Publications

Results 1–100 of 242

Search results

Jump to search filters

Response of a high-pressure 4He scintillation detector to nuclear recoils up to 9 MeV

Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Searfus, O.; Marleau, P.; Jovanovic, I.

Helium-4-based scintillation detector technology is emerging as a strong alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, particularly in extreme gamma-ray environments. The 4He detector is intrinsically insensitive to gamma radiation, as it has a relatively low cross-section for gamma-ray interactions, and the stopping power of electrons in the 4He medium is low compared to that of 4He recoil nuclei. Consequently, gamma rays can be discriminated by simple energy deposition thresholding instead of the more complex pulse shape analysis. The energy resolution of 4He scintillation detectors has not yet been well-characterized over a broad range of energy depositions, which limits the ability to deconvolve the source spectra. In this work, an experiment was performed to characterize the response of an Arktis S670 4He detector to nuclear recoils up to 9 MeV. The 4He detector was positioned in the center of a semicircular array of organic scintillation detectors operated in coincidence. Deuterium–deuterium and deuterium–tritium neutron generators provided monoenergetic neutrons, yielding geometrically constrained nuclear recoils ranging from 0.0925 to 8.87 MeV. The detector response provides evidence for scintillation linearity beyond the previously reported energy range. The measured response was used to develop an energy resolution function applicable to this energy range for use in high-fidelity detector simulations needed by future applications.

More Details

Response of a high-pressure 4He scintillation detector to nuclear recoils up to 9 MeV

Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment

Searfus, O.; Marleau, P.; Jovanovic, Igor

Helium-4-based scintillation detector technology is emerging as a strong alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, particularly in extreme gamma-ray environments. The 4He detector is intrinsically insensitive to gamma radiation, as it has a relatively low cross-section for gamma-ray interactions, and the stopping power of electrons in the 4He medium is low compared to that of 4He recoil nuclei. Consequently, gamma rays can be discriminated by simple energy deposition thresholding instead of the more complex pulse shape analysis. The energy resolution of 4He scintillation detectors has not yet been well-characterized over a broad range of energy depositions, which limits the ability to deconvolve the source spectra. In this work, an experiment was performed to characterize the response of an Arktis S670 4He detector to nuclear recoils up to 9 MeV. The 4He detector was positioned in the center of a semicircular array of organic scintillation detectors operated in coincidence. Deuterium–deuterium and deuterium–tritium neutron generators provided monoenergetic neutrons, yielding geometrically constrained nuclear recoils ranging from 0.0925 to 8.87 MeV. The detector response provides evidence for scintillation linearity beyond the previously reported energy range. Finally, the measured response was used to develop an energy resolution function applicable to this energy range for use in high-fidelity detector simulations needed by future applications.

More Details

Spherical time-encoded radiation imaging simulations

Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Kuchta, John R.; Trimas, David J.; Marleau, P.; Wehe, David K.

Radiation source localization is important for nuclear nonproliferation and can be obtained using time-encoded imaging systems with unsegmented detectors. A scintillation crystal can be used with a moving coded-aperture mask to vary the detected count rate produced from radiation sources in the far field. The modulation of observed counts over time can be used to reconstruct an image with the known coded-aperture mask pattern. Current time-encoded imaging systems incorporate cylindrical coded-aperture masks and have limits to their fully coded imaging field-of-view. This work focuses on expanding the field-of-view to 4π by using a novel spherical coded-aperture mask. A regular icosahedron is used to approximate a spherical mask. This icosahedron consists of 20 equilateral triangles; the faces of which are each subdivided into four equilateral triangle-shaped voxels which are then projected onto a spherical surface, creating an 80-voxel coded-aperture mask. These polygonal voxels can be made from high-Z materials for gamma-ray modulation and/or low-Z materials for neutron modulation. In this work, we present Monte Carlo N-Particle (MCNP) simulations and simple models programmed in Mathematica to explore image reconstruction capabilities of this 80-voxel coded-aperture mask.

More Details

A comparison of the neutron detection efficiency and response characteristics of two pixelated PSD-capable organic scintillator detectors with different photo-detection readout methods

Journal of Instrumentation

Marleau, P.; Sweany, Melinda D.; Balajthy, Jon A.

We characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved performance over the previously developed PMT-based detector both in terms of uniformity and neutron detection efficiency. Each detector array uses PSD-capable plastic scintillator as a detection medium. We describe the calibration and neutron efficiency measurement of both detectors using a 137Cs source for energy calibration and a 252Cf source for calibration of the neutron response. We find that the intrinsic neutron detection efficiency of the SiPM-based array is (30.2 ± 0.9)%, which is almost twice that of the PMT-based array, which we measure to be (16.9 ± 0.1)%.

