Struve, K.W.; Welch, D.R.; Frost, C.A.; Crist, C.E.

During the RADLAC II open-air beam propagation experiments this last year three separate optical diagnostics were used. (1) Streak cameras were deployed to measure matched beam radius and centroid versus time. (2) Three gated, intensified TV cameras were used to image the beam from the end of the propagation range. They gave beam radius and centroid for three slices of the beam over a five meter propagation length. (3) Open shutter cameras were developed to give the time-averaged beam position over the entire propagation range. Data from all three diagnostics were digitized, stored in files on a computer, and post-processed to give temporally and spatially resolved beam size and position. These diagnostics used beam induced air-fluorescence as the mechanism to provide a prompt signal representative of the beam current density. Previous experiments and analysis have shown that the radiation is prompt with the intensity proportional to the beam current density for high energy, high current electron beams propagating in full density air.