US Experience with Inverter Interoperability Standardization
Abstract not provided.
Abstract not provided.
This report provides an introduction to cyber security for distributed energy resources (DER) - such as photovoltaic (PV) inverters and energy storage systems (ESS). This material is motivated by the need to assist DER vendors, aggregators, grid operators, and broader PV industry with cyber security resilience and describe the state-of-the-art for securing DER communications. The report outlines basic principles of cyber security, encryption, communication protocols, DER cyber security recommendations and requirements, and device-, aggregator-, and utility-level security best practices to ensure data confidentiality, integrity, and availability. Example cyber security attacks, including eavesdropping, masquerading, man-in-the-middle, replay attacks, and denial-of-service are also described. A survey of communication protocols and cyber security recommendations used by the DER and power system industry are included to elucidate the cyber security standards landscape. Lastly, a roadmap is presented to harden end-to-end communications for DER with research and industry engagement.
For three years, Sandia National Laboratories, Georgia Institute of Technology, and University of Illinois at Urbana-Champaign investigated a smart grid vision in which renewable-centric Virtual Power Plants (VPPs) provided ancillary services with interoperable distributed energy resources (DER). This team researched, designed, built, and evaluated real-time VPP designs incorporating DER forecasting, stochastic optimization, controls, and cyber security to construct a system capable of delivering reliable ancillary services, which have been traditionally provided by large power plants or other dedicated equipment. VPPs have become possible through an evolving landscape of state and national interconnection standards, which now require DER to include grid-support functionality and communications capabilities. This makes it possible for third party aggregators to provide a range of critical grid services such as voltage regulation, frequency regulation, and contingency reserves to grid operators. This paradigm (a) enables renewable energy, demand response, and energy storage to participate in grid operations and provide grid services, (b) improves grid reliability by providing additional operating reserves for utilities, independent system operators (ISOs), and regional transmission organization (RTOs), and (c) removes renewable energy high-penetration barriers by providing services with photovoltaics and wind resources that traditionally were the jobs of thermal generators. Therefore, it is believed VPP deployment will have far-reaching positive consequences for grid operations and may provide a robust pathway to high penetrations of renewables on US power systems. In this report, we design VPPs to provide a range of grid-support services and demonstrate one VPP which simultaneously provides bulk-system energy and ancillary reserves.
This report presents an object-oriented implementation of full state feedback control for virtual power plants (VPP). The components of the VPP full state feedback control are (1) objectoriented high-fidelity modeling for all devices in the VPP; (2) Distribution System Distributed Quasi-Dynamic State Estimation (DS-DQSE) that enables full observability of the VPP by augmenting actual measurements with virtual, derived and pseudo measurements and performing the Quasi-Dynamic State Estimation (QSE) in a distributed manner, and (3) automated formulation of the Optimal Power Flow (OPF) in real time using the output of the DS-DQSE, and solving the distributed OPF to provide the optimal control commands to the DERs of the VPP.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Conference Record of the IEEE Photovoltaic Specialists Conference
Abstract not provided.
Abstract not provided.
Abstract not provided.
2017 IEEE 44th Photovoltaic Specialist Conference, PVSC 2017
Photovoltaic (PV) distributed energy resources (DER) have reached approximately 27 GW in the U.S., and the solar penetration rate continues to increase. This growth is expected to continue, causing challenges for grid operators who must maintain grid stability, reliability, and resiliency. To minimize adverse effects on the performance of electrical power system (EPS) with increasing levels of variable renewable generation, photovoltaic inverters must implement grid-support capabilities, allowing the DER to actively participate in grid support operations and remain connected during short-term voltage and frequency anomalies. These functions include voltage and frequency regulation features that adjust DER active and reactive power at the point of common coupling. To evaluate the risk of these functions conflicting with traditional distribution system voltage regulation equipment, researchers used several methods to quantify EPS-support function response times for autonomous voltage regulation functions (volt-var function). Based on this study, no adverse interactions between PV inverters with volt-var functions and load tap changing transformers or capacitor banks were discovered.