More Details

Passive and active neutron signatures of 233U for nondestructive assay

Physical Review Applied

Searfus, O.; Marleau, P.; Uribe, Eva U.; Reedy, Heather A.; Jovanovic, Igor

The thorium fuel cycle is emerging as an attractive alternative to conventional nuclear fuel cycles, as it does not require the enrichment of uranium for long-term sustainability. The operating principle of this fuel cycle is the irradiation of 232Th to produce 233U, which is fissile and sustains the fission chain reaction. 233U poses unique challenges for nuclear safeguards, as it is associated with a uniquely extreme γ-ray environment from 232U contamination, which limits the feasibility of the γ-ray-based assay, as well as more conservative accountability requirements than for 235U set by the International Atomic Energy Agency. Consequently, instrumentation used for safeguarding 235U in traditional fuel cycles may be inapplicable. It is essential that the nondestructive signatures of 233U be characterized so that nuclear safeguards can be applied to thorium fuel-cycle facilities as they come online. In this work, a set of 233U3O8 plates, containing 984 g233U, was measured at the National Criticality Experiments Research Center. A high-pressure 4He gaseous scintillation detector, which is insensitive to γ-rays, was used to perform a passive fast neutron spectral signature measurement of 233U3O8, and was used in conjunction with a pulsed deuterium-tritium neutron generator to demonstrate the differential die-away signature of this material. Furthermore, an array of 3He detectors was used in conjunction with the same neutron generator to measure the delayed neutron time profile of 233U, which is unique to this nuclide. These measurements provide a benchmark for future nondestructive assay instrumentation development, and demonstrate a set of key neutron signatures to be leveraged for nuclear safeguards in the thorium fuel cycle.

More Details

Pulse shape measurements for neutron/gamma discrimination using the TOFPET2 ASIC

Journal of Instrumentation

Sweany, Melinda D.; Weinfurther, Kyle J.; Marleau, P.

Many highly pixelated organic scintillator detection systems would benefit from independent readout of each scintillator pixel. Recent advances in Silicon Photomultiplier (SiPM) technology makes this goal feasible, however the data acquisition from potentially hundreds or thousands of channels requires a low-cost and compact solution. For pixelated neutron detection with organic scintillators, the capability to distinguish between neutron and gamma interactions using Pulse Shape Discrimination (PSD) is required along with pulse charge and time of arrival. The TOFPET2 ASIC from PETsys Electronics is a 64-channel readout chip providing pulse time and charge integration measurements from SiPMs, and is specifically designed for time-of-flight positron-emission tomography. Using an 8 × 8 array of 6 mm × 6 mm J-series SiPMs from SensL/OnSemi (ArrayJ-60035-64P-PCB), we have studied the energy and PSD performance of the TOFPET2 ASIC using a 4 × 4 array of 6 mm × 6 mm × 30 mm trans-Stilbene crystals from Inrad Optics and a custom SiPM routing board from PETsys Electronics. Using a time-over-threshold method, we measure a maximum PSD figure-of-merit of approximately 1.2 at 478 keV (the Compton edge of 662 keV) for a J-series SiPM operating at an over-voltage of 3V.

More Details

System Response Characterization for a d–t Neutron Radiography System

Sweany, Melinda D.; Weinfurther, Kyle J.; Sjoberg, Kurt C.; Marleau, P.

We report the system response of a pixelated associated particle imaging (API) neutron radiography system. The detector readout currently consists of a 2x2 array of organic glass scintillator detectors, each with an 8x8 array of optically isolated pixels that match the size and pitch of the ARRAYJ-60035-64P-PCB Silicon Photomultiplier (SiPM) array from SensL/onsemi with 6x6 mm2 SiPMs. The alpha screen of the API deuterium-tritium neutron generator is read out with the S13361-3050AE-08 from Hamamatsu, which is an 8x8 array of 3x3 mm2 SiPMs. Data from the 320 channel system is acquired with the TOFPET2-based readout system. We present the predicted imaging capability of an eventual 5x5 detector array, the waveform-based energy and pulse shape characterization of the individual detectors, and the timing and energy response from the TOFPET2 system.

More Details

Open Radiation Monitoring: Conceptual System Design

Polack, John K.; Brubaker, E.; Hamel, Michael C.; Kiff, Scott; Marleau, P.; Maierhafer, Daniel; Padilla, Eduardo A.; Weber, Thomas M.

The Open Radiation Monitoring (ORM) Project seeks to develop and demonstrate a modular radiation detection architecture designed specifically for use in arms control treaty verification (ACTV) applications that will facilitate rapid development of trusted systems to meet the needs of potential future treaties. Development of trusted systems to support potential future treaties is a complex and costly endeavor that typically results in a purpose-built system designed to perform one specific task. The majority of prior trusted system development efforts have relied on the use of commercial embedded computers or microprocessors to control the system and process the acquired data. These processors are complex, making authentication and certification of measurement systems and collected data challenging and time consuming. We believe that a modular architecture can be used to reduce more complex systems to a series of single-purpose building blocks that could be used to implement a variety of detection modalities with shared functionalities. With proper design, the functionality of individual modules can be confirmed through simple input/output testing, thereby facilitating equipment inspection and in turn building trust in the equipment by all treaty parties. Furthermore, a modular architecture can be used to control data flow within the measurement system, reducing the risk of "hidden switches" and constraining the amount of sensitive information that could potentially be inadvertently leaked. This report documents a conceptual modular system architecture that is designed to facilitate inspection in an effort to reduce overall authentication and certification burden. As of publication, this architecture remains in a conceptual phase and additional funding is required to prove out the utility of a modular architecture and test the assumptions used to rationalize the design.

