Publications

21 Results
Skip to search filters

Understanding the Implications of a LINAC's Microstructure on Devices and Photocurrent Models

IEEE Transactions on Nuclear Science

McLain, Michael L.; McDonald, Joseph K.; Hembree, Charles E.; Sheridan, Timothy J.; Weingartner, Thomas A.; Dodd, Paul E.; Shaneyfelt, Marty R.; Hartman, Elmer F.; Black, Dolores A.

The effect of a linear accelerator's (LINAC's) microstructure (i.e., train of narrow pulses) on devices and the associated transient photocurrent models are investigated. The data indicate that the photocurrent response of Si-based RF bipolar junction transistors and RF p-i-n diodes is considerably higher when taking into account the microstructure effects. Similarly, the response of diamond, SiO2, and GaAs photoconductive detectors (standard radiation diagnostics) is higher when taking into account the microstructure. This has obvious hardness assurance implications when assessing the transient response of devices because the measured photocurrent and dose rate levels could be underestimated if microstructure effects are not captured. Indeed, the rate the energy is deposited in a material during the microstructure peaks is much higher than the filtered rate which is traditionally measured. In addition, photocurrent models developed with filtered LINAC data may be inherently inaccurate if a device is able to respond to the microstructure.

More Details

Prompt radiation-induced conductivity in polyurethane foam and glass microballoons

Hartman, Elmer F.; Zarick, Thomas A.; Sheridan, Timothy J.

We performed measurements and analyses of the prompt radiation-induced conductivity (RIC) in thin samples of polyurethane foam and glass microballoon foam at the Little Mountain Medusa LINAC facility in Ogden, UT. The RIC coefficient was non-linear with dose rate for polyurethane foam; however, typical values at 1E11 rad(si)/s dose rate was measured as 0.8E-11 mho/m/rad/s for 5 lb./cu ft. foam and 0.3E-11 mho/m/rad/s for 10 lb./cu ft. density polyurethane foam. For encapsulated glass microballoons (GMB) the RIC coefficient was approximately 1E-15 mho/m/rad/s and was not a strong function of dose rate.

More Details

Measurements of Prompt Radiation-Induced Conductivity of Pyralux®

Hartman, Elmer F.; Zarick, Thomas A.; McLain, Michael L.; Sheridan, Timothy J.

In this report, measurements of the prompt radiation-induced conductivity (RIC) in 3 mil samples of Pyralux® are presented as a function of dose rate, pulse width, and applied bias. The experiments were conducted with the Medusa linear accelerator (LINAC) located at the Little Mountain Test Facility (LMTF) near Ogden, UT. The nominal electron energy for the LINAC is 20 MeV. Prompt conduction current data were obtained for dose rates ranging from ~2 x 109 rad(Si)/s to ~1.1 x 1011 rad(Si)/s and for nominal pulse widths of 50 ns and 500 ns. At a given dose rate, the applied bias across the samples was stepped between -1500 V and 1500 V. Calculated values of the prompt RIC varied between 1.39x10-8 Ω-1 · m-1 and 2.67x10-7 Ω-1 · m-1 and the prompt RIC coefficient varied between 1.25x10-18 Ω-1 · m-1/(rad/s) and 1.93x10-17 Ω-1 · m-1/(rad/s).

More Details

Measurements of prompt radiation induced conductivity in Teflon (PTFE)

Hartman, Elmer F.; Zarick, Thomas A.; Sheridan, Timothy J.

We performed measurements of the prompt radiation induced conductivity (RIC) in thin samples of Teflon (PTFE) at the Little Mountain Medusa LINAC facility in Ogden, UT. Three mil (76.2 microns) samples were irradiated with a 0.5 %CE%BCs pulse of 20 MeV electrons, yielding dose rates of 1E9 to 1E11 rad/s. We applied variable potentials up to 2 kV across the samples and measured the prompt conduction current. Details of the experimental apparatus and analysis are reported in this report on prompt RIC in Teflon.

More Details

Measurements of prompt radiation induced conductivity of alumina and sapphire

Hartman, Elmer F.; Zarick, Thomas A.; Sheridan, Timothy J.

