temperature Monitoring System utilizing Luxtron fluoroptic sensors and thermocouples technical reference manual

Laderach, G.E.

This document describes the Temperature Monitoring System for the RHEPP project at Sandia National Laboratories. The system is designed to operate in the presence of severe repetitive high voltage and electromagnetic fields while providing real time thermal data on component behavior. The thermal data is used in the design and evaluation of the major RHEPP components such as the magnetically switched pulse compressor and the linear induction voltage adder. Particular attention is given to the integration of commercially available hardware and software components with a custom written control program. While this document is intended to be a reference guide, it may also serve as a template for similar applications. 3 refs.