More Details

Open Radiation Monitoring: Histogram Builder Module Design

Maierhafer, Daniel; Polack, John K.; Marleau, P.; Hammon, Steven; Helguero, Rachel R.; Geyer, Christian

The Open Radiation Monitoring Project seeks to develop and demonstrate a modular radiation detection architecture designed specifically for use in arms control treaty verification (ACTV) applications that will facilitate rapid development of trusted systems to meet the needs of potential future treaties. A modular architecture can be used to reduce more complex systems to a series of single purpose building blocks, thereby facilitating equipment inspection and in turn building trust in the equipment by all treaty parties. Furthermore, a modular architecture can be used to control data flow within the measurement system, reducing the risk of "hidden switches" and constraining the amount of sensitive information that could potentially be inadvertently leaked. This report details the first revision of a prototype circuit that will convert analog pulses directly into a histogrammed data set for further processing. The circuit was designed with both spectroscopy and multiplicity analysis in mind but can, in principle, be used to reduce any raw data stream into a histogram. The number of output channels is limited, and the histogram bin ranges are user configurable to allow for non-uniform and discontinuous bins, which makes it possible to restrict the information being passed down stream if desired. Pulse processing relies entirely on analog circuitry and non- programmable logic, which enables operation without the need for a central processor or other programmable control unit. The circuit remains untested under the Open Radiation Monitoring project due to the closure of the sponsoring program. However, further development and testing is scheduled to take place in support of a purpose-built trusted verification system development effort known as COGNIZANT, which demonstrates the potential benefit of developing a suite of modular trusted system components.

More Details

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System from Adaptive Detector Movements

IEEE Transactions on Nuclear Science

Shah, Niral P.; Marleau, P.; Fessler, Jeffrey A.; Chichester, David L.; Wehe, David K.

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. We propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are 10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

More Details

Single Volume Scatter Camera: Optically Segmented Effort - Single Slide Overview

Sweany, Melinda D.; Adamek, E.; Alhajaji, H.; Brown, James R.; Balathy, John; Brubaker, E.; Cabrera-Palmer, B.; Cates, J.C.B.; Dorril, R.; Druetzler, A.; Elam, J.; Febbraro, M.; Feng, Patrick L.; Folsom, Michael W.; Gabella, G.; Galindo-Tellez, A.; Goldblum, B.; Hausladen, P.; Kaneshige, N.; Keffe, Kevin; Laplace, T.A.; Maggi, Paul; Mane, A.; Manfredi, J.; Marleau, P.; Mattingly, J.; Mishra, M.; Moustafa, A.; Nattress, J.; Nishimura, K.; Pinto-Souza, B.; Steele, J.; Takahashi, E.; Ziock, K.

Abstract not provided.

Single Volume Scatter Camera: Optically Segmented Effort

Sweany, Melinda D.; Adamek, E.; Alhajaji, H.; Brown, James R.; Balathy, John; Brubaker, E.; Cabrera-Palmer, B.; Cates, J.C.B.; Dorril, R.; Druetzler, A.; Elam, J.; Febbraro, M.; Feng, Patrick L.; Folsom, Michael W.; Gabella, G.; Galindo-Tellez, A.; Goldblum, B.; Hausladen, P.; Kaneshige, N.; Keffe, Kevin; Laplace, T.A.; Maggi, Paul; Mane, A.; Manfredi, J.; Marleau, P.; Mattingly, J.; Mishra, M.; Moustafa, A.; Nattress, J.; Nishimura, K.; Pinto-Souza, B.; Steele, J.; Takahashi, E.; Ziock, K.

Abstract not provided.

Imaging Special Nuclear Material using a Handheld Dual Particle Imager

Scientific Reports

Steinberger, William M.; Ruch, Marc L.; Di Fulvio, Angela; Marleau, P.; Clarke, Shaun D.; Pozzi, Sara A.