2017 IEEE 44th Photovoltaic Specialist Conference, PVSC 2017
Photovoltaic (PV) distributed energy resources (DER) have reached approximately 27 GW in the U.S., and the solar penetration rate continues to increase. This growth is expected to continue, causing challenges for grid operators who must maintain grid stability, reliability, and resiliency. To minimize adverse effects on the performance of electrical power system (EPS) with increasing levels of variable renewable generation, photovoltaic inverters must implement grid-support capabilities, allowing the DER to actively participate in grid support operations and remain connected during short-term voltage and frequency anomalies. These functions include voltage and frequency regulation features that adjust DER active and reactive power at the point of common coupling. To evaluate the risk of these functions conflicting with traditional distribution system voltage regulation equipment, researchers used several methods to quantify EPS-support function response times for autonomous voltage regulation functions (volt-var function). Based on this study, no adverse interactions between PV inverters with volt-var functions and load tap changing transformers or capacitor banks were discovered.
Abstract not provided.
With the rapidly changing landscape of grid codes and interconnection standards, manufacturers of DER components are under increasing pressure to reliably update and validate the interoperability and performance of their equipment for different regional requirements and grid conditions. To help vendors meet these standards, AIT and Sandia have teamed up and introduced an approach for the rapid, concurrent development of controls and application software through a controller hardware-in-the-loop (CHIL) testbed integrated with an automated testing platform.
While arc-faults are rare in electrical installations, many documented events have led to fires that resulted in significant damage to energy-generation, commercial and residential systems, as well as surrounding structures, in both the United States and abroad. Arc-plasma discharges arise over time due to a variety of reliability issues related to cable material degradation, electrical and mechanical stresses or acute conductive wiring dislocations. These may lead to discontinuity between energized conductors, facilitating arcing events and fires. Arc-flash events rapidly release significant energy in a localized volume, where the electric arc experiences a reduction in resistance. This facilitates a reduction in electrical resistance as the arc temperature and pressure can increase rapidly. Strong pressure waves, electromagnetic interference (EMI), and intense light from an arc pose a threat to electrical worker safety and system equipment. This arc-fault primer provides basic fundamental insight into arc-fault plasma discharges, and an overview of direct current (DC) and alternating current (AC) arc-fault phenomena. This primer also covers pressure waves and EMI arc-fault hazard analyses related to incident energy prediction and potential damage analysis. Mitigation strategies are also discussed related to engineering design and employment of protective devices including arc-fault circuit interrupters (AFCIs). Best practices related to worker safety are also covered, especially as they pertain to electrical codes and standards, particularly Institute of Electrical and Electronics Engineers (IEEE) 1584 and National Fire Protection Agency (NFPA) 70E. Throughout the primer various modelling and test capabilities at Sandia National Laboratories are also covered, especially as they relate to novel methods of arc-fault/arc-flash characterization and mitigation approaches. Herein, this work describes methods for producing and characterizing controlled, sustained arcs at atmospheric pressures as well as methods for mitigation with novel materials.
IEEE Journal of Photovoltaics
When renewable energy resources are installed in electricity grids, they typically increase generation variability and displace thermal generator control action and inertia. Grid operators combat these emerging challenges with advanced distributed energy resource (DER) functions to support frequency and provide voltage regulation and protection mechanisms. This paper focuses on providing frequency reserves using autonomous IEC TR 61850-90-7 pointwise frequency-watt (FW) functions that adjust DER active power as a function of measured grid frequency. The importance of incorporating FW functions into a fleet of photovoltaic (PV) systems is demonstrated in simulation. Effects of FW curve design, including curtailment, deadband, and droop, were analyzed against performance metrics using Latin hypercube sampling for 20%, 70%, and 120% PV penetration scenarios on the Hawaiian island of Lanai. Finally, to understand the financial implications of FW functions to utilities, a performance function was defined based on monetary costs attributable to curtailed PV production, load shedding, and generator wear. An optimization wrapper was then created to find the best FW function curve for each penetration level. It was found that in all cases, the utility would save money by implementing appropriate FW functions.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
