Publications

Results 1–50 of 189

Search results

Jump to search filters

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

Journal of Instrumentation

Balajthy, Jon A.; Brubaker, E.; Cabrera-Palmer, B.; Steele, J.; Hausladen, P.; Cates, J.; Goldblum, B.; Keefe, K.; Brown, J.; Folsom, M.; Nattress, J.; Negut, V.; Nishimura, K.; Ziock, K.

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. We calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

More Details

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Physics in Medicine and Biology

Cates, Joshua W.; Choong, Woon S.; Brubaker, E.

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

More Details

ASIC Scoping Study Final Report

Brubaker, E.; Sweany, Melinda D.; Tiano, Elicia K.O.; Becker, Eric; Fabris, Lorenzo; Grace, Carl; Hausladen, Paul A.; Johnson, Jyothis; Matta, James T.; Rescia, Sergio; Rose Jr., Paul B.; Wood, Lynn; Kay, Randolph R.

This report documents the results and findings of a one-year scoping study investigating multichannel readout application specific integrated circuits (ASICs) for interfacing to, and processing data from, silicon photomultiplier (SiPM) arrays. We document ASIC desired and required specifications for four applications supporting national security mission areas: neutron radiography, associated particle imaging, and two versions of kinematic neutron imaging cameras. While each application has a few unique requirements that stress capability, there is generally good agreement among most. Two recently developed ASIC devices were evaluated in a system-like configuration by interfacing these to scintillator crystals exposed to gamma and neutron sources. The 64-channel ORNL device delivered functional capability while meeting most mission requirements for neutron radiography. The Nalu Scientific device, a 32-channel full waveform digitizer, did not demonstrate reliable neutron / gamma separation but it is unclear if this was an ASIC issue or problems with test setup or firmware. A literature survey of other commercial and academic ASICs was undertaken to with the conclusion that existing devices do not meet all requirements.

More Details

Intra-class data augmentation with deep generative models of threat objects in baggage radiographs

Proceedings of SPIE - The International Society for Optical Engineering

Komkov, Heidi B.; Marshall, Matthew; Brubaker, E.

Despite state-of-the-art deep learning-based computer vision models achieving high accuracy on object recognition tasks, x-ray screening of baggage at checkpoints is largely performed by hand. Part of the challenge in automation of this task is the relatively small amount of available labeled training data. Furthermore, realistic threat objects may have forms or orientations that do not appear in any training data, and radiographs suffer from high amounts of occlusion. Using deep generative models, we explore data augmentation techniques to expand the intra-class variation of threat objects synthetically injected into baggage radiographs using openly available baggage x-ray datasets. We also benchmark the performance of object detection algorithms on raw and augmented data.

More Details

Intra-class data augmentation with deep generative models of threat objects in baggage radiographs

Proceedings of SPIE - The International Society for Optical Engineering

Komkov, Heidi B.; Marshall, Matthew; Brubaker, E.

Despite state-of-the-art deep learning-based computer vision models achieving high accuracy on object recognition tasks, x-ray screening of baggage at checkpoints is largely performed by hand. Part of the challenge in automation of this task is the relatively small amount of available labeled training data. Furthermore, realistic threat objects may have forms or orientations that do not appear in any training data, and radiographs suffer from high amounts of occlusion. Using deep generative models, we explore data augmentation techniques to expand the intra-class variation of threat objects synthetically injected into baggage radiographs using openly available baggage x-ray datasets. We also benchmark the performance of object detection algorithms on raw and augmented data.

More Details

Modeling ionization quenching in organic scintillators

Materials Advances

Laplace, Thibault A.; Goldblum, Bethany L.; Brown, Joshua A.; Leblanc, Glenn; Li, Tianyue; Manfredi, Juan J.; Brubaker, E.