A compact radiation imaging system capable of detecting, localizing, and characterizing special nuclear material (e.g. highly-enriched uranium, plutonium…) would be useful for national security missions involving inspection, emergency response, or war-fighters. Previously-designed radiation imaging systems have been large and bulky with significant portions of volume occupied by photomultiplier tubes (PMTs). The prototype imaging system presented here uses silicon photomultipliers (SiPMs) in place of PMTs because SiPMs are much more compact and operate at low power and voltage. The SiPMs are coupled to the ends of eight stilbene organic scintillators, which have an overall volume of 5.74 × 5.74 × 7.11 cm3. The prototype dual-particle imager’s capabilities were evaluated by performing measurements with a 252Cf source, a sphere of 4.5 kg of alpha-phase weapons-grade plutonium known as the BeRP ball, a 6 kg sphere of neptunium, and a canister of 3.4 kg of plutonium oxide (7% 240Pu and 93% 239Pu). These measurements demonstrate neutron spectroscopic capabilities, a neutron image resolution for a Watt spectrum of 9.65 ± 0.94° in the azimuthal direction and 22.59 ± 5.81° in the altitude direction, imaging of gamma rays using organic scintillators, and imaging of multiple sources in the same field of view.

More Details

CONFIDANTE Demonstration Prototype Report

Marleau, P.; Krentz-Wee, Rebecca E.

This report summarizes design optimization and performance evaluation studies for a new prototype CONFIDANTE (CONfirmation using a Fast-neutron Imaging Detector with Anti-image Null-positive Time Encoding) warhead confirmation system. It was found that a spherical mask geometry and a 2” diameter cylindrical central detector is expected to best discriminate between the parametrically varied source distributions that were evaluated. The optimized design as fabricated and its performance was evaluated in a series of laboratory measurements. The performance was in good agreement with the design studies, with demonstrated discrimination between objects with differences in scale on the order of 5 centimeters or better at 1 meter stand-off

More Details

The Single-Volume Scatter Camera

Manfredi, Juan; Adamek, Evan; Brown, Joshua; Brubaker, E.; Cabrera-Palmer, B.; Cates, Joshua; Dorrill, Ryan; Druetzler, Andrew; Elam, Jeff; Feng, Patrick L.; Folsom, Micah; Galindo-Tellez, Aline; Goldblum, Bethany; Hausladen, Paul; Kaneshige, Nathan; Keefe, Kevin P.; Laplace, Thibault; Learned, John; Mane, Anil; Marleau, P.; Mattingly, John; Mishra, Mudit; Moustafa, Ahmed; Nattress, Jason; Steele, J.; Sweany, Melinda D.; Weinfurther, Kyle J.; Ziock, Klaus-Peter

Abstract not provided.

Characterization of a silicon photo-multiplier array with summing board as a photo-multiplier tube replacement in organic scintillator assemblies

Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Sweany, Melinda D.; Marleau, P.; Allwork, C.; Kallenbach, G.; Hammon, Steven

We report on the energy, timing, and pulse-shape discrimination performance of cylindrical 5.08 cm diameter × 5.08 cm thick and 7.62 cm diameter × 7.62 cm thick trans-stilbene crystals read out with the passively summed output of three different commercial silicon photo-multiplier arrays. Our results indicate that using the summed output of an 8 × 8 array of SiPMs provides performance competitive with photo-multiplier tubes for many neutron imaging and correlated particle measurements. For a 5.08 cm diameter × 5.08 cm thick crystal read out with SensL's ArrayJ-60035_64P-PCB, which had the best overall properties, we measure the energy resolution as 17.8 ± 0.8% at 341 keVee (σ/E), the timing resolution in the 180–400 keVee range as 236 ± 61 ps (σ), and the pulse-shape discrimination figure-of-merit as 2.21 ± 0.03 in the 230–260 keVee energy range. For a 7.62 cm diameter × 7.62 cm thick crystal read out with SensL's ArrayJ-60035_64P-PCB, we measure the energy resolution as 21.9 ± 2.3% at 341 keVee, the timing resolution in the 180–400 keVee range as 518 ± 42 ps, and the pulse-shape discrimination figure-of-merit as 1.49 ± 0.01 in the 230–260 keVee energy range. These results enable many scintillator-based instruments to enjoy the size, robustness, and power benefits of silicon photo-multiplier arrays as replacement for the photo-multiplier tubes that are predominantly used today.

More Details

The single-volume scatter camera

Proceedings of SPIE - The International Society for Optical Engineering

Manfredi, Juan J.; Adamek, Evan; Brown, Joshua A.; Brubaker, E.; Cabrera-Palmer, B.; Cates, Joshua; Dorrill, Ryan; Druetzler, Andrew; Elam, Jeff; Feng, Patrick L.; Folsom, Micah; Galindo-Tellez, Aline; Goldblum, Bethany L.; Hausladen, Paul; Kaneshige, Nathan; Keefe, Kevin P.; Laplace, Thibault A.; Learned, John G.; Mane, Anil; Marleau, P.; Mattingly, John; Mishra, Mudit; Moustafa, Ahmed; Nattress, Jason; Steele, J.; Sweany, Melinda D.; Weinfurther, Kyle J.; Ziock, Klaus P.

