Publications Details

Publications / Report

Oxygen Deficiency Monitor System

Devlin, G.L.

This report describes the components and installation of the Oxygen Deficiency Monitor System (ODMS) at the Simulation Technology Laboratory (STL) at Sandia National Laboratories. The ODMS presently monitors the oxygen concentration of the ambient air in the lower levels of the laboratory where air circulation may be insufficient to disperse gases that may settle and accumulate creating an oxygen-deficient environment. The intent of this report is to provide a general introduction to the system for personnel involved in the maintenance and modifications of the system and may be useful to people interested in installing a similar system. This will report describe the hardware components, installation considerations, operation, and maintenance of the system. 6 refs., 5 figs.