Recoil nuclei produce high ionization and excitation densities in organic scintillators leading to reduced light yield via ionization quenching. To improve understanding of the relationship between organic scintillator specific luminescence and the characteristics of the recoil particle, this work evaluates proton and carbon light yield data using ionization quenching models over an energy range of tens of keV to several MeV for protons and 1-5 MeV for carbon ions. Previously-measured proton and carbon light yield data were examined for a variety of commercial and novel organic scintillating media: EJ-309, a liquid with pulse shape discrimination (PSD) properties; EJ-204, a fast plastic; EJ-276, a PSD-capable plastic; and a custom organic glass scintillator developed by Sandia National Laboratories. The canonical model of Birks did not adequately describe the ionization quenching behavior. Models proposed by Yoshida et al. and Voltz et al. provided a reasonable description of the proton light yield of a variety of organic scintillators over a broad energy range, but additional work is needed to extend the models to carbon ions. The impact of stopping power data was also investigated by comparing model predictions using SRIM and PSTAR/MSTAR libraries, and the results show a significant discrepancy for carbon ions. This work enhances understanding of ionization quenching and facilitates the accurate modeling of scintillator-based neutron detection systems relevant for medical physics, nuclear security and nonproliferation, and basic science studies.

More Details

Design and Characterization of an Optically Segmented Single Volume Scatter Camera Module

IEEE Transactions on Nuclear Science

Keefe, Kevin; Alhajaji, Hassam; Brubaker, E.; Druetzler, Andrew; Learned, John; Maggi, Paul; Manfredi, Juan J.; Nishimura, Kurtis; Souza, Bejamin P.; Steele, J.; Sweany, Melinda D.; Takahashi, Eric

The optically segmented single volume scatter camera (OS-SVSC) aims to image neutron sources for nuclear nonproliferation applications using the kinematic reconstruction of elastic double-scatter events. We report on the design, construction, and calibration of one module of a new prototype. The module includes 16 EJ-204 organic plastic scintillating bars individually wrapped in Teflon tape, each measuring 0.5 {\mathrm {cm}}\times 0.5 {\mathrm {cm}}\times 20 {\mathrm {cm}}. The scintillator array is coupled to two custom silicon photomultiplier (SiPM) boards consisting of a 2\times 8 array of SensL J-Series-60035 SiPMs, which are read out by a custom 16 channel DRS4 based digitizer board. The electrical crosstalk between SiPMs within the electronics chain is measured as 0.76\% \,\pm \,0.11\% among all 16 channels. We report the detector response of one module including interaction position, time, and energy, using two different optical coupling materials: EJ-560 silicone rubber optical coupling pads and EJ-550 optical coupling grease. We present results in terms of the overall mean and standard deviation of the z -position reconstruction and interaction time resolutions for all 16 bars in the module. We observed the 1\sigma z -position resolution for gamma interactions in the 0.3-0.4 MeVee range to be 2.24 cm ± 1.10 cm and 1.45 cm ± 0.19 cm for silicone optical coupling pad and optical grease, respectively. The observed 1\sigma interaction time resolution is 265 ps ± 29 ps and 235 ps ± 10 ps for silicone optical coupling pad and optical grease, respectively.

More Details

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Sensors

Cates, Joshua W.; Steele, J.; Balajthy, Jon A.; Negut, Victor; Hausladen, Paul; Ziock, Klaus; Brubaker, E.

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

More Details

Simultaneous measurement of organic scintillator response to carbon and proton recoils

Physical Review C

Laplace, T.A.; Goldblum, B.L.; Manfredi, J.J.; Brown, J.A.; Bleuel, D.L.; Brand, C.A.; Gabella, G.; Gordon, J.; Brubaker, E.

Background: Organic scintillators are widely used for neutron detection in both basic nuclear physics and applications. While the proton light yield of organic scintillators has been extensively studied, measurements of the light yield from neutron interactions with carbon nuclei are scarce. Purpose: Demonstrate a new approach for the simultaneous measurement of the proton and carbon light yield of organic scintillators. Provide new carbon light yield data for the EJ-309 liquid and EJ-204 plastic organic scintillators. Method: A 33-MeV H+2 beam from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory was impinged upon a 3-mm-thick Be target to produce a high-flux, broad-spectrum neutron beam. The double time-of-flight technique was extended to simultaneously measure the proton and carbon light yields of the organic scintillators, wherein the light output associated with the recoil particle was determined using np and nC elastic scattering kinematics. Results: The proton and carbon light yield relations of the EJ-309 liquid and EJ-204 plastic organic scintillators were measured over a recoil energy range of approximately 0.3 to 1 MeV and 2 to 5 MeV, respectively, for EJ-309, and 0.2 to 0.5 MeV and 1 to 4 MeV, respectively, for EJ-204. Conclusions: These data provide new insight into the ionization quenching effect in organic scintillators and key input for simulation of the response of organic scintillators for both basic science and a broad range of applications.

