J/sub Ic/ fracture toughness of ferritic DCI (ductile cast iron) alloys: A comparison of two versions of ASTM E 813

Salzbrenner, R.

The fracture toughness of several ductile cast iron (DCI) alloys has been calculated according to two versions of the ASTM Standard covering the determination of J/sub Ic/. The original version (ASTM E 813-81) had previously been used to establish the relationship between ferritic DCI alloys and the graphite nodule spacing. The J/sub Ic/ values were recalculated by the methods of the revised version of the ASTM Standard (ASME 813-87), and were found to be 5 to 8% higher than those determined by the original standard. A linear regression analysis was used to reaffirm that the fracture toughness is directly related to the graphite nodule size or spacing. 6 refs., 8 figs., 3 tabs.