A Method for Correcting Frequency and RoCoF Estimates of Power System Signals with Phase Steps
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
IEEE Transactions on Power Systems
This paper describes the design and implementation of a proof-of-concept Pacific dc Intertie (PDCI) wide area damping controller and includes system test results on the North American Western Interconnection (WI). To damp inter-area oscillations, the controller modulates the power transfer of the PDCI, a ±500 kV dc transmission line in the WI. The control system utilizes real-time phasor measurement unit (PMU) feedback to construct a commanded power signal which is added to the scheduled power flow for the PDCI. After years of design, simulations, and development, this controller has been implemented in hardware and successfully tested in both open and closed-loop operation. The most important design specifications were safe, reliable performance, no degradation of any system modes in any circumstances, and improve damping to the controllable modes in the WI. The main finding is that the controller adds significant damping to the modes of the WI and does not adversely affect the system response in any of the test cases. The primary contribution of this paper, to the state of the art research, is the design methods and test results of the first North American real-time control system that uses wide area PMU feedback.
IEEE Power and Energy Society General Meeting
This paper explores the revenue potential for electric storage resources (ESRs), also referred to as electrical energy storage, in the Southwest Power Pool Integrated Marketplace. In particular, opportunities in the day-ahead market with the energy and frequency regulation products are considered. The revenue maximization problem is formulated as a linear program model, where an ESR seeks to maximize its revenue through the available revenue streams. The ESR has perfect foresight of historical prices and determines the optimal policy accordingly. A case study using FY2018 data shows that frequency regulation services are the most lucrative for revenue potential. This paper also explores different methods of using area control error data to infer the regulation control signal and the consequent effect on the optimization. Finally, the paper conducts a sensitivity analysis of ESR payback period to energy capacity and power rating.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
This report presents a complete listing, as of May 2019, of the damping controller (DCON) project accomplishments including a project overview, project innovations, awards, patent application, journal papers, conference papers, project reports, and project presentations. The purpose of the DCON is to mitigate inter-area oscillations in the WI by active improvement of oscillatory mode damping using phasor measurement unit (PMU) feedback to modulate power flow in the PDCI. The DCON project is the result of a collaboration between Sandia National Laboratories (SNL), Montana Technological University (MTU), Bonneville Power Administration (BPA), and the Department of Energy Office of Electricity (DOE-OE).
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Proceedings of the Annual Hawaii International Conference on System Sciences
This paper analyzes the effect of wind turbine integration (WT) on the inter-area oscillation mode of a test two-area power system. The paper uses a root-locus based design method to propose a pair of controllers to provide damping to the inter-area mode of the system. The controllers are selected from the best combination of feedback signal and WT control action. One of the controllers uses the active power control part of the WT while the other uses the reactive power part. The paper analyzes the impact that increases on the transmission line connecting the WT to the system have on the controllers' performance. Time domain simulations are provided to evaluate the effectiveness of the controllers under different conditions.
IEEE Power and Energy Society General Meeting
This paper focuses on a transmission system with a high penetration of converter-interfaced generators participating in its primary frequency regulation. In particular, the effects on system stability of widespread misconfiguration of frequency regulation schemes are considered. Failures in three separate primary frequency control schemes are analyzed by means of time domain simulations where control action was inverted by, for example, negating controller gain. The results indicate that in all cases the frequency response of the system is greatly deteriorated and, in multiple scenarios, the system loses synchronism. It is also shown that including limits to the control action can mitigate the deleterious effects of inverted control configurations.