More Details

Open Radiation Monitoring: Conceptual System Design

Polack, John K.; Brubaker, E.; Hamel, Michael C.; Kiff, Scott; Marleau, P.; Maierhafer, Daniel; Padilla, Eduardo A.; Weber, Thomas M.

The Open Radiation Monitoring (ORM) Project seeks to develop and demonstrate a modular radiation detection architecture designed specifically for use in arms control treaty verification (ACTV) applications that will facilitate rapid development of trusted systems to meet the needs of potential future treaties. Development of trusted systems to support potential future treaties is a complex and costly endeavor that typically results in a purpose-built system designed to perform one specific task. The majority of prior trusted system development efforts have relied on the use of commercial embedded computers or microprocessors to control the system and process the acquired data. These processors are complex, making authentication and certification of measurement systems and collected data challenging and time consuming. We believe that a modular architecture can be used to reduce more complex systems to a series of single-purpose building blocks that could be used to implement a variety of detection modalities with shared functionalities. With proper design, the functionality of individual modules can be confirmed through simple input/output testing, thereby facilitating equipment inspection and in turn building trust in the equipment by all treaty parties. Furthermore, a modular architecture can be used to control data flow within the measurement system, reducing the risk of "hidden switches" and constraining the amount of sensitive information that could potentially be inadvertently leaked. This report documents a conceptual modular system architecture that is designed to facilitate inspection in an effort to reduce overall authentication and certification burden. As of publication, this architecture remains in a conceptual phase and additional funding is required to prove out the utility of a modular architecture and test the assumptions used to rationalize the design.

More Details

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

Journal of Instrumentation

Galindo-Tellez, A.; Keefe, Kevin P.; Adamek, E.; Brubaker, E.; Crow, B.; Dorrill, R.; Druetzler, A.; Felix, C.J.; Kaneshige, N.; Learned, J.G.; Manfredi, J.J.; Nishimura, K.; Souza, B.P.; Schoen, D.; Sweany, Melinda D.

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5 mm × 5 mm × 200 mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6 mm × 6 mm J-Series sensors arranged in an 8 × 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector’s mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 30 ps to 90 ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22Na and 90Sr, respectively, reporting an average resolution of (12.07 ± 0.03) mm for energy depositions between 900 keVee and 1000 keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of (14.86 ± 0.29) mm for depositions between 900 keVee and 1000 keVee. The coincident time resolution reported between pairs of bars measured up to 400 ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

More Details

Deployment of a double scatter system for directional detection of background neutron radiation

Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Glick, Adam; Brubaker, E.; Cabrera-Palmer, B.; Gerling, Mark; Quiter, Brian J.; Vetter, Kai

The detection of special nuclear materials (SNM) requires the understanding of nuclear signatures that allow the discrimination against background. In particular, understanding neutron background characteristics such as count rates and energies and their correlations with environmental conditions and surroundings of measurement locations is important in enhancing SNM detection capabilities. The Mobile Imager of Neutrons for Emergency Responders (MINER) was deployed for 8 weeks in downtown San Francisco (CA) to study such neutron background characteristics in an urban environment. Of specific interest was the investigation of the impact of surrounding buildings on the neutron background count rates and to answer the question whether buildings act as absorber of neutrons or as sources via the so-called ship effect. MINER consists of 16 liquid scintillator detector elements and can be operated as a neutron spectrometer, as a neutron imager, or simply as a counter of fast neutrons. As expected, the neutron background rate was found to be inversely proportional to the atmospheric pressure. In the energy range where MINER is most sensitive, approximately 1–10 MeV, it was found that the shape of the detected background spectrum is similar to that of a detected fission spectrum, indicating the limited discrimination power of the neutron energy. The similarities between the detected background neutron spectrum and fission sources makes it difficult to discriminate SNM from background based solely on the energies observed. The images produced using maximum likelihood expectation maximization revealed that neutrons preferentially are coming from areas in the environment that have open sky, indicating that the surrounding buildings act as absorbers of neutrons rather than sources as expected by the ship effect. The inherent properties of a neutron scatter camera limit the achievable image quality and the effective deployment to systematically map neutron background signatures due to the low count rate.

