Frequency agile laser safety & hazard analysis for the Sandia Remote Sensing System LIDAR

Augustoni, Arnold L.

A laser safety and hazard analysis was performed for the Raytheon Frequency Agile Laser (FAL) to be used with the Sandia Remote Sensing System (SRSS) B-70 Trailer based on the 2007 version of the American National Standards Institute's (ANSI) Standard 136.1, for Safe Use of Lasers and the 2005 version of the ANSI Standard Z136.6, for Safe Use of Lasers Outdoors. The B-70 SRSS LIDAR system is a portable platform, which is used to perform laser interaction experiments and tests at various national test sites.

More Details

Updated laser safety & hazard analysis for the ARES laser system based on the 2007 ANSI Z136.1 standard

Augustoni, Arnold L.

A laser safety and hazard analysis was performed for the temperature stabilized Big Sky Laser Technology (BSLT) laser central to the ARES system based on the 2007 version of the American National Standards Institutes (ANSI) Standard Z136.1, for Safe Use of Lasers and the 2005 version of the ANSI Standard Z136.6, for Safe Use of Lasers Outdoors. The ARES laser system is a Van/Truck based mobile platform, which is used to perform laser interaction experiments and tests at various national test sites.

More Details

The probability of laser caused ocular injury to the aircrew of undetected aircraft violating the exclusion zone about the airborne aura LIDAR

Augustoni, Arnold L.

The probability of a laser caused ocular injury, to the aircrew of an undetected aircraft entering the exclusion zone about the AURA LIDAR airborne platform with the possible violation of the Laser Hazard Zone boundary, was investigated and quantified for risk analysis and management.

More Details

Hazard analysis of long term viewing of visible laser light off of fluorescent diffuse reflective surfaces (post-it)

Augustoni, Arnold L.

A laser hazard analysis is performed to evaluate if the use of fluorescent diffuse reflectors to view incident laser beams (Coherent Verdi 10W) present a hazard based on the ANSI Standard Z136.1-2000, American National Standard for the Safe Use of Lasers. The use of fluorescent diffuse reflectors in the alignment process does not pose an increased hazard because of the fluorescence at a different wavelength than that of the incident laser.

More Details

Laboratory measurement verification of laser hazard analysis for miles weapon simulators used in force on force exercises

Augustoni, Arnold L.

Due to the change in the batteries used with the Small Arm Laser Transmitters (SALT) from 3-volts dc to 3.6-volts dc and changes to SNL MILES operating conditions, the associated laser hazards of these units required re-evaluation to ensure that the hazard classification of the laser emitters had not changed as well. The output laser emissions of the SNL MILES, weapon simulators and empire guns, used in Force-On-Force (FOF) training exercises, was measured in accordance to the ANSI Standard Z136.4-2005, ''Recommended Practice for Laser Safety Measurements for Hazard Evaluation''. The laser hazard class was evaluated in accordance with the ANSI Standard Z136.1-2000, ''Safe Use of Lasers'', using ''worst'' case conditions associated with these MILES units. Laser safety assessment was conducted in accordance with the ANSI Standard Z136.6-2005, ''Safe Use of Lasers Outdoors''. The laser hazard evaluation of these MILES laser emitters was compared to and supersedes SAND Report SAND2002-0246, ''Laser Safety Evaluation of the MILES and Mini MILES Laser Emitting Components'', which used ''actual'' operating conditions of the laser emitters at the time of its issuance.

More Details

Safety and Hazard Analysis for the Coherent/Acculite Laser Based Sandia Remote Sensing System (Trailer B70)

Augustoni, Arnold L.