The multi-institution Single-Volume Scatter Camera (SVSC) collaboration led by Sandia National Laboratories (SNL) is developing a compact, high-efficiency double-scatter neutron imaging system. Kinematic emission imaging of fission-energy neutrons can be used to detect, locate, and spatially characterize special nuclear material. Neutron-scatter cameras, analogous to Compton imagers for gamma ray detection, have a wide field of view, good event-by-event angular resolution, and spectral sensitivity. Existing systems, however, suffer from large size and/or poor efficiency. We are developing high-efficiency scatter cameras with small form factors by detecting both neutron scatters in a compact active volume. This effort requires development and characterization of individual system components, namely fast organic scintillators, photodetectors, electronics, and reconstruction algorithms. In this presentation, we will focus on characterization measurements of several SVSC candidate scintillators. The SVSC collaboration is investigating two system concepts: the monolithic design in which isotropically emitted photons are detected on the sides of the volume, and the optically segmented design in which scintillation light is channeled along scintillator bars to segmented photodetector readout. For each of these approaches, we will describe the construction and performance of prototype systems. We will conclude by summarizing lessons learned, comparing and contrasting the two system designs, and outlining plans for the next iteration of prototype design and construction.

More Details

Position and Timing Resolution Measurements ofOrganic-Glass scintillator bars for the OpticallySegmented Single-Volume Scatter Camera

Sweany, Melinda D.; Brown, Jason; Cabrera-Palmer, B.; Carlson, Joseph; Dorrill, R.; Druetzler, A.; Elam, J.; Febbraro, M.; Feng, Patrick L.; Folsom, Michael W.; Galino-Tellez, A.; Goldblum, B.; Hausladen, P.; Kaneshige, N.; Keffe, K.; Laplace, T.; Learned, J.; Mane, A.; Manfredi, Juan; Marleau, P.; Mattingly, J.; Mishra, M.; Moustafa, A.; Nattress, J.; Steele, J.; Weinfurther, K.; Ziock, K.

Abstract not provided.

Advanced Imaging Algorithms for Radiation Imaging Systems

Marleau, P.; Polack, Kyle; Pozzi, Sarah

Radiation-imaging devices are important to the nuclear security and safeguards communities due to their ability to detect and localize radioactive sources. Because of their low natural background, difficulty to shield, and unique association with SNM, fast-neutron imaging provides a promising means for the detection of SNM. To make these R&D systems useful for end-user applications, robust reconstruction and analysis algorithms must be developed that provide detailed information on the location, energy spectrum, and intervening material. To date, deconvolution, match filtering, and MLEM have been demonstrated. However, the information provided is limited to an approximate location of the source.

More Details

Design and Evaluation of a Pixelated PSD-capable Scintillator Detector with SiPM Readout

Sweany, Melinda D.; Marleau, P.; Hammon, Steven; Kallenbach, Gene; Polack, John K.

We present the detector response comparison between a 10x10 pixellated array of scintillator read out with Anger logic using four 2" Hamamatsu R7724-100 super bialkali photomultiplier tubes (PMT) and a custom Silicon photomultiplier (SiPM) board consisting of 100 C-series 6x6 mm SiPMs from SensL. An array of these pixellated detectors are currently used in the Neutron Coded Aperture (NCA) imaging system. The energy, timing and pulse shape discrimination response using both readout schemes are presented, along with an analysis of multiple scatter events occurring within the block. An evaluation of the impact of photodetector readout on the overall detection efficiency and imaging accuracy is presented.

More Details

Current status of an optically-segmented single-volume scatter camera for neutron imaging

Brown, Joshua; Brubaker, E.; Cabrera-Palmer, B.; Carlson, Joseph; Dorril, Ryan; Druetzler, Andrew; Elam, Jeff; Febbraro, Michael; Feng, Patrick L.; Folsom, Micah; Galino-Tellez, Aline; Goldblum, Bethany; Hausladen, Paul; Kaneshige, Nate; Keffe, Kevin; Laplace, Tibo; Learned, John; Mane, Anil; Manfredi, Juan; Marleau, P.; Mattingly, John; Mishra, Mudit; Moustafa, Ahmed; Nattress, Jason; Nishimura, Kurtis; Steele, J.; Sweany, Melinda D.; Ziock, Klaus

Abstract not provided.

Special Nuclear Material Detection and Monitoring by Environmental Activation Products Detection

Marleau, P.; Shinner, Matthew

Through a series of measurements with a high purity germanium detector, we have established that the past presence of neutron emitting material can be detected by the decay of activation products in aluminum containers, tungsten shielding, and concrete floors even several days after last exposure. The time since last exposure can also be estimated by the gamma-ray detection rate. These findings may lead to interesting new CONOPS in the detection of illicit SNM or the verification of the absence (or presence) of SNM containing objects in facilities and/or transit even after the material has been removed.

More Details

Characterization of a Silicon photo-multiplier summing breakout board for photo-multiplier tube replacement

Sweany, Melinda D.; Marleau, P.; Kallenbach, Gene A.