More Details

Single Volume Scatter Camera: Optically Segmented Effort

Sweany, Melinda D.; Adamek, E.; Alhajaji, H.; Brown, James R.; Balathy, John; Brubaker, E.; Cabrera-Palmer, B.; Cates, J.C.B.; Dorril, R.; Druetzler, A.; Elam, J.; Febbraro, M.; Feng, Patrick L.; Folsom, Michael W.; Gabella, G.; Galindo-Tellez, A.; Goldblum, B.; Hausladen, P.; Kaneshige, N.; Keffe, Kevin; Laplace, T.A.; Maggi, Paul; Mane, A.; Manfredi, J.; Marleau, P.; Mattingly, J.; Mishra, M.; Moustafa, A.; Nattress, J.; Nishimura, K.; Pinto-Souza, B.; Steele, J.; Takahashi, E.; Ziock, K.

Abstract not provided.

Single Volume Scatter Camera: Optically Segmented Effort - Single Slide Overview

Sweany, Melinda D.; Adamek, E.; Alhajaji, H.; Brown, James R.; Balathy, John; Brubaker, E.; Cabrera-Palmer, B.; Cates, J.C.B.; Dorril, R.; Druetzler, A.; Elam, J.; Febbraro, M.; Feng, Patrick L.; Folsom, Michael W.; Gabella, G.; Galindo-Tellez, A.; Goldblum, B.; Hausladen, P.; Kaneshige, N.; Keffe, Kevin; Laplace, T.A.; Maggi, Paul; Mane, A.; Manfredi, J.; Marleau, P.; Mattingly, J.; Mishra, M.; Moustafa, A.; Nattress, J.; Nishimura, K.; Pinto-Souza, B.; Steele, J.; Takahashi, E.; Ziock, K.

Abstract not provided.

Boron-loaded organic glass scintillators

Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Nguyen, Lucas; Gabella, Gino; Laplace, Thibault A.; Carlson, Joseph; Brubaker, E.; Feng, Patrick L.

Herein we report the progress towards an organic glass scintillator with fast and thermal neutron sensitivity providing “triple” pulse shape discrimination (PSD) through the inclusion of a boron-incorporated aromatic molecule. The commercially available molecule 2-(p-tolyl)-1,3,2-dioxaborinane (TDB) can be readily synthesized in one step using inexpensive materials and incorporated into the organic glass scintillator at 20% by weight or 0.25% 10B by mass. In addition, we demonstrate that TDB can be easily scaled up and formulated into organic glass scintillator samples to produce a thermal neutron capture signal with a light yield equivalent to 120.4 ± 3.7 keVee, which is the highest value reported in the literature to date.

More Details

The Single-Volume Scatter Camera

Manfredi, Juan; Adamek, Evan; Brown, Joshua; Brubaker, E.; Cabrera-Palmer, B.; Cates, Joshua; Dorrill, Ryan; Druetzler, Andrew; Elam, Jeff; Feng, Patrick L.; Folsom, Micah; Galindo-Tellez, Aline; Goldblum, Bethany; Hausladen, Paul; Kaneshige, Nathan; Keefe, Kevin P.; Laplace, Thibault; Learned, John; Mane, Anil; Marleau, P.; Mattingly, John; Mishra, Mudit; Moustafa, Ahmed; Nattress, Jason; Steele, J.; Sweany, Melinda D.; Weinfurther, Kyle J.; Ziock, Klaus-Peter

Abstract not provided.

The single-volume scatter camera

Proceedings of SPIE - The International Society for Optical Engineering

Manfredi, Juan J.; Adamek, Evan; Brown, Joshua A.; Brubaker, E.; Cabrera-Palmer, B.; Cates, Joshua; Dorrill, Ryan; Druetzler, Andrew; Elam, Jeff; Feng, Patrick L.; Folsom, Micah; Galindo-Tellez, Aline; Goldblum, Bethany L.; Hausladen, Paul; Kaneshige, Nathan; Keefe, Kevin P.; Laplace, Thibault A.; Learned, John G.; Mane, Anil; Marleau, P.; Mattingly, John; Mishra, Mudit; Moustafa, Ahmed; Nattress, Jason; Steele, J.; Sweany, Melinda D.; Weinfurther, Kyle J.; Ziock, Klaus P.

