Publications Details
Effect of atmospheric variations on electromagnetic distance measurements
Solomon Jr., O.M.
This report describes some field tests of the CUBIC CR-100 distance measuring equipment. The distance measurements depend on the refractivity of the atmospheric. The CR-100 uses 320 for the refractivity. For the Albuquerque area on a clear spring day, 220 is a more realistic value for refractivity. This difference of 100 between the actual and assumed refractivities causes the range error to accumulate at the rate of 1 meter per 10,000 meters of range. For example, a difference of 100 in refractivity forces the measured range to contain an error of 5 meters for a 50,000 meter baseline. 12 figs.