We present the relative timing and pulse-shape discrimination performance of a H1949-50 photomultiplier tube to SensL ArrayX-B0B6_64S coupled to a SensL ArrayC-60035-64P- PCB Silicon Photomultiplier array. The goal of this work is to enable the replacement of photomultiplier readout of scintillators with Silicon Photomultiplier devices, which are more robust and have higher particle detection efficiency. The report quantifies the degradation of these performance parameters using commercial off the shelf summing circuits, and motivates the development of an improved summing circuit: the pulse-shape descrimination figure-of-merit drops from 1.7 at 500 keVee to 1.4, and the timing resolution (σ) is 288 ps for the photomultiplier readout and approximately 1 ns for the Silicon Photomultiplier readout. A degradation of this size will have a large negative impact on any device that relies on timing coincidence or pulse-shape discrimination to detect neutron interactions, such as neutron kinematic imaging or multiplicity measurements.

More Details

Feasibility of Single-sided 3D elemental imaging

Sweany, Melinda D.; Gerling, Mark; Marleau, P.; Monterial, Mateusz

We present single-sided 3D image reconstruction and neutron spectrum of non-nuclear material interrogated with a deuterium-tritium neutron generator. The results presented here are a proof-of-principle of an existing technique previously used for nuclear material, applied to non-nuclear material. While we do see excess signatures over background, they do not have the expected form and are currently un-identified.

More Details

Source detection at 100 meter standoff with a time-encoded imaging system

Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Brennan, J.; Brubaker, E.; Gerling, Mark; Marleau, P.; Monterial, M.; Nowack, A.; Schuster, P.; Sturm, B.; Sweany, Melinda D.

We present the design, characterization, and testing of a laboratory prototype radiological search and localization system. The system, based on time-encoded imaging, uses the attenuation signature of neutrons in time, induced by the geometrical layout and motion of the system. We have demonstrated the ability to detect a ∼1mCi252Cf radiological source at 100m standoff with 90% detection efficiency and 10% false positives against background in 12min. This same detection efficiency is met at 15s for a 40m standoff, and 1.2s for a 20m standoff.

More Details

Position sensitivity within a bar of stilbene coupled to silicon photomultipliers

2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016

Ruch, Marc L.; Marleau, P.; Pozzi, Sara A.

A 6-mm by 6-mm by 50-mm bar of stilbene was coupled on both ends to silicon photomultipliers (SiPMs) to assess the detector's position sensitivity to interactions throughout the bar. A Na-22 gamma ray source was collimated with a pair of lead bricks to produce a source beam that was used to irradiate five positions along the length of the bar. A logarithmic relationship between the ratio of the pulse heights obtained from the two SiPMs and the position of the collimated source was established. The standard deviation of the distribution of ratios from each measurement was propagated through the functional form to determine position resolution. The position resolution along the length of the bar was determined to have an average value of 4.9 mm.

More Details

Null-hypothesis testing using distance metrics for verification of arms-control treaties

2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016

Khalil, Mohammad; Brubaker, E.; Hilton, Nathan R.; Kupinski, Matthew A.; Macgahan, Christopher J.; Marleau, P.

We investigate the feasibility of constructing a data-driven distance metric for use in null-hypothesis testing in the context of arms-control treaty verification. The distance metric is used in testing the hypothesis that the available data are representative of a certain object or otherwise, as opposed to binary-classification tasks studied previously. The metric, being of strictly quadratic form, is essentially computed using projections of the data onto a set of optimal vectors. These projections can be accumulated in list mode. The relatively low number of projections hampers the possible reconstruction of the object and subsequently the access to sensitive information. The projection vectors that channelize the data are optimal in capturing the Mahalanobis squared distance of the data associated with a given object under varying nuisance parameters. The vectors are also chosen such that the resulting metric is insensitive to the difference between the trusted object and another object that is deemed to contain sensitive information. Data used in this study were generated using the GEANT4 toolkit to model gamma transport using a Monte Carlo method. For numerical illustration, the methodology is applied to synthetic data obtained using custom models for plutonium inspection objects. The resulting metric based on a relatively low number of channels shows moderate agreement with the Mahalanobis distance metric for the trusted object but enabling a capability to obscure sensitive information.

More Details

Enabling Explosives and Contraband Detection

Sweany, Melinda D.; Marleau, P.; Monterial, M.

We present the design and performance of a proof-of-concept 32 channel material identification system. Our system is based on the energy-dependent attenuation of fast neutrons for four elements: hydrogen, carbon, nitrogen and oxygen. We describe a new approach to obtaining a broad range of neutron energies to probe a sample, as well as our technique for reconstructing the molar densities within a sample. The system's performance as a function of time-of-flight energy resolution is explored using a Geant4-based Monte Carlo. Our results indicate that, with the expected detector response of our system, we will be able to determine the molar density of all four elements to within a 20-30% accuracy in a two hour scan time. In many cases this error is systematically low, thus the ratio between elements is more accurate. This degree of accuracy is enough to distinguish, for example, a sample of water from a sample of pure hydrogen peroxide: the ratio of oxygen to hydrogen is reconstructed to within 8 0.5% of the true value. Finally, with future algorithm development that accounts for backgrounds caused by scattering within the sample itself, the accuracy of molar densities, not ratios, may improve to the 5-10% level for a two hour scan time. Experimental performance was evaluated with various thicknesses of polyethylene. The detector response in terms of energy, particle identification, and timing are presented as well.