The multi-institution Single-Volume Scatter Camera (SVSC) collaboration led by Sandia National Laboratories (SNL) is developing a compact, high-efficiency double-scatter neutron imaging system. Kinematic emission imaging of fission-energy neutrons can be used to detect, locate, and spatially characterize special nuclear material. Neutron-scatter cameras, analogous to Compton imagers for gamma ray detection, have a wide field of view, good event-by-event angular resolution, and spectral sensitivity. Existing systems, however, suffer from large size and/or poor efficiency. We are developing high-efficiency scatter cameras with small form factors by detecting both neutron scatters in a compact active volume. This effort requires development and characterization of individual system components, namely fast organic scintillators, photodetectors, electronics, and reconstruction algorithms. In this presentation, we will focus on characterization measurements of several SVSC candidate scintillators. The SVSC collaboration is investigating two system concepts: the monolithic design in which isotropically emitted photons are detected on the sides of the volume, and the optically segmented design in which scintillation light is channeled along scintillator bars to segmented photodetector readout. For each of these approaches, we will describe the construction and performance of prototype systems. We will conclude by summarizing lessons learned, comparing and contrasting the two system designs, and outlining plans for the next iteration of prototype design and construction.

More Details

Effect of Teflon Wrapping on the Interaction Position Reconstruction Resolution in Long, Thin Plastic Scintillator Pillars

2020 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2020

Moustafa, Ahmed; Galindo-Tellez, Aline; Sweany, Melinda D.; Brubaker, E.; Mattingly, John

An optically-segmented single-volume scatter camera is being developed to image MeV-energy neutron sources. The design employs long, thin, optically isolated organic scintillator pillars with 5 mm × 5 mm × 200 mm dimensions (i.e., an aspect-ratio of 1:1:40). Teflon reflector is used to achieve optical isolation and improve light collection. The effect of Teflon on the ability to resolve the radiation interaction locations along such high aspect-ratio pillars is investigated. It was found that reconstruction based on the amplitude of signals collected on both ends of a bare pillar is less precise than reconstruction based on their arrival times. However, this observation is reversed after wrapping in Teflon, such that there is little to no improvement in reconstruction resolution calculated by combining both methods. It may be possible to use another means of optical isolation that does not require wrapping each individual pillar of the camera.

More Details

Current Status of an Optically-Segmented Single-Volume Scatter Camera for Neutron Imaging

Brown, J.A.; Brubaker, E.; Dorril, R.; Druetzler, A.; Elam, J.; Febbraro, M.; Feng, Patrick L.; Folsom, Michael W.; Galino-Tellez, A.; Goldblum, B.L.; Hausladen, P.; Kaneshige, N.; Keffe, K.; Laplace, T.A.; Learned, J.G.; Mane, A.; Manfredi, J.; Marleau, Peter; Mattingly, J.; Mishra; Almanza-Madrid, Rene A.; Moustafa, A.; Nattress, J.; Steele, J.; Sweany, Melinda D.; Weinfurther, K.; Ziock, K.

Abstract not provided.

Current status of an optically-segmented single-volume scatter camera for neutron imaging

Brown, Joshua; Brubaker, E.; Cabrera-Palmer, B.; Carlson, Joseph; Dorril, Ryan; Druetzler, Andrew; Elam, Jeff; Febbraro, Michael; Feng, Patrick L.; Folsom, Micah; Galino-Tellez, Aline; Goldblum, Bethany; Hausladen, Paul; Kaneshige, Nate; Keffe, Kevin; Laplace, Tibo; Learned, John; Mane, Anil; Manfredi, Juan; Marleau, P.; Mattingly, John; Mishra, Mudit; Moustafa, Ahmed; Nattress, Jason; Nishimura, Kurtis; Steele, J.; Sweany, Melinda D.; Ziock, Klaus

Abstract not provided.

Results 1–50 of 189