Publications Details
Magnetic-field shielding of satellites from high-energy-electron environments
Magnet configurations are found that limit the 6-MeV electrons threatening satellite electronics to <1% of the incident flux. Successful configurations of permanent magnets and electromagnets require magnetic energies of {approximately}8 to 12 kJ to protect each liter of electronics volume. The fundamental strength of materials leads to a required minimum mass of {approximately}48 to 64 kg/liter to support the magnetic pressure. With the electronics requiring {approximately}5 liters, several hundred kilograms are needed for this support. Except for protecting small apertures, magnetic shielding provides little, if any, advantage over that obtained by coating with an equivalent mass using traditional methods. 7 refs., 9 figs., 1 tab.