A laser safety and hazard analysis is presented, for the Coherent(r) driven Acculite(r) laser central to the Sandia Remote Sensing System (SRSS). The analysis is based on the 2000 version of the American National Standards Institute's (ANSI) Standard Z136.1, for Safe Use of Lasers and the 2000 version of the ANSI Standard Z136.6, for Safe Use of Lasers Outdoors. The trailer (B70) based SRSS laser system is a mobile platform which is used to perform laser interaction experiments and tests at various national test sites. The trailer based SRSS laser system is generally operated on the United State Air Force Starfire Optical Range (SOR) at Kirtland Air Force Base (KAFB), New Mexico. The laser is used to perform laser interaction testing inside the laser trailer as well as outside the trailer at target sites located at various distances. In order to protect personnel who work inside the Nominal Hazard Zone (NHZ) from hazardous laser exposures, it was necessary to determine the Maximum Permissible Exposure (MPE) for each laser wavelength (wavelength bands) and calculate the appropriate minimum Optical Density (ODmin) necessary for the laser safety eyewear used by authorized personnel. Also, the Nominal Ocular Hazard Distance (NOHD) and The Extended Ocular Hazard Distance (EOHD) are calculated in order to protect unauthorized personnel who may have violated the boundaries of the control area and might enter into the laser's NHZ for testing outside the trailer. 4Page intentionally left blank

More Details

Active polarimeter optical system laser hazard analysis

Augustoni, Arnold L.

A laser hazard analysis was performed for the SNL Active Polarimeter Optical System based on the ANSI Standard Z136.1-2000, American National Standard for Safe Use of Lasers and the ANSI Standard Z136.6-2000, American National Standard for Safe Use of Lasers Outdoors. The Active Polarimeter Optical System (APOS) uses a pulsed, near-infrared, chromium doped lithium strontium aluminum fluoride (Cr:LiSAF) crystal laser in conjunction with a holographic diffuser and lens to illuminate a scene of interest. The APOS is intended for outdoor operations. The system is mounted on a height adjustable platform (6 feet to 40 feet) and sits atop a tripod that points the beam downward. The beam can be pointed from nadir to as much as 60 degrees off of nadir producing an illuminating spot geometry that can vary from circular (at nadir) to elliptical in shape (off of nadir). The JP Innovations crystal Cr:LiSAF laser parameters are presented in section II. The illuminating laser spot size is variable and can be adjusted by adjusting the separation distance between the lens and the holographic diffuser. The system is adjusted while platform is at the lowest level. The laser spot is adjusted for a particular spot size at a particular distance (elevation) from the laser by adjusting the separation distance (d{sub diffuser}) to predetermined values. The downward pointing angle is also adjusted before the platform is raised to the selected operation elevation.

More Details

3rd Tech DeltaSphere-3000 Laser 3D Scene Digitizer infrared laser scanner hazard analysis

Augustoni, Arnold L.

A laser hazard analysis and safety assessment was performed for the 3rd Tech model DeltaSphere-3000{reg_sign} Laser 3D Scene Digitizer, infrared laser scanner model based on the 2000 version of the American National Standard Institute's Standard Z136.1, for the Safe Use of Lasers. The portable scanner system is used in the Robotic Manufacturing Science and Engineering Laboratory (RMSEL). This scanning system had been proposed to be a demonstrator for a new application. The manufacture lists the Nominal Ocular Hazard Distance (NOHD) as less than 2 meters. It was necessary that SNL validate this NOHD prior to its use as a demonstrator involving the general public. A formal laser hazard analysis is presented for the typical mode of operation for the current configuration as well as a possible modified mode and alternative configuration.

More Details

Laser hazard analysis for LASIRIS Model MAG-501L-670M-1000-45[degree]-K diode laser associated with high resolution pulsed scanner

Augustoni, Arnold L.

A laser hazard analysis and safety assessment was performed for the LASIRISTM Model MAG-501L-670M-1000-45o-K diode laser associated with the High Resolution Pulse Scanner based on the ANSI Standard Z136.1-2000, American National Standard for the Safe Use of Lasers and the ANSI Standard Z136.6-2000, American National Standard for the Safe Use of Lasers Outdoors. The laser was evaluated for both indoor and outdoor use.

More Details

Laser hazard analysis for various candidate diode lasers associated with the high resolution pulsed scanner

Augustoni, Arnold L.

A laser hazard analysis and safety assessment was performed for each various laser diode candidates associated with the High Resolution Pulse Scanner based on the ANSI Standard Z136.1-2000, American National Standard for the Safe Use of Lasers. A theoretical laser hazard analysis model for this system was derived and an Excel{reg_sign} spreadsheet model was developed to answer the 'what if questions' associated with the various modes of operations for the various candidate diode lasers.

More Details

The Long Range Reconnaissance and Observation System (LORROS) with the Kollsman, Inc. Model LH-40, Infrared (Erbium) Laser Rangefinder hazard analysis and safety assessment

Augustoni, Arnold L.