More Details

Taking Advantage of Disorder: Small-Molecule Organic Glasses for Radiation Detection and Particle Discrimination

Journal of the American Chemical Society

Carlson, Joseph; Marleau, P.; Zarkesh, Ryan A.; Feng, Patrick L.

A series of fluorescent silyl-fluorene molecules were synthesized and studied with respect to their photophysical properties and response toward ionizing neutron and gamma-ray radiation. Optically transparent and stable organic glasses were prepared from these materials using a bulk melt-casting procedure. The prepared organic glass monoliths provided fluorescence quantum yields and radiation detection properties exceeding the highest-performing benchmark materials such as solution-grown trans-stilbene crystals. Co-melts based on blends of two different glass-forming compounds were prepared with the goal of enhancing the stability of the amorphous state. Accelerated aging experiments on co-melt mixtures ranging from 0% to 100% of each component indicated improved resistance to recrystallization in the glass blends, able to remain fully amorphous for >1 month at 60 °C. Secondary dopants comprising singlet fluorophores or iridium organometallic compounds provided further improved detection efficiency, as evaluated by light yield and neutron/gamma particle discrimination measurements. Optimized singlet and triplet doping levels were determined to be 0.05 wt % 1,4-bis(2-methylstyryl)benzene singlet fluorophore and 0.28 wt % Ir3+, respectively.

More Details

Single-View 3-D Reconstruction of Correlated Gamma-Neutron Sources

IEEE Transactions on Nuclear Science

Monterial, M.; Marleau, P.; Pozzi, Sara A.

We describe a new method of 3-D image reconstruction of neutron sources that emit correlated gammas (e.g., Cf-252, Am-Be). This category includes a vast majority of neutron sources important in nuclear threat search, safeguards and non-proliferation. Rather than requiring multiple views of the source this technique relies on the source's intrinsic property of coincidence gamma and neutron emission. As a result, only a single-view measurement of the source is required to perform the 3-D reconstruction. In principle, any scatter camera sensitive to gammas and neutrons with adequate timing and interaction location resolution can perform this reconstruction. Using a neutron double scatter technique, we can calculate a conical surface of possible source locations. By including the time to a correlated gamma we further constrain the source location in three-dimensions by solving for the source-to-detector distance along the surface of the cone. As a proof of concept we applied these reconstruction techniques on measurements taken with the Mobile Imager of Neutrons for Emergency Responders (MINER). Two Cf-252 sources measured at 50 and 60 cm from the center of the detector were resolved in their varying depth with average radial distance relative resolution of 26%. To demonstrate the technique's potential with an optimized system we simulated the measurement in MCNPX-PoliMi assuming timing resolution of 200 ps (from 2 ns in the current system) and source interaction location resolution of 5 mm (from 3 cm). These simulated improvements in scatter camera performance resulted in radial distance relative resolution decreasing to an average of 11%.

More Details

Multiplication and Presence of Shielding Material from Time-Correlated Pulse-Height Measurements of Subcritical Plutonium Assemblies

Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Monterial, M.; Marleau, P.; Paff, Marc; Clarke, Shaun; Pozzi, Sara

We present the results from the first measurements of the Time-Correlated Pulse-Height (TCPH) distributions from 4.5 kg sphere of α-phase weapons-grade plutonium metal in five configurations: bare, reflected by 1.27 cm and 2.54 cm of tungsten, and 2.54 cm and 7.62 cm of polyethylene. A new method for characterizing source multiplication and shielding configuration is also demonstrated. The method relies on solving for the underlying fission chain timing distribution that drives the spreading of the measured TCPH distribution. We found that a gamma distribution fits the fission chain timing distribution well and that the fit parameters correlate with both multiplication (rate parameter) and shielding material types (shape parameter). The source-to-detector distance was another free parameter that we were able to optimize, and proved to be the most well constrained parameter. MCNPX-PoliMi simulations were used to complement the measurements and help illustrate trends in these parameters and their relation to multiplication and the amount and type of material coupled to the subcritical assembly.

More Details

Linear models to perform treaty verification tasks for enhanced information security

Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Macgahan, Christopher J.; Kupinski, Matthew A.; Brubaker, E.; Hilton, Nathan R.; Marleau, P.

