Publications Details
MELCOR analyses of drywell flammability
The MELCOR computer code, which has been developed at Sandia National Laboratories for the US Nuclear Regulatory Commission as a tool for calculating realistic estimates of severe accident consequences and source terms, has been used to analyze a series of containment issues for station blackout sequences for the Grand Gulf Nuclear Power Plant. The results indicate that there is a limited time interval in which the drywell atmosphere would be flammable, and that this would only occur if the vacuum breaker were to stick open within a narrow time window. If burning does occur during this time, it appears quite likely that it would not pose a threat to the drywell wall. The main conclusion from this study is that the drywell atmosphere is not very likely to be flammable for a station blackout sequence. 1 ref. (S.J.)