A laser hazard analysis and safety assessment was performed for the LH-40 IR Laser Rangefinder based on the 2000 version of the American National Standard Institute's Standard Z136.1, for the Safe Use of Lasers and Z136.6, for the Safe Use of Lasers Outdoors. The LH-40 IR Laser is central to the Long Range Reconnaissance and Observation System (LORROS). The LORROS is being evaluated by the Department 4149 Group to determine its capability as a long-range assessment tool. The manufacture lists the laser rangefinder as 'eye safe' (Class 1 laser classified under the CDRH Compliance Guide for Laser Products and 21 CFR 1040 Laser Product Performance Standard). It was necessary that SNL validate this prior to its use involving the general public. A formal laser hazard analysis is presented for the typical mode of operation.

More Details

Extended ocular hazard distances associated with intrabeam aided viewing of the Sandia remote sensing system, airborne aura laser (Big Sky Variant)

Augustoni, Arnold L.

A laser hazard analysis to determine the Extended Ocular Hazard Distances associated with a possible intrabeam aided viewing of the Sandia Remote Sensing System (SRSS) airborne AURA laser (Big Sky Laser Technology) was performed based on the 2000 version of the American National Standard Institute's (ANSI) Standard Z136.1, for the Safe Use of Lasers and the 2000 version of the ANSI Standard Z136.6, for the Safe Use of Lasers Outdoors. The AURA lidar system is installed in the instrument pod of a Proteus airframe and is used to perform laser interaction experiments and tests at various national test sites. The targets are located at various distances (ranges) from the airborne platform. Nominal Ocular Hazard Distance (NOHD) and maximum ''eye-safe'' dwell times for various operational altitudes associated with unaided intrabeam exposure of ground personnel were determined and presented in a previous SAND report. Although the target areas are controlled and the use of viewing aids are prohibited there is the possibility of the unauthorized use of viewing aids such as binoculars. This aided viewing hazard analysis is supplemental to the previous SAND report for the laser hazard analysis of the airborne AURA.

More Details

Laser selection based on maximum permissible exposure limits for visible and middle-near infrared repetitively pulsed lasers

Augustoni, Arnold L.

The Maximum Permissible Exposure (MPE) is central to laser hazard analysis and is in general a function of the radiant wavelength. The selection of a laser for a particular application may allow for flexibility in the selection of the radiant wavelength. This flexibility would allow the selection of a particular laser based on the MPE and the hazards associated with that radiant wavelength. The Calculations of the MPEs for various laser wavelength ranges are presented. Techniques for determining eye safe viewing distances for both aided and unaided viewing and the determination of flight hazard distances are presented as well.

More Details

Laser safety evaluation and output measurements for the VITAL -2 Variable Intensity Tactical Aiming Light (laser) used with the Proforce M-4 system in force-on-force exercises

Augustoni, Arnold L.; Augustoni, Arnold L.

A laser safety hazard evaluation and pertinent output measurements were performed (June 2003 through August 2003) on several VITAL-2 Variable Intensity Tactical Aiming Light--infrared laser, associated with the Proforce M-4 system used in force-on-force exercises. The VITAL-2 contains two diode lasers presenting 'Extended Source' viewing out to a range on the order of 1.3 meters before reverting to a 'Small Source' viewing hazard. Laser hazard evaluation was performed in concert with the ANSI Std. Z136.1-2000 for the safe use of lasers and the ANSI Std. Z136.6-2000 for the safe use of lasers outdoors. The results of the laser hazard analysis for the VITAL-2, indicates that this Tactical Aiming IR laser presents a Class 1 laser hazard to personnel in the area of use. Field measurements performed on 71 units confirmed that the radiant outputs were at all times below the Allowable Emission Limit and that the irradiance of the laser spot was at all locations below the Maximum Exposure Limit. This system is eye-safe and it may be used under current SNL policy in force-on-force exercises. The VITAL-2 Variable Intensity Tactical Aiming Light does not present a laser hazard greater than Class 1, to aided viewing with binoculars.

More Details

Laser hazard analysis for airborne AURA (Big Sky variant) Proteus platform

Augustoni, Arnold L.; Augustoni, Arnold L.