Linear mathematical models were applied to binary-discrimination tasks relevant to arms control verification measurements in which a host party wishes to convince a monitoring party that an item is or is not treaty accountable. These models process data in list-mode format and can compensate for the presence of variability in the source, such as uncertain object orientation and location. The Hotelling observer applies an optimal set of weights to binned detector data, yielding a test statistic that is thresholded to make a decision. The channelized Hotelling observer applies a channelizing matrix to the vectorized data, resulting in a lower dimensional vector available to the monitor to make decisions. We demonstrate how incorporating additional terms in this channelizing-matrix optimization offers benefits for treaty verification. We present two methods to increase shared information and trust between the host and monitor. The first method penalizes individual channel performance in order to maximize the information available to the monitor while maintaining optimal performance. Second, we present a method that penalizes predefined sensitive information while maintaining the capability to discriminate between binary choices. Data used in this study was generated using Monte Carlo simulations for fission neutrons, accomplished with the GEANT4 toolkit. Custom models for plutonium inspection objects were measured in simulation by a radiation imaging system. Model performance was evaluated and presented using the area under the receiver operating characteristic curve.

More Details

Investigation into Practical Implementations of a Zero Knowledge Protocol

Marleau, P.; Krentz-Wee, Rebecca E.

In recent years, the concept of Zero Knowledge Protocols (ZKP) as a useful approach to nuclear warhead verification has become increasingly popular. Several implementations of ZKP have been proposed, driving technology development toward proof of concept demonstrations. Whereas proposed implementations seem to fall within the general class of template-based techniques, all physical implementations of ZKPs proposed to date have a complication: once the instrumentation is prepared, it is no longer authenticatable; the instrument physically contains sensitive information. In this work we explore three different concepts that may offer more authenticatable and practical ZKP implementations and evaluate the sensitive information that may be at risk when doing so: sharing a subset of detector counts in a preloaded image (with spatial information removed), real-time image subtraction, and a new concept, CONfirmation using a Fast-neutron Imaging Detector with Anti-image NULL-positive Time Encoding (CONFIDANTE). CONFIDANTE promises to offer an almost ideal implementation of ZKP: a positive result is indicated by a constant rate at all times enabling the monitoring party the possibility of full access to the instrument before, during, and after confirmation. A prototype of CONFIDANTE was designed, built, and its performance evaluated in a series of measurements of several objects including a set of plutonium dioxide Hemispheres. Very encouraging results proving feasibility are presented. 1 Rebecca is currently a graduate student in Nuclear Engineering at UC Berkeley

More Details

Magnetic Induction Sensors for Detecting Anomalous Shielding of Radiological and Nuclear Materials: A Feasibility Study

Marleau, P.; Antonio, Dolores; Brennan, J.; Helm, Jonathan I.; Shokair, Isaac R.

This study examined a concept for improving the nation's ability to detect unauthorized transport of radiological and nuclear material that involves detecting not the radiological or nuclear material itself, but rather the anomalous presence of materials, such as lead and tungsten, typically used to shield such illicit materials from detection. Specifically, the project studied a potentially inexpensive, non-intrusive, and fast method of detecting anomalous shielding: use of magnetic induction sensors to measure currents induced in conductors by a driver coil. The first phase of this work, documented in this report, identified the signatures of materials of interest, assessed the usefulness of measured signatures for discrimination between materials, and then benchmarked models and calculations. The next task involved assessing the strength of these signatures when the materials of interest were enclosed within other materials, such as aluminum and steel, of various thicknesses. A final task mimicked a real-world scenario by testing the ability to detect material signatures of interest at a scale of a vehicle or cargo vessel against a cluttered backdrop, with and without the shielding of another material, such as aluminum or steel. This final task raised doubts regarding whether this detection scheme will be useful under real-world conditions.

More Details

Measurement of High-Energy Neutron Flux above Ground Utilizing a Spallation Based Multiplicity Technique

IEEE Transactions on Nuclear Science

Marleau, P.; Roecker, Caleb; Bernstein, Adam; Vetter, Kai

Cosmogenic high-energy neutrons are a ubiquitous, difficult to shield, poorly measured background. Above ground the high-energy neutron energy-dependent flux has been measured, with significantly varying results. Below ground, high-energy neutron fluxes are largely unmeasured. Here we present a reconstruction algorithm to unfold the incident neutron energy-dependent flux measured using the Multiplicity and Recoil Spectrometer (MARS), simulated test cases to verify the algorithm, and provide a new measurement of the above ground high-energy neutron energy-dependent flux with a detailed systematic uncertainty analysis. Uncertainty estimates are provided based upon the measurement statistics, the incident angular distribution, the surrounding environment of the Monte Carlo model, and the MARS triggering efficiency. Quantified systematic uncertainty is dominated by the assumed incident neutron angular distribution and surrounding environment of the Monte Carlo model. The energy-dependent neutron flux between 90 MeV and 400 MeV is reported. Between 90 MeV and 250 MeV the MARS results are comparable to previous Bonner sphere measurements. Over the total energy regime measured, the MARS result are located within the span of previous measurements. These results demonstrate the feasibility of future below ground measurements with MARS.

More Details
Results 1–100 of 242
Results 1–100 of 242