Publications Details

Publications / Conference

Ion exchange of cesium by crystalline silico-titanates

Miller, James E.

The crystalline silico-titanates developed by the Department of Chemical Engineering at Texas A&M University, Sandia National Laboratories and UOP exhibits extremely high ion exchange selectivity for removing cesium from aqueous defense wastes. Based on experimental data and structure studies, a competitive ion exchange model was proposed to predict the ion exchange performance in different simulated waste solutions. The predicted distribution coefficients were within 10% of the experimentally determined values.