Publications Details
Causal Analysis Report for Thunder Range Block VIII Test - Management Concern
From July 24th -27th, 2018, Sandia National Laboratories (SNL) was conducting a series of explosive tests (referred to as Block VIII Tests) at Thunder Range. Thunder Range is an explosive testing range located on Kirtland Air Force Base and operated by SNL. The testing occurred on Range 7, a fragmentation range that is authorized for activities up to a maximum of 2,000 pounds net explosive weight (NEW). The maximum NEW for the Block VIII tests was 114 lbs. The specific management concern is that although the Thunder Range team identified controls to provide protection for essential personnel, those controls were not adequately evaluated before testing occurred. There were several controls in place at Thunder Range when the block VW test was executed. Engineered controls including Fire Control Point (FCP) placement, FCP structure design, and administrative controls involving communications. These controls were in place but not thoroughly evaluated for adequacy in meeting requirements related to sound pressure and fragments before the test was executed. Compliance with the remaining requirements was achieved. The lack of evaluation did not result in harm to personnel, equipment, or structures but was deemed as an opportunity to further understand how compliance with DOE-STD-1212-2012 could be better achieved with defensible evidence. The information provided in the remainder of this report discusses these controls and the deficiencies that contributed to this management concern.