A laser safety and hazard analysis was performed for the airborne AURA (Big Sky Laser Technology) lidar system based on the 2000 version of the American National Standard Institute's (ANSI) Standard Z136.1, for the Safe Use of Lasers and the 2000 version of the ANSI Standard Z136.6, for the Safe Use of Lasers Outdoors. The AURA lidar system is installed in the instrument pod of a Proteus airframe and is used to perform laser interaction experiments and tests at various national test sites. The targets are located at various distances or ranges from the airborne platform. In order to protect personnel, who may be in the target area and may be subjected to exposures, it was necessary to determine the Maximum Permissible Exposure (MPE) for each laser wavelength, calculate the Nominal Ocular Hazard Distance (NOHD), and determine the maximum 'eye-safe' dwell times for various operational altitudes and conditions. It was also necessary to calculate the appropriate minimum Optical Density (ODmin) of the laser safety eyewear used by authorized personnel who may receive hazardous exposures during ground base operations of the airborne AURA laser system (system alignment and calibration).

More Details

Laser safety and hazard analysis for the temperature stabilized BSLT ARES laser system

Augustoni, Arnold L.; Augustoni, Arnold L.

A laser safety and hazard analysis was performed for the temperature stabilized Big Sky Laser Technology (BSLT) laser central to the ARES system based on the 2000 version of the American National Standards Institute's (ANSI) Standard Z136.1, for Safe Use of Lasers and the 2000 version of the ANSI Standard Z136.6, for Safe Use of Lasers Outdoors. As a result of temperature stabilization of the BSLT laser the operating parameters of the laser had changed requiring a hazard analysis based on the new operating conditions. The ARES laser system is a Van/Truck based mobile platform, which is used to perform laser interaction experiments and tests at various national test sites.

More Details

Laser Safety Audit and Inventory System Database

Augustoni, Arnold L.; Augustoni, Arnold L.

A laser safety auditing and inventory system has been in use at Sandia National Laboratories--Albuquerque for the past five years and has recently been considered for adoption by Sandia National Laboratories--Livermore. The system utilizes the ''Microsoft Access'' database application, part of the Office 2000 software package. Audit and inventory data is available on-line for ready access by laser users. Data is updated weekly to provide users with current information relating to laser facility audits and laser inventories.

More Details

Laser Hazard Analysis for Ultra-Fast Sub-Nanosecond, Mode-Locked Near Infrared Lasers Operated with Pulse Repetition Frequencies Above the Critical Frequency

Augustoni, Arnold L.; Augustoni, Arnold L.

Ultra fast, sub-nanosecond (picosecond to femtosecond) duration, laser pulses present unique challenges when performing laser safety analysis involving mode-locked lasers, which operate at pulse repetition frequencies above the critical frequency in the near infrared wavelength bands. Two specific cases are presented, one such case that agrees and one that disagrees with the general rule on critical frequency. The results show that in all cases the appropriate maximum permissible exposure is always the smallest of the values calculated from ANSI rule 1, 2 and 3.

More Details

Laser Safety and Hazard Analysis for the Trailer (B70) Based AURA Laser System

Augustoni, Arnold L.

A laser safety and hazard analysis was performed for the AURA laser system based on the 2000 version of the American National Standards Institute's (ANSI) Standard Z136.1, for ''Safe Use of Lasers'' and the 2000 version of the ANSI Standard Z136.6, for ''Safe Use of Lasers Outdoors''. The trailer based AURA laser system is a mobile platform, which is used to perform laser interaction experiments and tests at various national test sites. The trailer (B70) based AURA laser system is generally operated on the United State Air Force Starfire Optical Range (SOR) at Kirtland Air Force Base (KAFB), New Mexico. The laser is used to perform laser interaction testing inside the laser trailer as well as outside the trailer at target sites located at various distances from the exit telescope. In order to protect personnel, who work inside the Nominal Hazard Zone (NHZ), from hazardous laser emission exposures it was necessary to determine the Maximum Permissible Exposure (MPE) for each laser wavelength (wavelength bands) and calculate the appropriate minimum Optical Density (OD{sub min}) of the laser safety eyewear used by authorized personnel and the Nominal Ocular Hazard Distance (NOHD) to protect unauthorized personnel who may have violated the boundaries of the control area and enter into the laser's NHZ.

