Publications Details

Publications / Conference

An Intense Large-Volume Uniform Source of Bremsstrahlung for Pulsed Gamma Ray Simulation

Sanford, Thomas W.

The intense radiation fields generated with useful uniformity over large volumes, using the novel compound-lens diode on Hermes III, are characterized. The measurements show that by changing the diode parameters, the peak dose, useful area, and useful volume of irradiation can be varied from ~100 krad(Si), ~600 cm2, and ~20×103 cm3 to 20 krad(Si), ~3400 cm2, and ~200×103 cm3, in a 19±2 ns radiation pulse. This versatility enables radiation fields to be tailored to a specified exposure requirement, significantly enhancing the capability of Hermes III to test radiation effects in systems. © 1992 IEEE