We performed measurements of the prompt radiation induced conductivity in thin samples of Alumina and Sapphire at the Little Mountain Medusa LINAC facility in Ogden, UT. Five mil thick samples were irradiated with pulses of 20 MeV electrons, yielding dose rates of 1E7 to 1E9 rad/s. We applied variable potentials up to 1 kV across the samples and measured the prompt conduction current. Analysis rendered prompt conductivity coefficients between 1E10 and 1E9 mho/m/(rad/s), depending on the dose rate and the pulse width for Alumina and 1E7 to 6E7 mho/m/(rad/s) for Sapphire.

More Details

Physics of intense, high energy radiation effects

Hjalmarson, Harold P.; Magyar, Rudolph J.; Crozier, Paul C.; Hartman, Elmer F.

This document summarizes the work done in our three-year LDRD project titled 'Physics of Intense, High Energy Radiation Effects.' This LDRD is focused on electrical effects of ionizing radiation at high dose-rates. One major thrust throughout the project has been the radiation-induced conductivity (RIC) produced by the ionizing radiation. Another important consideration has been the electrical effect of dose-enhanced radiation. This transient effect can produce an electromagnetic pulse (EMP). The unifying theme of the project has been the dielectric function. This quantity contains much of the physics covered in this project. For example, the work on transient electrical effects in radiation-induced conductivity (RIC) has been a key focus for the work on the EMP effects. This physics in contained in the dielectric function, which can also be expressed as a conductivity. The transient defects created during a radiation event are also contained, in principle. The energy loss lead the hot electrons and holes is given by the stopping power of ionizing radiation. This information is given by the inverse dielectric function. Finally, the short time atomistic phenomena caused by ionizing radiation can also be considered to be contained within the dielectric function. During the LDRD, meetings about the work were held every week. These discussions involved theorists, experimentalists and engineers. These discussions branched out into the work done in other projects. For example, the work on EMP effects had influence on another project focused on such phenomena in gases. Furthermore, the physics of radiation detectors and radiation dosimeters was often discussed, and these discussions had impact on related projects. Some LDRD-related documents are now stored on a sharepoint site (https://sharepoint.sandia.gov/sites/LDRD-REMS/default.aspx). In the remainder of this document the work is described in catergories but there is much overlap between the atomistic calculations, the continuum calculations and the experiments.

More Details

Measurements of prompt radiation induced conductivity of Kapton

Hartman, Elmer F.; Zarick, Thomas A.; Sheridan, Timothy J.

We performed measurements of the prompt radiation induced conductivity in thin samples of Kapton (polyimide) at the Little Mountain Medusa LINAC facility in Ogden, UT. Three mil samples were irradiated with a 0.5 {mu}s pulse of 20 MeV electrons, yielding dose rates of 1E9 to 1E10 rad/s. We applied variable potentials up to 2 kV across the samples and measured the prompt conduction current. Analysis rendered prompt conductivity coefficients between 6E-17 and 2E-16 mhos/m per rad/s, depending on the dose rate and the pulse width.

More Details

Dosimetry experiments at the MEDUSA Facility (Little Mountain)

Harper-Slaboszewicz, V.H.; Hartman, Elmer F.; Shaneyfelt, Marty R.; Schwank, James R.; Sheridan, Timothy J.

A series of experiments on the MEDUSA linear accelerator radiation test facility were performed to evaluate the difference in dose measured using different methods. Significant differences in dosimeter-measured radiation dose were observed for the different dosimeter types for the same radiation environments, and the results are compared and discussed in this report.

More Details

A test protocol to screen capacitors for radiation-induced charge loss

Hartman, Elmer F.; Zarick, Thomas A.

This report presents a test protocol for screening capacitors dielectrics for charge loss due to ionizing radiation. The test protocol minimizes experimental error and provides a test method that allows comparisons of different dielectric types if exposed to the same environment and if the same experimental technique is used. The test acceptance or screening method is fully described in this report. A discussion of technical issues and possible errors and uncertainties is included in this report also.

More Details

Spectral unfolds of PITHON Flash X-ray source

Hartman, Elmer F.; Zarick, Thomas A.; Sheridan, Timothy J.

Using a differential absorption spectrometer we obtained experimental spectral information for the PITHON Flash X-ray Machine located in San Leandro, California at L-3 Communications. Spectral information we obtained pertained to the 200 keV to 800 keV endpoint operation of PITHON. We also obtained data on the temporal behavior of high energy and low energy spectral content.

More Details
21 Results
21 Results