More Details

Laser Safety and Hazardous Analysis for the ARES (Big Sky) Laser System

Augustoni, Arnold L.

A laser safety and hazard analysis was performed for the ARES laser system based on the 2000 version of the American National Standards Institute's (ANSI) Standard Z136.1,for Safe Use of Lasers and the 2000 version of the ANSI Standard Z136.6, for Safe Use of Lasers Outdoors. The ARES laser system is a Van/Truck based mobile platform, which is used to perform laser interaction experiments and tests at various national test sites.

More Details

Laser Safety Evaluation of the Oscmar M203PI Grenade Launcher Simulator (GLS) and the Associated Umpire Control Gun

Augustoni, Arnold L.

A laser safety evaluation and pertinent output measurements were performed (during March and April 2002) on the M203PI Grenade Launcher Simulator (GLS) and its associated Umpire Control Gun manufactured by Oscmar International Limited, Auckland, New Zealand. The results were the Oscmar Umpire Gun is laser hazard Class 1 and can be used without restrictions. The radiant energy output of the Oscmar M203PI GLS, under ''Small Source'' criteria at 10 centimeters, is laser hazard Class 3b and not usable, under SNL policy, in force-on-force exercises. However, due to a relatively large exit diameter and an intentionally large beam divergence, to simulate a large area blast, the output beam geometry met the criteria for ''Extended Source'' viewing [ANSI Std. 2136.1-2000 (S.l)]. Under this ''Extended Source'' criteria the output of the M203PI GLS unit was, in fact, laser hazard Class 1 (eye safe), for 3 of the 4 possible modes of laser operation. The 4'h mode, ''Auto Fire'', which simulates a continuous grenade firing every second and is not used at SNL, was laser hazard Class 3a (under the ''Extended Source'' viewing criteria). The M203PI GLS does present a laser hazard Class 3a to aided viewing with binoculars inside 3 meters from the unit. Farther than 3 meters it is ''eye safe''. The M203PI GLS can be considered a Class 1 laser hazard and can be used under SNL policy with the following restrictions: (1) The M203PI GLS unit shall only be programmed for: the ''Single Fire'' (which, includes ''Rapid Fire'') and the ''Auto Align'' (used in adjusting the alignment of the grenade launcher simulator system to the target) modes of operation. (2) The M203PI GLS shall never be directed against personnel, using binoculars, inside of 3 meters. DOE Order 5480.16A, Firearms Safety, (Chapter 1)(5)(a)(8)(d) and DOE-STD-1091-96, Firearms Safety (Chapter 4); already prevents ESS laser engagement of personnel (with or without binoculars), ''closer than 10 feet (3.05 meters)''. Both of these restrictions can be administratively imposed, through a formal Operating Procedure or Technical Work Document and by full compliance with DOE orders and standards.

More Details

Laser Safety Evaluation of the MILES and Mini MILES Laser Emitting Components

Augustoni, Arnold L.

Laser safety evaluation and output emission measurements were performed (during October and November 2001) on SNL MILES and Mini MILES laser emitting components. The purpose, to verify that these components, not only meet the Class 1 (eye safe) laser hazard criteria of the CDRH Compliance Guide for Laser Products and 21 CFR 1040 Laser Product Performance Standard; but also meet the more stringent ANSI Std. z136.1-2000 Safe Use of Lasers conditions for Class 1 lasers that govern SNL laser operations. The results of these measurements confirmed that all of the Small Arms Laser Transmitters, as currently set (''as is''), meet the Class 1 criteria. Several of the Mini MILES Small Arms Transmitters did not. These were modified and re-tested and now meet the Class 1 laser hazard criteria. All but one System Controllers (hand held and rifle stock) met class 1 criteria for single trigger pulls and all presented Class 3a laser hazard levels if the trigger is held (continuous emission) for more than 5 seconds on a single point target. All units were Class 3a for ''aided'' viewing. These units were modified and re-tested and now meet the Class 1 hazard criteria for both ''aided'' as well as ''unaided'' viewing. All the Claymore Mine laser emitters tested are laser hazard Class 1 for both ''aided'' as well as ''unaided'' viewing.

More Details