Publications Details
Large-scale brine inflow data report for room Q prior to November 25, 1991
Jensen, A.L.
A large-scale brine inflow test was conducted 655 m below ground surface in a cylindrical test room at the Waste Isolation Pilot Plant (WIPP). This test was the first large-scale WIPP test that allowed periodic access to a sealed, monitored excavation. The test was designed to characterize the environment within the sealed test room (Room Q) and to examine the surrounding host rock to quantify such characteristics as near-surface resistivity and permeability in the formation surrounding the room. Testing began with room boring in July 1989. Data in this report were collected from the time of test start-up through November 25, 1991. Relative humidity, barometric pressure, and temperature were measured in the sealed environment of the test room. Formation closure rates and electrical resistance of the formation close to the room surface were measured to determine the response of the host rock around Room Q. Brine was collected periodically to quantify the amount of inflow from large-scale openings. Results of the measurements are presented in a series of graphs. This report also describes the features of the test