IEA Implementing Agreement for International Smart Grid Action Network, a Cooperative Program on Smart Grids (ISGAN) discussion papers are meant as input documents to the global discussion about smart grids. Each is a statement by the author(s) regarding a topic of international interest. They reflect works in progress in the development of smart grids in the different regions of the world. Their aim is not to communicate a final outcome or to advise decision-makers, but rather to lay the ground work for further research and analysis. In this report, SIRFN laboratories (Sandia, AIT, RSE and FREA) establish a harmonized Battery Energy Storage System (BESS) evaluation/certification protocol for advanced energy storage functions. The authors present this standardized protocol as an adoption or revision option for jurisdictions when creating or modifying certification testing requirements. To complete this process, each laboratory shared information on national, international, and jurisdictional grid codes and standards for BESS. Based on these requirements, and BESS testing and certification literature, a broad list of interoperability functions, use cases, storage capabilities, and requirements were compiled. This list was then consolidated to a unique set of BESS functions for inclusion in the certification procedure. Draft certification protocols for five initial functions were created by the SIRFN group in order to harmonize the international effort to establish a unified set of procedures for interoperability testing of BESS.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Journal of Solar Energy
The increasing pressure for network operators to meet distribution network power quality standards with increasing peak loads, renewable energy targets, and advances in automated distributed power electronics and communications is forcing policy-makers to understand new means to distribute costs and benefits within electricity markets. Discussions surrounding how distributed generation (DG) exhibits active voltage regulation and power factor/reactive power control and other power quality capabilities are complicated by uncertainties of baseline local distribution network power quality and to whom and how costs and benefits of improved electricity infrastructure will be allocated. DG providing ancillary services that dynamically respond to the network characteristics could lead to major network improvements. With proper market structures renewable energy systems could greatly improve power quality on distribution systems with nearly no additional cost to the grid operators. Renewable DG does have variability challenges, though this issue can be overcome with energy storage, forecasting, and advanced inverter functionality. This paper presents real data from a large-scale grid-connected PV array with large-scale storage and explores effective mitigation measures for PV system variability. As a result, we discuss useful inverter technical knowledge for policy-makers to mitigate ongoing inflation of electricity network tariff components by new DG interconnection requirements or electricity markets which value power quality and control.
We have examined ground faults in PhotoVoltaic (PV) arrays and the efficacy of fuse, current detection (RCD), current sense monitoring/relays (CSM), isolation/insulation (Riso) monitoring, and Ground Fault Detection and Isolation (GFID) using simulations based on a Simulation Program with Integrated Circuit Emphasis SPICE ground fault circuit model, experimental ground faults installed on real arrays, and theoretical equations.
Abstract not provided.
Increasing the penetration of distributed renewable sources, including photovoltaic (PV) sources, poses technical challenges for grid management. The grid has been optimized over decades to rely upon large centralized power plants with well-established feedback controls, but now non-dispatchable, renewable sources are displacing these controllable generators. This one-year study was funded by the Department of Energy (DOE) SunShot program and is intended to better utilize those variable resources by providing electric utilities with the tools to implement frequency regulation and primary frequency reserves using aggregated renewable resources, known as a virtual power plant. The goal is to eventually enable the integration of 100s of Gigawatts into US power systems.
Increasing the penetration of distributed renewable sources, including photovoltaic (PV) generators, poses technical challenges for grid management. The grid has been optimized over decades to rely on large centralized power plants with well-established feedback controls. Conventional generators provide relatively constant dispatchable power and help to regulate both voltage and frequency. In contrast, photovoltaic (PV) power is variable, is only as predictable as the weather, and provides no control action. Thus, as conventional generation is displaced by PV power, utility operation stake holders are concerned about managing fluctuations in grid voltage and frequency. Furthermore, since the operation of these distributed resources are bound by certain rules that require they stop delivering power when measured voltage or frequency deviate from the nominal operating point, there are also concerns that a single grid event may cause a large fraction of generation to turn off, triggering a black out or break-up of an electric power system.
The continued exponential growth of photovoltaic technologies paves a path to a solar-powered world, but requires continued progress toward low-cost, high-reliability, high-performance photovoltaic (PV) systems. High reliability is an essential element in achieving low-cost solar electricity by reducing operation and maintenance (O&M) costs and extending system lifetime and availability, but these attributes are difficult to verify at the time of installation. Utilities, financiers, homeowners, and planners are demanding this information in order to evaluate their financial risk as a prerequisite to large investments. Reliability research and development (R&D) is needed to build market confidence by improving product reliability and by improving predictions of system availability, O&M cost, and lifetime. This project is focused on understanding, predicting, and improving the reliability of PV systems. The two areas being pursued include PV arc-fault and ground fault issues, and inverter reliability.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
International Journal of Renewable Energy Research (IJRER)
Abstract not provided.
Abstract not provided.
Abstract not provided.